5 April 2021 in IEEE Electron Device Letters
This paper describes a recent activity in the development of a high-power microwave source based on a modified relativistic backward wave oscillator that is driven by an advanced version of a SINUS-family accelerator using a double-width pulse-forming line insulated with a modern synthetic oil. The relatively compact source of microwave pulses (0.6 GW, 20 ns, 9.4 GHz) can operate at a 100 pps repetition rate in a batch mode with batches of duration up to 15 s. The long-term stability of the oscillator performances during 106 pulses was achieved due to the improved conditions for explosive emission of the graphite cathode and the use of a titanium slow wave structure. Both factors prevented the shortening of the microwave pulses. With a proper choice of the magnetic field strength and longitudinal distribution and of the position of the resonant reflector, the pulse-to-pulse deviation of the microwave power was reduced with sacrifice in efficiency, which decreased from a simulated maximum efficiency of 44% to 40% in the simulation and to 35 ± 4% in the experiment. At an accelerating voltage of 418 kV and a magnetic induction of 0.64 T at the cathode, the standard deviation of the microwave pulsed power could be close to the voltage deviation.
24 July 2015 in Instruments and Experimental Techniques
The design of L-S-band and X-band microwave calorimeters with an ethanol-based working fluid is described. The calorimeters are automatically controlled and have an improved wide-aperture load that absorbs microwave radiation.
30 October 2020 in IEEE Transactions on Instrumentation and Measurement
The design of a liquid calorimeter with a closed absorbing load for measuring the energy of high-power microwave pulses in the range of 8–38 GHz is described. The calorimeter was designed to measure the energy of microwave pulses ranging from 1 to 500 J at a nominal power level of about 500 MW. The calorimeter includes a waveguide absorbing load and an automated control system. The waveguide absorbing load includes a segment of a circular overmoded cylindrical waveguide, the cylindrical wall is made of a dielectric pipe. The volume between the waveguide and the outer casing made of duralumin is filled with ethyl alcohol. Inside the waveguide there is a cone made of duralumin, providing the best matching of the load. The automated control system includes a control and registration unit, an algorithm for determining the meniscus position, a power supply, a program that runs directly on the calorimeter control unit and a control program for personal computer.
1 June 2024 in Instruments and Experimental Techniques
The possibility of using modern energy-intensive storage devices based on supercapacitors in relation to the tasks of powering magnetic systems of high-power microwave generators based on a relativistic backward wave tube (BWT) is described. Magnetic systems of such generators consist of a two-section solenoid. During the operation of the generator, a current of up to 700 A flows through the windings of a solenoid for few seconds. The magnetic system is powered from a capacitive storage device based on supercapacitor modules through step-down current regulators. Current stabilization is carried out by increasing the duration of the open state of the switches as the storage device is discharged. The control system contains a microprocessor that controls the power switches of current regulators as well as the management of the drive charging processes and interaction with peripheral devices. The work presents all the necessary formulas for calculating the parameters of the current regulator and estimating the storage capacity and its energy characteristics. Also, two variations for the implementation of similar power supplies are presented: the maximum output power of the first one is 280 kW with an output current duration of up to 1.5 s, and the maximum output power of the second one is 90 kW with an output current duration of up to 2.5 s.
13 April 2026 in Bulletin of Siberian Medicine
The authors of this lecture performed a comprehensive analysis of possible mechanisms for stimulating reparative processes after thermal skin damage using nanosecond repetitive pulsed microwave (RPM) radiation. The study analyzes both thermal and non-thermal mechanisms of the biological action of electromagnetic radiation, with special emphasis on the molecular aspects of the effects of nanosecond microwave pulses. Special attention is paid to the role of membrane proteins, calcium-dependent signaling pathways, and extracellular matrix components in realizing the regenerative potential of low-intensity microwave exposure. The study reveals the complex relationships between the physical parameters of RPM radiation (intensity, frequency, duration of pulses) and the activation of key cellular processes that ensure accelerated healing without scarring. The work uses experimental data obtained on models of burn injuries in laboratory animals (Wistar rats) using spectrophotometric, hematological, and histological methods. RPM radiation is a promising physical factor for stimulating skin regeneration, acting through non-thermal mechanisms. The combination of RPMs with cell therapy and pharmacological agents can become the basis of new protocols for the treatment of burns and other skin injuries. Further research is aimed at developing personalized treatment regimens, taking into account phases of the injury.
23 December 2024 in Engineering Technologies and Systems
Introduction. The magnetic systems of high power microwave generators, such as relativistic reverse wave lamps and klystrons, are powered with a direct current of up to 1 000 A from supercapacitor storage for several seconds. When designing power supplies for these magnetic systems, there is always necessary to determine the energy characteristics of the storage device. The analytical calculation of the characteristics is difficult, because of dynamic changes in some parameters of the magnetic system and storage device during current flow.Aim of the Study. The aim of the article is to create and experimentally test a mathematical model describing the process of powering a multi-section magnetic system with direct current from a supercapacitor storage device.Materials and Methods. The simulation takes into account the dynamic changes in the magnetic system parameters when current flows. The supercapacitor storage device is represented as a simple RC-circuit, the parameters of which are the nameplate data of its capacitance and internal resistance. The description of a storage device discharge process is based on the energy balance data. This model is implemented in the National Instruments LabView 2012 software package and has a user-friendly graphical interface. The simulation results were tested on equipment consisting of a power supply based on a supercapacitor storage device and two-section magnetic system.Results. The simulation results showed a good agreement with the experimental ones. According to the experiment results, the waveform of the current and voltage of the storage device, and the maximum duration of current stabilization were close to the simulation results. At the same time, the nameplate data of the capacity and internal resistance of the storage device characterize well its real parameters, taking into account the peculiarities of working together with the current regulator and the pulsed nature of energy consumption.Discussion and Conclusion. The slight difference in the results is explained by the deviation of the actual parameters of the storage device from its passport data and by the difference in the temperature of the windings used in the experiment and simulation. The calculation of the energy characteristics of the storage device is performed on the basis of the energy balance, which allows scaling the load through adding any number of energy consumers with independent current stabilization in each.