Al-Hassan Diab

Al-Hassan Diab

Auto-generated profile, based on publicly available information

Al-Hassan Diab

Department of Oral Medicine, Periodontology and Diagnosis, Faculty of Dentistry, British University in Egypt, Cairo, Egypt

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 December 2024 in Future Science OA
Verified
Journal Article
Open access
DGDalia Ghalwash
Dalia Ghalwash
AAAhmed Ammar
Ahmed Ammar
AAAsmaa Abou-Bakr
Asmaa Abou-Bakr
ADAl-Hassan Diab
Al-Hassan Diab
AEAyman El-Gawish
Ayman El-Gawish
The present study evaluated the sensitivity and specificity of important proteomic salivary biomarkers; IL-6, IL-8, and sCD44 in the early detection of oral cancer, and any possible associations with risk factors of oral cancer in an Egyptian population. The present investigation was conducted on 100 individuals; 25 healthy controls, 25 patients having oral potentially malignant disorders (OPMDs) with dysplasia; 25 patients having OPMDs without dysplasia, and 25 oral cancer patients. Demographic data modified gingival index, oral hygiene level, and salivary levels of the biomarkers were assessed. Salivary levels of IL-6, IL-8, and sCD44 progressively increased with increased disease severity. Salivary IL-8 and IL-6 levels possess a discriminating potential from normal tissue through different degrees of dysplasia to oral cancer, sCD44 levels had a discriminating power between normal and dysplastic tissues with high sensitivity and specificity. A positive correlation was found between the three biomarkers and the grade of oral squamous cell carcinoma (OSCC) and with different risk factors. This is the first study that evaluated multiple salivary proteomic biomarkers in the Egyptian population, and the results validate the ability of IL-6, IL-8, and sCD44 to be used as sensitive diagnostic and prognostic biomarkers for screening and early detection of oral cancer.

18 December 2024 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
HSHatem S. Sadek
Hatem S. Sadek
NANoha Mohamed Abd El-kader Anany
Noha Mohamed Abd El-kader Anany
MEMohamed Ibrahim El-Anwar
Mohamed Ibrahim El-Anwar
AAAbdulaziz Alhotan
Abdulaziz Alhotan
ADAl-Hassan Diab
Al-Hassan Diab
CBChristoph P Bourauel
Christoph P Bourauel
To evaluate the biomechanical performance of various designs of cantilevered three-unit implant-supported prostheses, using two distinct prosthetic materials and under different loading conditions. Three mandibular models were created with varying implant positions to support a 3-unit prosthesis using two materials (Zirconia and PEKK), resulting in three different designs: distal cantilever (M1), fixed-fixed (M2), and mesial cantilever (M3). The geometric model was created by segmenting a CBCT scan of an edentulous mandible using Mimics software, followed by refinement in 3-Matic to generate a trabecular bone core encased by a 2 mm-thick cortical shell and a 1 mm-thick mucosal layer. Implant CAD files were integrated, and the models were processed in SolidWorks to finalize solid geometries. These were then imported into ANSYS for mesh generation and finite element analysis, with materials assumed to be isotropic and elastic. Models underwent 3 different static loading protocols (Vertical 100 N, 30° Oblique 50 N, 45° Oblique 50 N). Von Mises stress and total deformation were calculated. Model 2 demonstrated the best performance. Under vertical loading, PEKK prostheses showed lower stress than zirconia in the prosthetic body (10-45 %) and the cortical bone (3-40 %), but higher stresses in the implant (4-10 %). Compared to vertical loading, oblique loading generated higher stress but remained within a safe range without compromising function. The fixed-fixed design showed optimal biomechanical performance. The mesial cantilever was more favorable than the distal for stress distribution. Zirconia provided superior stress dissipation, while PEKK showed reduced stress in the prosthetic body but increased stress I the implant and bone. The study provides prosthodontists with evidence recommending design and materials for 3-unit implant-supported prostheses. Zirconia is ideal for cantilevered designs, resisting high bending forces and minimizing implant stress, while PEKK is more suitable for fixed-fixed designs with lower stress levels.

10 September 2025 in International Dental Journal
Verified
Journal Article
Open access
HSHatem S. Sadek
Hatem S. Sadek
NANoha M. Anany
Noha M. Anany
MEMohamed Ibrahim El-Anwar
Mohamed Ibrahim El-Anwar
AAAbdulaziz Alhotan
Abdulaziz Alhotan
ADAl-Hassan Diab
Al-Hassan Diab
Tarek M. ElshazlyTarek M. Elshazly
Tarek M. Elshazly
To assess the biomechanical behaviour of implant-tooth-supported (hybrid) prostheses, compared with an implant-implant-supported prosthesis, utilising two different prosthetic materials, employing finite element analysis (FEA). Three digital models, derived from a CBCT-scanned edentulous mandible, were designed: two hybrid configurations (M1: distal implant-first premolar; M2: mesial implant-first molar) and an implant-implant-supported prosthesis (M3). A biomechanical modelling workflow was carried out (Mimics for segmentation, 3-Matic for bone/mucosal layer refinement, Exocad DentalCAD and SolidWorks for implants, abutment and prosthesis integration, and ANSYS for meshing and FEA). Assuming isotropic/elastic material properties, zirconia and polyetherketoneketone (PEKK) were selected as prosthetic materials. Models were subjected to a static vertical load (100 N). von Mises stress and total deformation were analysed to evaluate structural responses. M3 demonstrated the most favourable biomechanical profile, exhibiting the lowest von Mises stress magnitudes alongside the highest overall deformation. In hybrid models (M1, M2), stress maxima were localised at the pontic-tooth connector regions and, in M1-PEKK, reached 261 MPa in the screw. Cortical bone and prepared teeth exhibited higher stress in distally anchored hybrid systems (M1) compared to mesially supported designs (M2), regardless of the prosthetic material. Comparative analysis revealed that zirconia-based prostheses generated higher stress concentrations in bone (≤35 MPa) compared to PEKK, whereas the PEKK prosthesis itself exhibited greater structural deformation (70 µm in M1-PEKK). Hybrid implant-tooth-supported prostheses can act as a reliable alternative to implant-implant ones and eliminate cantilever extensions; however, their use should be reserved for carefully selected cases to avoid biomechanical incompatibilities.

11 February 2025 in International Dental Journal
Verified
Journal Article
Open access
HSHatem S. Sadek
Hatem S. Sadek
NANoha Mohamed Abd El-kader Anany
Noha Mohamed Abd El-kader Anany
ADAl-Hassan Diab
Al-Hassan Diab
MEMohamed Ibrahim El-Anwar
Mohamed Ibrahim El-Anwar
AAAbdulaziz Alhotan
Abdulaziz Alhotan
Tarek M. ElshazlyTarek M. Elshazly
Tarek M. Elshazly
To assess the biomechanical performance of cantilevered 2-unit implant-supported prostheses with zirconia and polyetherketoneketone (PEKK) under 3 loading conditions. A cone beam computer tomography (CBCT) scan of an edentulous mandible was segmented using Mimics software and refined in 3-Matic software to create trabecular and cortical bone structures. Implant CAD files were integrated using SolidWorks software, generating 4 models with varying implant positions: M1 (first premolar implant supporting a second premolar), M2 (second premolar implant supporting a first premolar), M3 (second premolar implant supporting a first molar), and M4 (first molar implant supporting a second premolar). Prostheses were constructed from zirconia or PEKK. Finite element analysis (FEA) in ANSYS software simulated static loading: vertical (100 N) and oblique (30° and 45°, 50 N). von Mises stress and total deformation were analyzed. Vertical loading showed the highest von Mises stress at cantilever connectors, with M3 displaying the highest cortical bone stress (117 MPa). Zirconia models had slightly higher prosthetic stress, while PEKK models exhibited greater implant and cortical bone stress. Oblique loading caused higher stress in implants and prostheses but remained below yield limits. Maximum deformation was under 25 micrometers for the implant and bone, and 65 micrometers for the prosthesis. Single implants can support 2-unit cantilevered prostheses when additional implants are unfeasible. The location of the cantilever has minimal impact compared to its size, as a larger cantilevered part increases stress. Zirconia better resists bending forces and reduces implant stress compared to PEKK. This study guides prosthodontists in designing 2-unit implant-supported prostheses, emphasizing that multiple implants optimize stress distribution, and that zirconia is preferable for cantilevered designs.

18 January 2025 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
Mostafa AldesokiMostafa Aldesoki
Mostafa Aldesoki
LKLudger Keilig
Ludger Keilig
AAAbdulaziz Alhotan
Abdulaziz Alhotan
ADAl-Hassan Diab
Al-Hassan Diab
Tarek M. ElshazlyTarek M. Elshazly
Tarek M. Elshazly
CBChristoph P Bourauel
Christoph P Bourauel
To create a validated 3D finite element model and employ it to examine the biomechanical behaviour of multirooted root analogue implants (RAIs). A validated finite element model comprising either an RAI or a threaded implant (TI) and an idealised bone block was developed based on a previously conducted in vitro study. All the experimental boundary conditions and material properties were reproduced. Force/displacement curves were plotted to ensure complete alignment with the in vitro findings. Following the validation of the FE model, the material properties were adjusted to align with those reported in the literature. Two contact scenarios were then examined: immediate placement with touching contact and osseointegration with glued contact. The bone block was constrained in all directions, and a 300 N point load was applied along the long axis of the implant, and with an angulation of 30°. The resulting values for equivalent stress, maximum principal stress, microstrain, and displacement were evaluated. The numerical model demonstrated a high degree of agreement with the experimental results, particularly regarding displacement in the loading direction (Z). The findings of the applied FEA indicated that RAIs generally outperformed TIs. The RAI exhibited lower equivalent stress, with values of 3.3 MPa for axial loading and 13.1 MPa for oblique loading, compared to 5.4 MPa and 29.5 MPa for the TI, respectively. Furthermore, microstrain was observed to be lower in the RAI, with a value of 4,000 με compared to 13,000 με in the TI under oblique loading. Additionally, the RAI exhibited superior primary and secondary stability, with lower micromotion values compared to the TI. The root analogue implant showed superior biomechanical performance, with more uniform stress distribution and greater stability compared to the conventional threaded implant, positioning it as a promising alternative.

1 April 2023 in Egyptian Dental Journal
Verified
Journal Article
Open access
PDF file
SESarah Elkot
Sarah Elkot
Ola ElazazyOla Elazazy
Ola Elazazy
ADAl-Hassan Diab
Al-Hassan Diab
Background: Peri-implant infections occur in response to pathogenic bacterial flora in addition to release of inflammatory markers similarly to periodontal infection, but faster and more intensely. As the smoking is a critical modifying factor for periodontal disease intensity ,it can also be considered as a risk factor of periimplantitis. Subjects and methods: Fourteen participants with endo-osseous root form implant; seven of them are non smokers (group 1) and the other seven are smokers (group 2).Clinical parameters as plaque index (PI), gingival index (GI) and probing pocket depth (PPD) are recorded for each participant and also periimplant crevicular fluid (PICF) samples are collected from all participants to biochemically investigate levels of vascular endothelial growth factor (VEGF). Results: Clinical parameters as plaque index (PI), gingival index (GI) and probing pocket depth (PPD) were higher in smoker group compared to non smoker group .however, The VEGF levels in PICF were higher in the non smoker group compared to the smoker group. Conclusion: VEGF is not a highly sensitive pathogenesis maker and can not be used alone to predict periimplantitis.