Kaori Futaba

Kaori Futaba

Auto-generated profile, based on publicly available information

Kaori Futaba

Department of Surgery, The Chinese University of Hong Kong, Shatin, Hong Kong

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2021 in Journal of Advanced Research
Verified
Journal Article
Open access
DSDaming Sun
Daming Sun
DLDonghua Liao
Donghua Liao
SCSsu Chi Chen
Ssu Chi Chen
CWCherry Wong
Cherry Wong
WLWing Wah Leung
Wing Wah Leung
HGHans Gregersen
Hans Gregersen
Defecation is a complex process that is difficult to study and analyze. Here, we present new analytical tools to calculate frictional force and tension during expulsion of the Fecobionics simulated stool in human subjects. The 12-cm-long Fecobionics device contained pressure sensors, motion processor units for measurement of orientation and bending, and impedance rings for measurement of cross-sectional areas. Eight normal subjects defecated Fecobionics. The bending angle of the device, frictional force between the device and the surrounding tissue, and the stretch tensions were calculated. The bending angle and pressures changed during expulsion with the maximum pressure recorded at the rear. The averaged circumferential tension, longitudinal tension and friction force in each subject were associated with the front-rear pressure difference (r > 0.7, p < 0.005). The peak circumferential tension, longitudinal tension, and friction force immediately before expulsion of the rear were significantly higher compared to when the front entered the anal canal (F = 164.7, p < 0.005; F = 152.1, p < 0.005; F = 71.4, p < 0.005; respectively.). This study shows that Fecobionics obtained reliable data under physiological conditions. Mechanical features such as frictional force and stretch tensions were assessable during Fecobionics expulsion.

2 August 2019 in Journal of Biomechanical Engineering
Verified
Journal Article
Open access
PDF file
DLDonghua Liao
Donghua Liao
SCS. C. Chen
S. C. Chen
KLK. M. Lo
K. M. Lo
JZJ. Zhao
J. Zhao
KFK. Futaba
K. Futaba
HGHans Gregersen
Hans Gregersen
A mechanical approach is needed for understanding anorectal function and defecation. Fecal continence is achieved by several interacting mechanisms including anatomical factors, anorectal sensation, rectal compliance, stool consistency, anal muscle strength, motility, and psychological factors. The balance is easily disturbed, resulting in symptoms such as fecal incontinence and constipation. Novel technologies have been developed in recent years for studying anorectal function. Especially, the Fecobionics device, a simulated feces, has gained attention recently. This facilitates new analysis of anorectal mechanical function. In this study, a theoretical model is developed to analyze anorectal mechanophysiological data generated by the Fecobionics device. Theoretical approaches can enhance future interdisciplinary research for unraveling defecatory function, sensory-motor disorders, and symptoms. This is a step in the direction of personalized treatment for gastrointestinal disorders based on optimized subtyping of anorectal disorders.

8 March 2022 in Asian Journal of Endoscopic Surgery
Verified
Journal Article
Closed access
MHMan fung HO
Man fung HO
KFKaori Futaba
Kaori Futaba
TMTony Wing Chung Mak
Tony Wing Chung Mak
SNSimon SM Ng
Simon SM Ng

1 April 2021 in Clinical and Translational Gastroenterology
Verified
Journal Article
Open access
ZZZ. Zhuang
Z. Zhuang
HHH.Y. Hung
H.Y. Hung
SCS.C. Chen
S.C. Chen
KFK. Futaba
K. Futaba
HGHans Gregersen
Hans Gregersen
INTRODUCTION: Perineal descent is a phenomenon associated with anorectal dysfunction. It is diagnosed by defecography but subjected to manual measurements on the images/videos and interobserver bias. Fecobionics is a simulated feces for assessing important physiological parameters during defecation. Here, we translate Fecobionics into a new method for estimation of perineal descent based on electronic signals from the embedded inertial measurement units (IMUs). METHODS: A displacement measurement method by a combined zero-velocity update and gravity compensation algorithm from IMUs was developed. The method was verified in a robot model, which mimicked perineal descent motion. RESULTS: The method correlated well with the reference (R2 = 0.9789) and had a deviation from the peak displacement (range 0.25–2.5 cm) of −0.04 ± 0.498 cm. The method was further validated in 5 human experiments with comparison to the benchmark defecography technology (R2 = 0.79). DISCUSSION: The proposed technology is objective, i.e., electronic measurements rather than by fluoroscopy or MRI. The development may impact clinical practice by providing a resource-saving and objective technology for diagnosing perineal descent in the many patients suffering from anorectal disorders. The technology may also be used in colon experiments with Fecobionics and for other gastrointestinal devices containing IMUs such as ingestible capsules like the Smartpill.

1 April 2022 in Clinical and Translational Gastroenterology
Verified
Journal Article
Open access
KFKaori Futaba
Kaori Futaba
SCSsu-Chi Chen
Ssu-Chi Chen
WLWing Wa Leung
Wing Wa Leung
YWYee Ni Wong
Yee Ni Wong
TMTony Mak
Tony Mak
HGHans Gregersen
Hans Gregersen
INTRODUCTION: Biofeedback therapy (BFT) is a well-known treatment for functional anorectal disorders. The effect of BFT was monitored in fecal incontinence (FI) patients with the Fecobionics test and with the conventional technologies, anorectal manometry (ARM) and balloon expulsion test (BET). METHODS: Studies were performed in 12 patients before and after 8 weeks of biofeedback training. The Fecal Incontinence Severity Index (FISI) score was obtained. Anal resting and squeeze pressures were measured before the bag was distended in the rectum until urge to defecate. Pressure recordings were made during Fecobionics evacuation. RESULTS: BFT resulted in 24% reduction in FISI scores (P < 0.01). Seven patients were characterized as responders. Anal pressures, the urge-to-defecate volume, and defecatory parameters did not change significantly during BFT. For ARM-BET, the maximum anal squeeze pressure, the urge-to-defecate volume, and the expulsion time were lower after BFT compared with those before BFT (P < 0.05). For Fecobionics, the change in urge volume (r = 0.74, P < 0.05) and the change in defecation index (r = 0.79, P < 0.01) were associated with the change in FISI score. None of the ARM-BET parameters were associated with the change in FISI score. It was studied whether any pre-BFT data could predict treatment success. The Fecobionics expulsion duration and the defecation index predicted the outcome (P < 0.05). The defecation index had a sensitivity of 100% and a specificity of 72%. None of the ARM-BET parameters predicted the outcome (all P > 0.2). DISCUSSION: Fecobionics was used as a tool to monitor the effect of BFT and proved better than conventional technologies for monitoring and predicting the outcome in the FISI score.