Sergey Vladimirov

Sergey Vladimirov

Auto-generated profile, based on publicly available information

Sergey Vladimirov

Meshalkin National Medical Research Center

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 March 2023 in Patologiya krovoobrashcheniya i kardiokhirurgiya
Verified
Journal Article
Open access
PDF file
ASAldar Shadanov
Aldar Shadanov
IZIrina Y. Zhuravleva
Irina Y. Zhuravleva
LSL.M. Samoylova
L.M. Samoylova
TTT.P. Timchenko
T.P. Timchenko
SVS.V. Vladimirov
S.V. Vladimirov
АCАлександр Михайлович Chernyavskiy
Александр Михайлович Chernyavskiy
Background: Vascular graft infection is a severe cardiovascular complication with high mortality rates. Antibacterial vascular graft coatings are widely used and continue to be improved.Objective: To develop a sealant with antimicrobial effect for Dacron vascular grafts and experimentally test the coating properties.Methods: We used 2 types of vascular grafts: graft No. 1 (plain weave) with initial water permeability of 78.8 ± 2.7 mL/cm2/min and graft No. 2 (2/1 twill + 6/4 satin weave) with water permeability of 549.8 ± 20.7 mL/cm2/min. We developed an original gelatin impregnation technique, tested it using a scanning electron microscopy, and measured water permeability and kink radius. We evaluated the antibacterial activity of vancomycin and gelatin impregnation by the disk diffusion test using media with Staphylococcus aureus ATCC 29213 and Enterococcus faecalis ATCC 29212 and measured inhibition zones after 24-hour incubation. We used samples cut out of grafts with vancomycin-containing (experimental group) and no vancomycin-containing (control group) impregnation.Results: The gelatin coating of the samples is visualized as a thin even film and provides zero water permeability. On the negative side, it increased stiffness and the kink radius. Thanks to vancomycin added to the coating, bacterial growth significantly inhibits: the mean diameter of the growth inhibition zone for Staphylococcus aureus and Enterococcus faecalis was 15.60 ± 0.65 and 14.40 ± 0.66 mm, respectively. The grafts untreated with vancomycin showed no growth inhibition zones.Conclusion: Vascular graft treatment with gelatin impregnation and vancomycin solution is a simple measure to prevent the growth of gram-positive bacteria on vascular grafts. Received 14 November 2022. Revised 15 December 2022. Accepted 19 December 2022. Funding: The work was supported by Russian Science Foundation (project No. 22-15-20005). Conflict of interest: The authors declare no conflict of interest. Contribution of the authorsConception and study design: I.Yu. Zhuravleva, A.A. Shadanov, D.A. SirotaData collection and analysis: A.A. Shadanov, L.M. Samoylova, S.V. Vladimirov, T.P. Timchenko, N.E. Luchnikov, E.V. KarpovaStatistical analysis: A.A. ShadanovDrafting the article: A.A. Shadanov, L.M. Samoylova, T.P. Timchenko, A.G. EdemskiyCritical revision of the article: D.A. Sirota, I.Yu. Zhuravleva, A.V. Bogachev-Prokofiev, A.M. ChernyavskiyFinal approval of the version to be published: A.A. Shadanov, I.Yu. Zhuravleva, L.M. Samoylova, T.P. Timchenko, S.V. Vladimirov, E.V. Karpova, N.E. Luchnikov, D.A. Sirota, A.G. Edemskiy, A.V. Bogachev-Prokofiev, A.M. Chernyavskiy

8 November 2024 in Patologiya krovoobrashcheniya i kardiokhirurgiya
Verified
Journal Article
Open access
PDF file
ISI.A. Soynov
I.A. Soynov
KRK.A. Rzaeva
K.A. Rzaeva
SMS.N. Manukian
S.N. Manukian
SVS.V. Vladimirov
S.V. Vladimirov
ADAnna Dokuchaeva
Anna Dokuchaeva
ЮКЮ.ю. Кулябин
Ю.ю. Кулябин
Introduction: Reconstruction of the right ventricular outflow tract is recommended for 20% of patients with congenital heart defects. The risks of complications during repeated open cardiac surgeries stimulated the implantation of the pulmonary artery valve according to the P. Bonhoeffer method developed more than 20 years ago. Modern transcatheter technologies enable implantation of the pulmonary artery valve in patients after transannular plastic surgery in combination with pulmonary regurgitation and not only when using biological valve conduits. Objective: The aim of this study was to evaluate the short- and mid-term outcomes of implanting a prototype of a self-expanding, transcatheter pulmonary artery valve in an experimental pig model. This study assesses the efficacy and safety of the novel device in comparison to traditional surgical methods. Methods: A total of 8 experimental animals were included in this study. The object of the study was a transcatheter self-expandable valve-containing prosthetic device designed for implantation in the pulmonary artery, which consisted of an external supporting mesh scaffold made of a titanium nickelide as well as sheathing and a leaflet mechanism. Results: In the early postoperative period, there was a minor complication in the form of a 1.5 cm small paraprosthetic fistula, which spontaneously closed in the long-term. No mortality or other complications were observed in the mid-term follow-up period. We also noted an insignificant increase in transvalvular gradients, with a gradient of 11 (8-13) mm Hg after surgery, and 16 (12-19) mm Hg in 6 months, p = 0.79. Upon removal animals from the experiment, the supporting scaffolds of the valves were intact without any damage. The valve surface was smooth, without traces of blood clots or cellular infiltration. Microscopically, there was no evidence of structural injuries and no signs of calcification after von Kossa staining. Conclusion: The experimental transcatheter-implanted valve demonstrated good short- and mid-term efficacy without significant pulmonary insufficiency signs and pressure gradient on the bioprosthesis. However, the fracture of the radial arches in the crown of the device, which occurred in 25% of cases, attests the demand on creating a more durable structure through reinforcement of rigidity or increasing the number of radial arches. Received 27 September 2024. Revised 24 October 2024. Accepted 25 October 2024. FundingThe research was carried out within the framework of the state assignment of the Ministry of Health of the Russian Federation (No. 124022500251-0). Conflict of interestThe authors declare no conflict of interest. Contribution of the authorsConception and study design: I.A. Soynov, K.A. Rzaeva, S.N. Manukian, S.V. Vladimirov, A.A. DokuchaevaData collection and analysis: A.V. Gorbatykh, N.R. Nichai, E.N. Amansahatova, Yu.Yu. Kulyabin, S.A. MagbulovaStatistical analysis: I.Yu. Zhuravleva, I.A. Soynov, K.A. Rzaeva, S.N. Manukian, S.V. Vladimirov, A.A. DokuchaevaDrafting the article: I.A. Soynov, K.A. Rzaeva, S.N. Manukian, S.V. Vladimirov, A.A. Dokuchaeva, A.V. Gorbatykh, N.R. NichaiCritical revision of the article: I.Yu. Zhuravleva, A.A. Dokuchaeva, A.V. Gorbatykh, N.R. NichaiFinal approval of the version to be published: I.A. Soynov, K.A. Rzaeva, S.N. Manukian, S.V. Vladimirov, A.A. Dokuchaeva, A.V. Gorbatykh, N.R. Nichai, E.N. Amansahatova, Yu.Yu. Kulyabin, S.A. Magbulova, I.Yu. Zhuravleva

30 August 2024 in Patologiya krovoobrashcheniya i kardiokhirurgiya
Verified
Journal Article
Open access
PDF file
ASAldar Shadanov
Aldar Shadanov
АCАлександр Михайлович Chernyavskiy
Александр Михайлович Chernyavskiy
DSD.A. Sirota
D.A. Sirota
MLM.M. Lyashenko
M.M. Lyashenko
SVS.V. Vladimirov
S.V. Vladimirov
IZIrina Y. Zhuravleva
Irina Y. Zhuravleva
Introduction: The development of a new generation of hybrid prostheses is a way to improve the results of surgical treatment of combined lesions of the aortic arch and descending aorta. Objective: The study was aimed to evaluate the biocompatibility of the new branched hybrid stent graft.Methods: The developed hybrid stent graft consisted of two parts including the vascular part and the stent graft part, which were supplemented with a stented branch for reconstruction of the left subclavian artery. To assess the biological compatibility, a stent graft was implanted in the descending thoracic aorta in 25 large pigs. The results were assessed by surgical mortality, postoperative complications, selective aortic angiography and histological examination after 6 month follow up period.Results: Implantation of a hybrid stent graft was successful in all cases, without complications. In the early period, 3 animals died. The causes of animal death were respiratory failure caused by lung barotrauma, intraoperative bleeding and sudden cardiac death. The remaining pigs survived until the end of the follow up period without complications and were subsequently withdrawn from the experiment. The duration of perfusion by carotid-femoral bypass surgery was 55 [50; 60] minutes. The volume of blood sweating through the vascular part of the prosthesis was 2.28 ± 0.23 ml/cm2/min; the blood loss for the first hour through drain tube was approximately 70.2 ± 8.9 ml. In 6 months after surgery the aortic angiography showed that the main body and branches of the hybrid stent graft were completely passable. No migration, deformation or endolics were observed. The analysis of histological sections showed the presence of a confluent layer of neointima continuously and evenly distributed throughout the luminal surface of the conduits, including lateral branchlets and anastomoses. The neointima was hyperplasized and represented by layers of unidirectional fibroblast cells, its luminal surface was covered with a layer of endotheliocytes. Conclusion: These results demonstrate the technical feasibility and safety of using a new hybrid stent graft with an additional stented branch. Received 16 July 2024. Revised 1 August 2024. Accepted 15 August 2024. FundingThe study was carried out within the framework of project No. 22-15-20005 (agreement No. 22-15-20005 with the Russian Science Foundation, dated 22.03.2022, agreement No. р-12 with the Ministry of Science and Innovation Policy of the Novosibirsk Region, dated 13.03.2023). Conflict of interestThe authors declare no conflict of interest. Contribution of the authorsConception and study design: A.M. Chernyavskiy, I.Yu. Zhuravleva, D.A. Sirota, A.A. ShadanovData collection and analysis: A.A. Shadanov, D.A. Sirota, M.M. Lyashenko, S.V. Vladimirov, T.P. Timchenko, A.A. Dokuchaeva, V.P. Borodin, A.K. Sabetov, D.V. Khomushku, M.N. Murtazaliev, Ya.L. Rusakova, E.V. KuznetsovaStatistical analysis: A.A. ShadanovDrafting the article: A.A. Shadanov, D.A. SirotaCritical revision of the article: I.Yu. Zhuravleva, D.A. Sirota, A.M. ChernyavskiyFinal approval of the version to be published: A.A. Shadanov, A.M. Chernyavskiy, D.A. Sirota, M.M. Lyashenko, S.V. Vladimirov, T.P. Timchenko, A.A. Dokuchaeva, V.P. Borodin, A.K. Sabetov, D.V. Khomushku, M.N. Murtazaliev, Ya.L. Rusakova, E.V. Kuznetsova, I.Yu. Zhuravleva

10 July 2024 in Siberian Journal of Clinical and Experimental Medicine
Verified
Journal Article
Open access
PDF file
AVA. V. Voitov
A. V. Voitov
SMS. N. Manukian
S. N. Manukian
SVS. V. Vladimirov
S. V. Vladimirov
VBV. P. Borodin
V. P. Borodin
EKE. Kobelev
E. Kobelev
ISI. A. Soynov
I. A. Soynov
Introduction. Transcatheter pulmonary valve implantation is one of the most relevant issues in endovascular surgery for congenital heart defects. However, at present, there is no “ideal” valve for transcatheter implantation. Balloon-expandable pulmonary valves for transcatheter implantation have a rigid frame, which requires pre-stenting of the native right ventricular outflow tract or the valve-containing conduit to avoid perioperative complications. This tactic increases the procedure time, complicates the valve implantation technique, and raises the cost of the operation. Self-expanding valves, which are primarily aimed at addressing pulmonary regurgitation, present an alternative. Determining an adequate implantation zone for the valve is crucial for the successful treatment of a dilated native right ventricular outflow tract. This is why preoperative CT imaging protocol, with 3D reconstruction providing detailed anatomical structures at every level, plays a significant role.Aims. To assess the properties of the transcatheter self-expanding frame of the pulmonary artery valve and to perform its in vitro implantation in a 3D model of a patient with right ventricular outflow tract dysfunction.Material and Methods. We developed a model of a self-expanding nitinol frame for a transcatheter valve for implantation in the position of the pulmonary artery, based on the most commonly encountered anatomy of right ventricular outflow tract dysfunction. We conducted tests for radial forces of the frame and valve loading trials in the delivery system. Results. A 3D reconstruction of the right heart chambers with the inferior vena cava was performed, with detailed anatomical structure delineation at each level. A 3D model was printed on an SLA 3D printer, Formlabs Form 3B+, using Elastic 50A photopolymer (Formlabs Inc., USA). Under fluoroscopic guidance, a test implantation of the pulmonary artery valve frame was carried out.Conclusion. By optimizing the design of the supporting frame, we were able to improve the transcatheter valve frame model based on the analysis of the most common right ventricular outflow tract dysfunctions. 3D-printed constructs enable the safe testing of developing transcatheter valve models and help identify and timely address any existing deficiencies.

14 October 2025 in Russian Journal of Cardiology
Verified
Journal Article
Open access
PDF file
ABA. G. Badoyan
A. G. Badoyan
ABA. A. Baranov
A. A. Baranov
MMM. A. Makhmudov
M. A. Makhmudov
OKO. V. Krestyaninov
O. V. Krestyaninov
VBV. P. Borodin
V. P. Borodin
ADAnna Dokuchaeva
Anna Dokuchaeva
Endovascular embolization using coils is a widely used method for treating various vascular pathologies. There are many types of coils, differing in design, material and technical characteristics, which allows choosing the best options depending on the clinical setting. The article discusses the main types of endovascular coils and their technical features. The final part presents cases of successful use of endovascular embolization coils and stopping bleeding, demonstrating its high potential and important role in modern interventional therapy.

28 July 2025 in Russian Journal of Cardiology and Cardiovascular Surgery
Verified
Journal Article
Closed access
KRK.A. Rzayeva
K.A. Rzayeva
SMS.N. Manukyan
S.N. Manukyan
SVS.V. Vladimirov
S.V. Vladimirov
VBV.P. Borodin
V.P. Borodin
IZIrina Y. Zhuravleva
Irina Y. Zhuravleva
ISI.A. Soynov
I.A. Soynov
Objective. To evaluate early postoperative and mid-term results of transcatheter implantation of pulmonary artery valve. Material and methods. Mini-pigs ICiG were used in this preclinical study. The object of the study was transcatheter pulmonary valve bioprosthesis. We used 2 healthy white pigs (2 females) aged 12 and 14 months, respectively. Weight of pigs was 56 and 60 kg, respectively. Pulmonary valve implantation was performed through left-sided anterior mini-thoracotomy. Results. Both implantations through mini-thoracotomy were successful. Mean pressure gradient was 14 and 10 mm Hg, respectively. After 3 months, transvalvular pressure gradient was 17.6 and 14.7 mm Hg, respectively. There was no central regurgitation. We observed mild periprosthetic regurgitation in the second animal without any clinical symptoms. Conclusion. Design of new transcatheter self-opening pulmonary valve is safe and effective.