27 December 2018 in IEEE Transactions on Biomedical Engineering
Frequency dependence of respiratory mechanics is a well-established behavior of the respiratory system and is known to be an indicator of severity of obstructive disease, attributed to both tissue viscoelasticity and heterogeneity of airflow in the lung. Despite the fact that respiratory parameters are known to vary in time, often amplified in disease, all analysis methods assume stationarity or short-time stationarity in the parameters used to describe the respiratory system, and the effects of this assumption have not yet been examined in any detail. Here, using a generalized approach, we developed a theory for time-varying respiratory mechanics in time-frequency domain for analysis of linear time-varying systems, then, we analyzed the same respiratory system model with time-varying parameters in the time domain. Both time-frequency domain and time-domain derivations revealed a striking correlation between time-varying behavior of the respiratory system and frequency dependence of resistance. Remarkably, this phenomenon arose from the amplitude of time variations of the elastance. This links two mechanisms that are known to increase in obstructive disease: apparent low frequency increases in resistance and the time variations of reactance.
14 June 2021 in IEEE Sensors Journal
Measuring fluid flow velocity using ultrasonic based sensors has been established for some time, however implementation of this technology in respiratory systems is relatively recent. This paper presents the design of a respiratory flow sensor made possible by the air-coupling ultrasound principle. A prototype has been developed as a proof-of-concept. To enhance the signal to noise ratio (SNR), the modulated ultrasound arrival time is translated to a digital word using Time-to-Digital Conversion (TDC). Hence, the respiration is digitally captured in real-time to offer a synchronous respiratory monitoring. The near-zero deviation is further alleviated by Least Mean Square (LMS) technique accomplished off-line. Down to 0.03 L/s of resolution and over 95% of linearity is achieved. The bidirectional transmit/receive echo signals have been leveraged to provide a system level cancelation of the environmental conditions affecting measurement accuracy. The developed sensor was used on adult volunteers and tested experimentally using an ASL5000 lung simulator. The results validate the system functionality in the presence of real-world conditions.
20 July 2022 in IEEE Sensors Journal
An integrated lock-in amplifier (LIA) with automatic phase tuning and second-order harmonic frequency extraction is presented in this paper. The automatic phase alignment loop implemented in the proposed single-channel LIA can directly align the phases of an input signal with a reference signal. Furthermore, the proposed LIA system also includes an enhanced signal detection method in which the 2nd harmonics of the carrier frequency (ωref) is applied. As opposed to conventional LIA, this method reduces flicker noise and input offset effects that limit the signal-to-noise ratio (SNR). In terms of signal power detection, the proposed single-channel LIA architecture does not require phase synchronization between input and reference signals. The circuit is designed for a reference frequency of 100 Hz, suitable for biomedical applications. The LIA is Implemented using 0.18-μm CMOS technology with a single power supply voltage of 1.8 V. The system consumes 360 μW at an operating frequency of 100 Hz and presents a high input sensitivity dynamic range for a detection bandwidth of 50 Hz and a FOM of 116 dB.
30 September 2018 in IEEE Sensors Journal
Oscillometry is a useful measure of lung function and recently has been used to estimate temporal variation in physiological mechanical properties of the lung, but to date, analysis methods assume stationarity or short-time stationarity despite substantial temporal variation, particularly in disease. The effect of time-varying parameters on the accuracy of estimates of impedance has not been previously analyzed. In this paper we analytically, computationally, and with added experimental data from seven children with asthma, assess the time-frequency transfer function of the time-varying respiratory system. We then evaluate the accuracy in determining the time-varying parameters of respiratory impedance. We introduce, for the first time, the error arising from respiratory time variation, termed the time-varying error (TVE) and demonstrate how TVE unexpectedly increases with increasing breathing rate independent of breathing noise amplitude. For breathing rates less than 0.4 Hz, we found that common analysis methods could be moderately accurate with less than 5% error. Since tracking time-varying impedance shows strong potential for assessing the severity of respiratory disease, it is import to recognize that errors should be avoided, or compensation circuits and systems developed based on the TVE, particularly important in patients with high variation or breathing rate such as children and infants.
28 December 2021 in IEEE Transactions on Biomedical Engineering
Oscillometry or Forced Oscillation Technique, traditionally used in intermittent clinical measurements, has recently gained substantial attention from its application as a continuous monitoring tool for large and small airways. However, low frequency (< 8 Hz) continuous oscillometry faces high breathing noise, and hence requires high oscillation amplitudes to maintain an acceptable signal-to-noise ratio. Therefore, PAP machines that utilize low frequency oscillometry do so intermittently to distinguish airway patency several seconds after a breathing pause has occurred. We hypothesized that high frequency and low amplitude (HFLA) oscillometry may be as sensitive and applicable for monitoring upper airway patency to distinguish between central and obstructive apnea and hypopnea events, and for monitoring respiratory impedance. An inline oscillometry prototype device was developed and connected to commercial PAP machines to test whether oscillometry at 17, 43, and 79 Hz are as sensitive to airway patency as oscillometry at 4 Hz. Analysis of 11 patients with 171 apneas and hypopneas showed that all frequency oscillometry inputs were equally sensitive in distinguishing between central and obstructive apneas, while 17 Hz and 43 Hz oscillometry were most sensitive in distinguishing between central and obstructive hypopneas. Observations during normal breathing also showed the same periodicity and cross-correlation between impedance measurements from HFLA oscillometry compared to 4 Hz. Our findings provide an unobtrusive means of distinguishing airway patency during sleep and a means of continuous monitoring of respiratory function, with the potential for detection and prediction of developing respiratory diseases and significantly richer context for data analytics.
30 March 2023 in IEEE Transactions on Biomedical Engineering
Positive Airway Pressure (PAP) therapy is the most common and efficacious treatment for Obstructive Sleep Apnea (OSA). However, it suffers from poor patient adherence due to discomfort and may not fully alleviate all adverse consequences of OSA. Identifying abnormal respiratory events before they have occurred may allow for improved management of PAP levels, leading to improved adherence and better patient outcomes. Our previous work has resulted in the successful development of a Machine-Learning (ML) algorithm for the prediction of future apneic events using existing airflow and air pressure sensors available internally to PAP devices. Although researchers have studied the use of ML for the prediction of apneas, research to date has focused primarily on using external polysomnography sensors that add to patient discomfort and has not investigated the use of internal-to-PAP sensors such as air pressure and airflow to predict and prevent respiratory events. We hypothesized that by using our predictive software, OSA events could be proactively prevented while maintaining patients' sleep quality. An intervention protocol was developed and applied to all patients to prevent OSA events. Although the protocol's cool-down period limited the number of prevention attempts, analysis of 11 participants revealed that our system improved many sleep parameters, which included a statistically significant 31.6% reduction in Apnea-Hypopnea Index, while maintaining sleep quality. Most importantly, our findings indicate the feasibility of unobtrusive identification and unique prevention of each respiratory event as well as paving the path to future truly personalized PAP therapy by further training of ML models on individual patients.