Peter Ressel

Peter Ressel

Auto-generated profile, based on publicly available information

Peter Ressel

Ferdinand-Braun-Institut, Leibniz-Institut für Höchstfrequenztechnik (FBH) (Germany)

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 March 2020 in IEEE Photonics Technology Letters
Verified
Journal Article
Closed access
MWMartin Wilkens
Martin Wilkens
GEGotz Erbert
Gotz Erbert
HWHans Wenzel
Hans Wenzel
AMAndre Maabdorf
Andre Maabdorf
JFJorg Fricke
Jorg Fricke
PCPaul Crump
Paul Crump
In this letter we present new results on high power 970 nm ridge waveguide lasers based on an extreme double asymmetric epitaxial design. Due to an improved lateral-longitudinal design an M2-value below 1.1 and efficiency over 60% could be maintained at power levels slightly above 2 W. The lasers consist of a narrow mode-filter section at the back facet, a relatively broad section at the front facet for high power capability, and a tapered section in between with a very small taper-angle. We achieved the highest reported conversion efficiency for 1 W single lateral mode power to date of 67%, as well as the highest lateral (linear) brightness of 7.5 W/mm·mrad with 55% efficiency at 2.5 W. Results of first life time tests are presented which show the potential for commercial use.

23 May 2022 in IEEE Photonics Journal
Verified
Journal Article
Open access
JBJos Boschker
Jos Boschker
USUwe Spengler
Uwe Spengler
PRPeter Ressel
Peter Ressel
Martin SchmidbauerMartin Schmidbauer
Martin Schmidbauer
AMAnna Mogilatenko
Anna Mogilatenko
AKAndrea Knigge
Andrea Knigge
Catastrophic optical mirror damage (COMD) is one of the main failure mechanisms limiting the reliability of GaAs based laser diodes. Here, we compare the facet stability of ZnSe-passivated ridge-waveguide lasers (RWLs) that are cleaved in air and subsequently cleaned using atomic hydrogen with RWLs that are cleaved in ultra-high vacuum. RWLs cleaved in ultra-high vacuum show a superior performance and reach power densities up to 58 MW/cm 2 under extended continuous wave operation at 1064 nm. This is attributed to the reduction of defects at the interface between ZnSe and the cleaved facet as evidenced by transmission electron microscopy and X-ray diffraction.

9 July 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
TNThanh-Phuong Nguyen
Thanh-Phuong Nguyen
HWHans Wenzel
Hans Wenzel
OBOlaf Brox
Olaf Brox
FBFrank Bugge
Frank Bugge
PRPeter Ressel
Peter Ressel
GTGünther Tränkle
Günther Tränkle
The influence of the front facet reflectivity on the spectral linewidth of high power DFB (distributed feedback) diode lasers emitting at 780 nm has been investigated theoretically and experimentally. Characterization of lasers at various front facet reflections showed substantial reduction of the linewidth. This behavior is in reasonable agreement with simulation results. A minimum linewidth of 8 kHz was achieved at an output power of 85 mW with the laser featuring a front facet reflectivity of 30%. The device with a front facet reflectivity of 5% reached the same linewidth value at an output power of 290 mW.

10 December 2019 in IEEE Photonics Technology Letters
Verified
Journal Article
Closed access
CZChristof Zink
Christof Zink
AMAndre Maabdorf
Andre Maabdorf
JFJorg Fricke
Jorg Fricke
PRPeter Ressel
Peter Ressel
BSBernd Sumpf
Bernd Sumpf
GTGunther Trankle
Gunther Trankle

26 July 2021 in IEEE Photonics Technology Letters
Verified
Journal Article
Closed access
KHKarl Hausler
Karl Hausler
RSRalf Staske
Ralf Staske
AMAndre Maabdorf
Andre Maabdorf
PRPeter Ressel
Peter Ressel
CSChristoph Stolmacker
Christoph Stolmacker
PCPaul Crump
Paul Crump
Laser diode benches (LDBs) with lasing wavelength of 808 nm were developed, manufactured and endurance-tested for utilization as pump lasers for the Nd:YAG oscillator in the climate satellite MERLIN. The LDBs combine customized TE-polarized GaAs-based 5-mm minibars with fast axis collimation lenses to produce a reliable, space qualified component at optical power of 63 W per minibar. Accelerated life tests of 20 LDBs are presented. Except for a small increase in threshold current, no wear out in operating current or sudden failures were observed, and reliable operation over the full mission time of >4 gigashots was confirmed. The electro-optical characteristics remain in the specified ranges after exposure to the total operational load of the mission.

17 March 2023
Verified
Conference Paper
Closed access
PDF file
GBGunnar Blume
Gunnar Blume
OMOliver Matalla
Oliver Matalla
HWHans Wenzel
Hans Wenzel
AMAndre Maassdorf
Andre Maassdorf
DFDavid Feise
David Feise
AMA. Maaßdorf
A. Maaßdorf
For several non-destructive spectroscopy methods based on quantum mechanical effects (e.g. MID-IR quantum-OCT) the size of currently used solid state lasers prevents effective miniaturization. Red-emitting diode lasers with single longitudinal and single lateral mode emission are therefore required for successful out-of-the lab usage. To address this challenge, the FBH developed specialized tapered lasers (TPL) emitting near 660 nm with an integrated tenth order distributed Bragg reflector (DBR) surface grating, requiring only a single epitaxy step. The facets were passivated and coated to obtain reflectivities of 5% for the front and 30% for the rear facet. The DBR-TPL chips were mounted p-side down on CVD-diamonds with structured contacts to allow separate contacting of the ridge waveguide (RW) and tapered (TP) sections. The DBR-TPLs feature a nearly diffraction limited output beam with a spectral width below 0.5 pm, corresponding to a coherence length of almost 1 m. An optical output power of more than 1 W could be demonstrated at currents of 50 mA and 2.5 A for the RW and TP sections, respectively. The beam quality at 1 W was M21/e2 = 1.1 (M24σ = 2.1). The DBR-TPLs are a first important component in the concept for a miniaturized portable quantum-OCT scanner. Here, the sample will be illuminated with MID-IR photons while the entangled NIR photons will be measured with a cost-effective, Si-based spectrometer.