Patrick Hayes

Patrick Hayes

Auto-generated profile, based on publicly available information

Patrick Hayes

Inorganic Functional Materials, Department of Materials Science, Kiel University 1 , Kiel 24143, Germany

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 July 2019 in Materials
Verified
Journal Article
Open access
PDF file
Cheng TuCheng Tu
Cheng Tu
Zhaoqiang ChuZhaoqiang Chu
Zhaoqiang Chu
BSBenjamin Spetzler
Benjamin Spetzler
PHPatrick Hayes
Patrick Hayes
Cunzheng DongCunzheng Dong
Cunzheng Dong
Nian-Xiang SunNian-Xiang Sun
Nian-Xiang Sun
The strong strain-mediated magnetoelectric (ME) coupling found in thin-film ME heterostructures has attracted an ever-increasing interest and enables realization of a great number of integrated multiferroic devices, such as magnetometers, mechanical antennas, RF tunable inductors and filters. This paper first reviews the thin-film characterization techniques for both piezoelectric and magnetostrictive thin films, which are crucial in determining the strength of the ME coupling. After that, the most recent progress on various integrated multiferroic devices based on thin-film ME heterostructures are presented. In particular, rapid development of thin-film ME magnetometers has been seen over the past few years. These ultra-sensitive magnetometers exhibit extremely low limit of detection (sub-pT/Hz1/2) for low-frequency AC magnetic fields, making them potential candidates for applications of medical diagnostics. Other devices reviewed in this paper include acoustically actuated nanomechanical ME antennas with miniaturized size by 1–2 orders compared to the conventional antenna; integrated RF tunable inductors with a wide operation frequency range; integrated RF tunable bandpass filter with dual H- and E-field tunability. All these integrated multiferroic devices are compact, lightweight, power-efficient, and potentially integrable with current complementary metal oxide semiconductor (CMOS) technology, showing great promise for applications in future biomedical, wireless communication, and reconfigurable electronic systems.

28 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
EEEric Elzenheimer
Eric Elzenheimer
CBChristin Bald
Christin Bald
EEErik Engelhardt
Erik Engelhardt
JHJohannes Hoffmann
Johannes Hoffmann
PHPatrick Hayes
Patrick Hayes
Gerhard SchmidtGerhard Schmidt
Gerhard Schmidt
Dedicated research is currently being conducted on novel thin film magnetoelectric (ME) sensor concepts for medical applications. These concepts enable a contactless magnetic signal acquisition in the presence of large interference fields such as the magnetic field of the Earth and are operational at room temperature. As more and more different ME sensor concepts are accessible to medical applications, the need for comparative quality metrics significantly arises. For a medical application, both the specification of the sensor itself and the specification of the readout scheme must be considered. Therefore, from a medical user’s perspective, a system consideration is better suited to specific quantitative measures that consider the sensor readout scheme as well. The corresponding sensor system evaluation should be performed in reproducible measurement conditions (e.g., magnetically, electrically and acoustically shielded environment). Within this contribution, an ME sensor system evaluation scheme will be described and discussed. The quantitative measures will be determined exemplarily for two ME sensors: a resonant ME sensor and an electrically modulated ME sensor. In addition, an application-related signal evaluation scheme will be introduced and exemplified for cardiovascular application. The utilized prototype signal is based on a magnetocardiogram (MCG), which was recorded with a superconducting quantum-interference device. As a potential figure of merit for a quantitative signal assessment, an application specific capacity (ASC) is introduced. In conclusion, this contribution highlights metrics for the quantitative characterization of ME sensor systems and their resulting output signals in biomagnetism. Finally, different ASC values and signal-to-noise ratios (SNRs) could be clearly presented for the resonant ME sensor (SNR: −90 dB, ASC: 9.8×10−7 dB Hz) and also the electrically modulated ME sensor (SNR: −11 dB, ASC: 23 dB Hz), showing that the electrically modulated ME sensor is better suited for a possible MCG application under ideal conditions. The presented approach is transferable to other magnetic sensors and applications.

1 August 2018 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
PDF file
PHPatrick Hayes
Patrick Hayes
VSViktor Schell
Viktor Schell
SSSebastian Salzer
Sebastian Salzer
DBDmitrii Burdin
Dmitrii Burdin
EYErdem Yarar
Erdem Yarar
RKReinhard H Knoechel
Reinhard H Knoechel
Measurements of the converse magnetoelectric effect, observed for mesoscopic cantilever type magnetoelectric composites, are presented. The silicon based samples employ 2 µ m of amorphous (Fe 90 Co 10 ) 78 Si 12 B 10 film as soft magnetic, magnetostrictive phase. The piezoelectric phase consists of 2 µ m sputter deposited, highly textured aluminum nitride (AlN) in a plate capacitor arrangement. Exciting the piezoelectric phase at various frequencies leads to sharp peaks of induced voltage in a surrounding, mechanically decoupled pickup coil, corresponding to several mechanical resonances of the beam. The peak amplitude modulation can be exploited to detect DC magnetic fields. This entirely passive readout strategy is advantageous over other methods of sensitivity enhancement, typically requiring an active source of magnetic fields, thus prohibiting the construction of sensor arrays. Field dependent mechanical quality factors of up to 3800 near magnetic saturation are featured by a strong field dependence of induced voltage, reaching to 2290 V T −1 in the 20 µ T field regime. Vibrational measurements reveal a combination of the 15th flexural with a high order torsional mode as primarily active, at a resonance frequency of 520.7 kHz. This finding is supported by simple analytical estimations and literature. In unbiased operation, a linear resolution of 1.2 nT towards small 200 mHz fields is shown.

22 April 2024 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
LTLars Thormählen
Lars Thormählen
PHP. Hayes
P. Hayes
EEEric Elzenheimer
Eric Elzenheimer
EGElizaveta Golubeva
Elizaveta Golubeva
Gerhard SchmidtGerhard Schmidt
Gerhard Schmidt
Eckhard QuandtEckhard Quandt
Eckhard Quandt
In the development of any type of magnetic field sensor based on magnetic films, special consideration must be given to the magnetic layer component. The presented work investigates the use of scalable flux closing magnetostrictive multilayers for inverse magnetoelectric sensors. In such a type of magnetic field sensor, highly sensitive AC and DC field detection relies on strong excitation of the incorporated magnetic layers by piezoelectrically driven cantilever oscillation at mechanical resonances. The provoked periodic flux change is influenced by the magnetic field to be measured and is picked up by a coil, which generates the measured output. The multilayered inverse magnetoelectric sensor is investigated with regard to linearity, noise behavior, and detection limit of DC and AC signals. A significant advancement for inverse magnetoelectric thin film sensors is demonstrated in this study. Using exchange bias stabilized magnetic multilayers with flux closure structures, detection limits are improved by an order of magnitude to less than 8 pT/Hz1/2 at 10 Hz and 18 pT/Hz1/2 at DC.

9 July 2018 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
YFYuri Fetisov
Yuri Fetisov
DBDmitri A. Burdin
Dmitri A. Burdin
NENikolai A. Ekonomov
Nikolai A. Ekonomov
LFLeonid Y. Fetisov
Leonid Y. Fetisov
ABAlexey A. Berzin
Alexey A. Berzin
Eckhard QuandtEckhard Quandt
Eckhard Quandt
Bistable characteristics of a nonlinear multiferroic composite resonator containing ferromagnetic and piezoelectric layers are investigated. The resonator was a borosilicate glass substrate of 25 mm × 2 mm dimensions and 150 μm thickness with a 2 μm thick amorphous ferromagnetic FeCoSiB layer and a 2 μm thick piezoelectric AlN layer deposited on its sides by magnetron sputtering. The resonator was excited by ac voltage at a frequency of 156 kHz, matching its longitudinal acoustic resonance frequency. The bistability loops were observed with increasing and decreasing frequency at constant excitation voltage and with increasing and decreasing voltage at constant frequency. With increasing excitation voltage, the resonator frequency first decreases by ∼0.7 kHz and then increases again to the initial value. A bistability model is suggested that uses Lorentzian shape resonance line and measured dependences of the resonance frequency and transmission coefficient on the output signal, which quantitatively describes experimental data. It is shown that bistability in a multiferroic resonator arises due to the nonlinearity of the ferromagnetic layer.

1 March 2021 in Technical Physics Letters
Verified
Journal Article
Closed access
PDF file
DBD. A. Burdin
D. A. Burdin
PHP. Hayes
P. Hayes
NEN. A. Ekonomov
N. A. Ekonomov
DCD. V. Chashin
D. V. Chashin
YFYuri Fetisov
Yuri Fetisov
The high-frequency magnetoelectric effect is found in a planar structure consisting of a ferromagnetic FeCoSiB layer and a piezoelectric AlN layer deposited by magnetron sputtering on a borosilicate glass substrate. The structure has been excited by a magnetic field at the frequency of the thickness acoustic vibration mode (32.4 MHz), and the electric voltage generated by the piezoelectric layer was recorded. The magnetoelectric conversion factor at the frequency of the second bulk mode is αE ≈ 6 V/A at a dc bias magnetic field of 120 A/m corresponding to the maximum piezomagnetic constant of the ferromagnetic layer.