Michael D. Paskett

Michael D. Paskett

Auto-generated profile, based on publicly available information

Michael D. Paskett

Center for Neural Interfaces, Department of Biomedical Engineering, University of Utah

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 October 2018 in Nature Medicine
Verified
Journal Article
Closed access
PDF file
JKJahyun Koo
Jahyun Koo
MMMatthew R. MacEwan
Matthew R. MacEwan
SKSeung-Kyun Kang
Seung-Kyun Kang
SWSang Min Won
Sang Min Won
MSManu Stephen
Manu Stephen
John A. RogersJohn A. Rogers
John A. Rogers

25 February 2021 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
MPMichael D. Paskett
Michael D. Paskett
MBMark R. Brinton
Mark R. Brinton
THTaylor C. Hansen
Taylor C. Hansen
JGJacob A. George
Jacob A. George
TDTyler S. Davis
Tyler S. Davis
GCGregory A. Clark
Gregory A. Clark
Background: Advanced prostheses can restore function and improve quality of life for individuals with amputations. Unfortunately, most commercial control strategies do not fully utilize the rich control information from residual nerves and musculature. Continuous decoders can provide more intuitive prosthesis control using multi-channel neural or electromyographic recordings. Three components influence continuous decoder performance: the data used to train the algorithm, the algorithm, and smoothing filters on the algorithm’s output. Individual groups often focus on a single decoder, so very few studies compare different decoders using otherwise similar experimental conditions. Methods: We completed a two-phase, head-to-head comparison of 12 continuous decoders using activities of daily living. In phase one, we compared two training types and a smoothing filter with three algorithms (modified Kalman filter, multi-layer perceptron, and convolutional neural network) in a clothespin relocation task. We compared training types that included only individual digit and wrist movements vs. combination movements (e.g., simultaneous grasp and wrist flexion). We also compared raw vs. nonlinearly smoothed algorithm outputs. In phase two, we compared the three algorithms in fragile egg, zipping, pouring, and folding tasks using the combination training and smoothing found beneficial in phase one. In both phases, we collected objective, performance-based (e.g., success rate), and subjective, user-focused (e.g., preference) measures. Results: Phase one showed that combination training improved prosthesis control accuracy and speed, and that the nonlinear smoothing improved accuracy but generally reduced speed. Phase one importantly showed simultaneous movements were used in the task, and that the modified Kalman filter and multi-layer perceptron predicted more simultaneous movements than the convolutional neural network. In phase two, user-focused metrics favored the convolutional neural network and modified Kalman filter, whereas performance-based metrics were generally similar among all algorithms. Conclusions: These results confirm that state-of-the-art algorithms, whether linear or nonlinear in nature, functionally benefit from training on more complex data and from output smoothing. These studies will be used to select a decoder for a long-term take-home trial with implanted neuromyoelectric devices. Overall, clinical considerations may favor the mKF as it is similar in performance, faster to train, and computationally less expensive than neural networks.

12 September 2019 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
MPMichael D. Paskett
Michael D. Paskett
NONathaniel R. Olsen
Nathaniel R. Olsen
JGJacob A. George
Jacob A. George
DKDavid T. Kluger
David T. Kluger
MBMark R. Brinton
Mark R. Brinton
GCGregory A. Clark
Gregory A. Clark
Bypass sockets allow researchers to perform tests of prosthetic systems from the prosthetic user’s perspective. We designed a modular upper-limb bypass socket with 3D-printed components that can be easily modified for use with a variety of terminal devices. Our bypass socket preserves access to forearm musculature and the hand, which are necessary for surface electromyography and to provide substituted sensory feedback. Our bypass socket allows a sufficient range of motion to complete tasks in the frontal working area, as measured on non-amputee participants. We examined the performance of non-amputee participants using the bypass socket on the original and modified Box and Block Tests. Participants moved 11.3 ± 2.7 and 11.7 ± 2.4 blocks in the original and modified Box and Block Tests (mean ± SD), respectively, within the range of reported scores using amputee participants. Range-of-motion for users wearing the bypass socket meets or exceeds most reported range-of-motion requirements for activities of daily living. The bypass socket was originally designed with a freely rotating wrist; we found that adding elastic resistance to user wrist rotation while wearing the bypass socket had no significant effect on motor decode performance. We have open-sourced the design files and an assembly manual for the bypass socket. We anticipate that the bypass socket will be a useful tool to evaluate and develop sensorized myoelectric prosthesis technology.

17 October 2019 in bioRxiv
Verified
Preprint
Open access
PDF file
NONathaniel R. Olsen
Nathaniel R. Olsen
JGJacob A. George
Jacob A. George
MBMark R. Brinton
Mark R. Brinton
MPMichael D. Paskett
Michael D. Paskett
DKDavid T. Kluger
David T. Kluger
GCGregory A. Clark
Gregory A. Clark
Many presently available prostheses lack a functional wrist. To fill this niche and to better understand the impact a wrist has in prosthetic functionality, we designed a low-cost, adaptable, 3D-printable prosthetic wrist that can be adapted to various prosthetic hands and sockets. The wrist utilizes inexpensive but powerful servo motors to provide simultaneous and proportional control of two degrees of freedom: pronation/supination and flexion/extension or radial/ulnar deviation. Participants used both our wrist and a commercially available wrist (DEKA “LUKE” Arm) to complete a modified version of the clothespin relocation task with and without the wrists enabled. Through use of the NASA Task Load Index we found that both wrists significantly reduced the subjective workload associated with clothespin relocation task ( p < 0.05). However, we found no significant difference in task completion speed, presumably due to compensation strategies. This inexpensive and adaptable prosthetic wrist can be used by amputees to reduce task workload, or by researchers to further explore the importance of wrist function.

3 August 2022 in medRxiv
Verified
Preprint
Open access
PDF file
MPMichael D. Paskett
Michael D. Paskett
JGJhorg K. Garcia
Jhorg K. Garcia
SJSonny T. Jones
Sonny T. Jones
MBMark R. Brinton
Mark R. Brinton
TDTyler S. Davis
Tyler S. Davis
GCGregory A. Clark
Gregory A. Clark
Providing user-focused, objective, and quantified metrics for prosthesis usability may help reduce the high (up to 50%) abandonment rates and accelerate the clinical adoption and cost reimbursement for new and improved prosthetic systems. We comparatively evaluated several physiological, behavioral, and subjective cognitive workload measures applied to upper-limb neuroprosthesis use. Users controlled a virtual prosthetic arm via surface electromyography (sEMG) and completed a virtual target control task at easy and hard levels of difficulty (with large and small targets, respectively). As indices of cognitive workload, we took behavioral (Detection Response Task; DRT) and electroencephalographic (EEG; parietal alpha and frontal theta power, and the P3 event-related potential) measures for one group (n = 1 amputee participant, n = 10 non-amputee participants), and electrocardiographic (ECG; low/high frequency heart-rate variability ratio) and pupillometric (task-evoked pupillary response) measures for another group (n = 1 amputee participant, n = 10 non-amputee participants), because all measures could not reasonably be recorded simultaneously. Participants of both groups also completed the subjective NASA Task-Load Index (TLX) survey. Ease of use, setup, piloting, and analysis complexity varied among measures. The DRT required minimal piloting, was simple to set up, and used straightforward analyses. ECG measures required moderate piloting, were simple to set up, and had somewhat complex analyses. Pupillometric measures required extensive piloting but were simple to set up and relatively simple to analyze. EEG measures required extensive piloting, extensive setup and equipment, careful monitoring, and moderately complex analyses. Across subjects, the DRT, low/high frequency heart-rate variability ratio, task-evoked pupillary response, and NASA TLX significantly differentiated between the easy and hard tasks, whereas EEG measures (alpha power, theta power, and P3 event-related potential) did not. Aside from the NASA TLX, the DRT was the easiest to use and most sensitive to cognitive load across and within subjects. Among physiological measures, we recommend ECG, pupillometry, and EEG/ERPs, in that order. This study provides the first evaluation of multiple objective and quantified cognitive workload measures during the same task with prosthesis use. User-focused cognitive workload assessments may increase our understanding of human interactions with advanced upper-limb neuroprostheses and facilitate their improvements and translation to real-world use. Significance Statement The human arm is dexterous and able to sense objects it contacts. Restoring sensory and motor function to a person with limb loss presents multiple challenges and requires improvements in robotics, biological interfaces, decoding biological signals for prosthesis movement, and sensory restoration. The scientific and engineering communities have made progress toward restoring arm function through advanced neuroprostheses. However, most studies focus solely on task performance, and they typically employ artificial experimental paradigms in which the user can devote full attention to the task, which is often unrealistic for use in everyday activities. To develop neuroprostheses capable of restoring intuitive arm function, engineers and scientists must also consider the difficulty of use, or cognitive burden, of using the neuroprosthesis. Although many measures of cognitive workload have been developed, few studies directly interrogate cognitive workload during neuroprosthesis use. An engineer or scientist seeking to employ cognitive workload measures during neuroprosthesis use will likely wonder, as we did, which measures are most suitable for their needs. To address this question, we empirically assess the practical and functional merits and limitations of several physiological, behavioral, and subjective techniques to measure cognitive workload during use of an advanced prosthesis. We anticipate that these findings may influence other medical and consumer areas of human-computer interaction, such as virtual reality or exoskeleton use.

25 October 2020 in medRxiv
Verified
Preprint
Open access
PDF file
MPMichael D. Paskett
Michael D. Paskett
MBMark R. Brinton
Mark R. Brinton
THTaylor C. Hansen
Taylor C. Hansen
JGJacob A. George
Jacob A. George
TDTyler S. Davis
Tyler S. Davis
GCGregory A. Clark
Gregory A. Clark
Background Advanced prostheses can restore function and improve quality of life for individuals with amputations. Unfortunately, most commercial control strategies do not utilize the rich control information from residual nerves and musculature. Continuous decoders can provide more intuitive prosthesis control from multi-channel neural or electromyographic recordings. Three components influence continuous decoder performance: the data used to train the algorithm, the algorithm, and smoothing filters on the algorithm’s output. As individual groups often focus on a single decoder, very few studies compare different decoders using otherwise similar experimental conditions. Additionally, control improvements are generally demonstrated with offline data or in virtual settings, which do not necessarily translate to real-world performance. Methods We completed a two-phase head-to-head comparison of 12 continuous decoders using activities of daily living. In phase one, we compared two training types and a smoothing filter with three algorithms (modified Kalman filter, multi-layer perceptron, and convolutional neural network) in a clothespin relocation task. We compared training types that included data with only individual digit and wrist movements vs. combination movements (e.g., simultaneous grasp and wrist flexion). We also compared raw vs. nonlinearly smoothed algorithm outputs. In phase two, we compared the three algorithms in fragile egg, zipping, pouring, and folding tasks using the combination training and smoothing found beneficial in phase one. In both phases, we collected objective, performance-based (e.g., success rate) and subjective, user-focused (e.g., preference) measures. Results Phase one showed that combination training improved prosthesis control accuracy and speed, and that the nonlinear smoothing improved accuracy but generally reduced speed. In phase two, user-focused metrics favored the convolutional neural network and modified Kalman filter, while performance-based metrics were generally similar among all algorithms. Conclusions These results confirm that state-of-the-art algorithms, whether linear or nonlinear in nature, functionally benefit from training on more complex data, and demonstrate that smoothing the output improves control. These studies will be used to select a decoder for a long-term take-home trial with implanted neuromyoelectric devices. Overall, clinical considerations may favor the mKF as it is similar in performance, faster to train, and computationally less expensive than neural networks.