3 May 2022 in IEEE Transactions on Power Delivery
The faults of electrical equipment are mainly generated by electrical and mechanical defects, which are usually detected by external ultrasonic and vibration sensors respectively. To improve the accuracy and efficiency of the diagnosis, a novel ultrasound-vibration composite sensor(UVCS) which can detect ultrasound and vibration acceleration signals synchronously at the same place, is proposed and developed scientifically in this paper. The working principle of UVCS is based on the combination of the mass and the backing as well as the steel base and matching layer, and the structure is improved reasonably. Furthermore, the ultrasound and vibration signals can be separated by filtering. In addition, the test results on a 110kV GIS show the high precision and reliability of UVCS and illustrate the superiority in practical application.
28 February 2019 in IEEE Transactions on Applied Superconductivity
23 November 2018 in IEEE Transactions on Applied Superconductivity
8 September 2022 in IEEE Transactions on Dielectrics and Electrical Insulation
Oscillating lightning impulse (OLI) voltage is recommended for on-site testing due to its high generation efficiency. In this paper, partial discharge (PD) characteristics under field impulse voltage waveforms are investigated. The experiment is carried out on a scaled transformer model with a protrusion defect inside as the PD source. Both oscillating and standard lightning impulse (SLI) voltages are acquired as test waveforms. Main discharges and reverse discharges are detected simultaneously under both OLI and SLI voltage. The increasing applied voltage amplitude advances the main discharge and enlarges its amplitude, and it also prolongs the duration of the reverse discharge and increases the number. The amplitude of main discharge is related to the PD voltage, while that of reverse discharge depends on the dynamic variation of the impulse voltage. Since OLI voltage contains multiple rising edges during the oscillation period, more PDs are excited. Disruptive effect (DE) model is extended for PD analysis to show the oscillation effect on PD distribution. The OLI test with PD measurement performed on a 220 kV transformer proves that PD detection during impulse voltage withstand test reflects more detailed information that can be used for early diagnosis of power transformers.
10 December 2018 in IEEE Transactions on Applied Superconductivity
The electrical insulation performance of dielectric materials is an important parameter in the insulation design of cold dielectric (CD) high-temperature superconducting (HTS) cable. PPLP (Polypropylene laminated paper) and Kraft paper are suitable for insulation design of CD HTS cable. The experimental study on the cryogenic insulation properties of PPLP and Kraft paper at 0.1 MPa liquid nitrogen were carried out, and dielectric strength of mini-model cable which were assembled as the same structure with CD HTS cable in DC breakdown, lightning impulse breakdown and AC breakdown were obtained according to the three-parameter Weibull distribution based on grey model GM(1,1). The results have important practical value for the insulation design of CD HTS cable.
26 August 2022 in Energy Reports