Tim M. Bruns

Tim M. Bruns

Auto-generated profile, based on publicly available information

Tim M. Bruns

Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2013 in Journal of Rehabilitation Research and Development
Verified
Journal Article
Closed access
JCJennifer L. Collinger
Jennifer L. Collinger
MBMichael L. Boninger
Michael L. Boninger
TBTim M. Bruns
Tim M. Bruns
KCKenneth Curley
Kenneth Curley
WWWei Wang
Wei Wang
DWDouglas J. Weber
Douglas J. Weber
Spinal cord injury (SCI) often affects a person's ability to perform critical activities of daily living and can negatively affect his or her quality of life. Assistive technology aims to bridge this gap in order to augment function and increase independence. It is critical to involve consumers in the design and evaluation process as new technologies such as brain-computer interfaces (BCIs) are developed. In a survey study of 57 veterans with SCI participating in the 2010 National Veterans Wheelchair Games, we found that restoration of bladder and bowel control, walking, and arm and hand function (tetraplegia only) were all high priorities for improving quality of life. Many of the participants had not used or heard of some currently available technologies designed to improve function or the ability to interact with their environment. The majority of participants in this study were interested in using a BCI, particularly for controlling functional electrical stimulation to restore lost function. Independent operation was considered to be the most important design criteria. Interestingly, many participants reported that they would consider surgery to implant a BCI even though noninvasiveness was a high-priority design requirement. This survey demonstrates the interest of individuals with SCI in receiving and contributing to the design of BCIs.

1 July 2013 in The Journal of Spinal Cord Medicine
Verified
Journal Article
Closed access
JCJennifer L. Collinger
Jennifer L. Collinger
SFStephen Foldes
Stephen Foldes
TBTim M. Bruns
Tim M. Bruns
BWBrian Wodlinger
Brian Wodlinger
RGRobert Gaunt
Robert Gaunt
DWDouglas J. Weber
Douglas J. Weber
Spinal cord injury (SCI) results in a loss of function and sensation below the level of the lesion. Neuroprosthetic technology has been developed to help restore motor and autonomic functions as well as to provide sensory feedback. This paper provides an overview of neuroprosthetic technology that aims to address the priorities for functional restoration as defined by individuals with SCI. We describe neuroprostheses that are in various stages of preclinical development, clinical testing, and commercialization including functional electrical stimulators, epidural and intraspinal microstimulation, bladder neuroprosthesis, and cortical stimulation for restoring sensation. We also discuss neural recording technologies that may provide command or feedback signals for neuroprosthetic devices. Neuroprostheses have begun to address the priorities of individuals with SCI, although there remains room for improvement. In addition to continued technological improvements, closing the loop between the technology and the user may help provide intuitive device control with high levels of performance.

23 September 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
AJAhmad A. Jiman
Ahmad A. Jiman
DRDavid C. Ratze
David C. Ratze
EWElissa J. Welle
Elissa J. Welle
PPParas R. Patel
Paras R. Patel
JRJulianna M. Richie
Julianna M. Richie
TBTim M. Bruns
Tim M. Bruns
Autonomic nerves convey essential neural signals that regulate vital body functions. Recording clearly distinctive physiological neural signals from autonomic nerves will help develop new treatments for restoring regulatory functions. However, this is very challenging due to the small nature of autonomic nerves and the low-amplitude signals from their small axons. We developed a multi-channel, high-density, intraneural carbon fiber microelectrode array (CFMA) with ultra-small electrodes (8–9 µm in diameter, 150–250 µm in length) for recording physiological action potentials from small autonomic nerves. In this study, we inserted CFMA with up to 16 recording carbon fibers in the cervical vagus nerve of 22 isoflurane-anesthetized rats. We recorded action potentials with peak-to-peak amplitudes of 15.1–91.7 µV and signal-to-noise ratios of 2.0–8.3 on multiple carbon fibers per experiment, determined conduction velocities of some vagal signals in the afferent (0.7–4.4 m/s) and efferent (0.7–8.8 m/s) directions, and monitored firing rate changes in breathing and blood glucose modulated conditions. Overall, these experiments demonstrated that CFMA is a novel interface for in-vivo intraneural action potential recordings. This work is considerable progress towards the comprehensive understanding of physiological neural signaling in vital regulatory functions controlled by autonomic nerves.

15 March 2013 in Journal of Neural Engineering
Verified
Journal Article
Closed access
TBTim M Bruns
Tim M Bruns
JWJoost B Wagenaar
Joost B Wagenaar
MBMatthew J Bauman
Matthew J Bauman
RGRobert A Gaunt
Robert A Gaunt
DWDouglas J Weber
Douglas J Weber
Functional electrical stimulation (FES) approaches often utilize an open-loop controller to drive state transitions. The addition of sensory feedback may allow for closed-loop control that can respond effectively to perturbations and muscle fatigue. We evaluated the use of natural sensory nerve signals obtained with penetrating microelectrode arrays in lumbar dorsal root ganglia (DRG) as real-time feedback for closed-loop control of FES-generated hind limb stepping in anesthetized cats. Leg position feedback was obtained in near real-time at 50 ms intervals by decoding the firing rates of more than 120 DRG neurons recorded simultaneously. Over 5 m of effective linear distance was traversed during closed-loop stepping trials in each of two cats. The controller compensated effectively for perturbations in the stepping path when DRG sensory feedback was provided. The presence of stimulation artifacts and the quality of DRG unit sorting did not significantly affect the accuracy of leg position feedback obtained from the linear decoding model as long as at least 20 DRG units were included in the model. This work demonstrates the feasibility and utility of closed-loop FES control based on natural neural sensors. Further work is needed to improve the controller and electrode technologies and to evaluate long-term viability.

30 August 2011 in Journal of Neural Engineering
Verified
Journal Article
Closed access
TBTim M Bruns
Tim M Bruns
RGRobert A Gaunt
Robert A Gaunt
DWDouglas J Weber
Douglas J Weber
The development of bladder and bowel neuroprostheses may benefit from the use of sensory feedback. We evaluated the use of high-density penetrating microelectrode arrays in sacral dorsal root ganglia (DRG) for recording bladder and perineal afferent activity. Arrays were inserted in S1 and S2 DRG in three anesthetized cats. Neural signals were recorded while the bladder volume was modulated and mechanical stimuli were applied to the perineal region. In two experiments, 48 units were observed that tracked bladder pressure with their firing rates (79% from S2). At least 50 additional units in each of the three experiments (274 total; 60% from S2) had a significant change in their firing rates during one or more perineal stimulation trials. This study shows the feasibility of obtaining bladder-state information and other feedback signals from the pelvic region with a sacral DRG electrode interface located in a single level. This natural source of feedback would be valuable for providing closed-loop control of bladder or other pelvic neuroprostheses.