Anirban Mazumdar

Anirban Mazumdar

Auto-generated profile, based on publicly available information

Anirban Mazumdar

Georgia Institute of Technology

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 June 2022 in Journal of Mechanisms and Robotics
Verified
Journal Article
Closed access
PDF file
IKInseung Kang
Inseung Kang
RPReese R. Peterson
Reese R. Peterson
KHKinsey R. Herrin
Kinsey R. Herrin
AMAnirban Mazumdar
Anirban Mazumdar
AYAaron J. Young
Aaron J. Young
Series elastic actuators (SEAs) are increasingly popular in wearable robotics due to their high fidelity closed-loop torque control capability. Therefore, it has become increasingly important to characterize its performance when used in dynamic environments. However, the conventional design approach does not fully capture the complexity of the entire exoskeleton system. These limitations stem from identifying design criteria with inadequate biomechanics data, utilizing an off-the-shelf user interface, and applying a benchtop-based proportional-integral-derivative control for actual low-level torque tracking. While this approach shows decent actuator performance, it does not consider human factors such as the dynamic back-driving nature of human-exoskeleton systems as well as soft human tissue dampening during the load transfer. Using holistic design guidelines to improve the SEA-based exoskeleton performance during dynamic locomotion, our final system has an overall mass of 4.8 kg (SEA mass of 1.1 kg) and can provide a peak joint torque of 108 Nm with a maximum velocity of 5.2 rad/s. Additionally, we present a user state-based feedforward controller to further improve the low-level torque tracking for diverse walking conditions. Our study results provide future exoskeleton designers with a foundation to further improve SEA-based exoskeleton’s torque tracking response for maximizing human-exoskeleton performance during dynamic locomotion.

5 October 2021 in IEEE Transactions on Robotics
Verified
Journal Article
Closed access
JLJared M. Li
Jared M. Li
DMDean D. Molinaro
Dean D. Molinaro
AKAndrew S. King
Andrew S. King
AMAnirban Mazumdar
Anirban Mazumdar
AYAaron J. Young
Aaron J. Young
Lumbar spine injuries caused by repetitive lifting rank as the most prevalent workplace injury in the United States. While these injuries are caused by both symmetric and asymmetric lifting, asymmetric is often more damaging. Many back devices do not address asymmetry, so we present a new system called the Asymmetric Back Exosuit (ABX). The ABX addresses this important gap through unique design geometry and active cable-driven actuation. The suit allows the user to move in a wide range of lumbar trajectories while the “X” pattern cable routing allows variable assistance application for these trajectories. We also conducted a biomechanical analysis in OpenSim to map assistive cable force to effective lumbar torque assistance for a given trajectory, allowing for intuitive controller design in the lumbar joint space over the complex kinematic chain for varying lifting techniques. Human subject experiments illustrated that the ABX reduced lumbar erector spinae muscle activation during symmetric and asymmetric lifting by an average of 37.8% and 16.0%, respectively, compared to lifting without the exosuit. This result indicates the potential for our device to reduce lumbar injury risk.

1 November 2019
Verified
Conference Paper
Open access
GNGennaro Notomista
Gennaro Notomista
SMSiddharth Mayya
Siddharth Mayya
AMAnirban Mazumdar
Anirban Mazumdar
SHSeth Hutchinson
Seth Hutchinson
MEMagnus Egerstedt
Magnus Egerstedt
In this paper we present a study of a specific class of vibration-driven robots: the brushbots. In a bottom-up fashion, we start by deriving dynamic models of the brushes and we discuss the conditions under which these models can be employed to describe the motion of brushbots. Then, we present two designs of brushbots: a fully-actuated platform and a differential-drive-like one. The former is employed to experimentally validate both the developed theoretical models and the devised motion control algorithms. Finally, a coordinated-control algorithm is implemented on a swarm of differential-drive-like brushbots in order to demonstrate the design simplicity and robustness that can be achieved by employing a vibration-based locomotion strategy.

5 December 2023 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
ABAakash Bajpai
Aakash Bajpai
CCCarlos Carrasquillo
Carlos Carrasquillo
JCJessica Carlson
Jessica Carlson
JPJulian Park
Julian Park
DIDivya Iyengar
Divya Iyengar
AMAnirban Mazumdar
Anirban Mazumdar
The field of wearable robotics has made significant progress toward augmenting human functions from multimodal ambulation to manual lifting tasks. However, most of these systems are designed to be task-specific and only focus on a single type of movement (e.g., ambulation). In this work, we design, fabricate, and characterize a versatile hip exoskeleton testbed for lifting and ambulation tasks. The exoskeleton testbed is actuated with custom-built quasidirect drive actuators. We produce an orthotic interface to transmit high torques and assemble a custom mechatronic control system for the exoskeleton testbed. We also detail controllers for level ground walking, incline walking, and symmetric knee to waist lifting. We quantify the actuator torque tracking performance quantified through benchtop and human experiments. During knee-to-waist cyclic lifting, the powered condition exhibited a 16.7% reduction in net metabolic cost compared to the no exoskeleton condition (three subjects). For additional tasks (inclined walking, level-walking), the device provided metabolic reductions when compared with the unpowered case (single subject). These testbed results illustrate the potential for versatile hip assistance and can be used to design future optimized devices.

21 February 2020 in IEEE Transactions on Robotics
Verified
Journal Article
Closed access
CHClinton G. Hobart
Clinton G. Hobart
AMAnirban Mazumdar
Anirban Mazumdar
SSSteven J. Spencer
Steven J. Spencer
MQMorgan Quigley
Morgan Quigley
JSJesper P. Smith
Jesper P. Smith
SBStephen Buerger
Stephen Buerger
Legged humanoid robots promise revolutionary mobility and effectiveness in environments built for humans. However, inefficient use of energy significantly limits their practical adoption. The humanoid biped walking anthropomorphic novelly-driven efficient robot for emergency response (WANDERER) achieves versatile, efficient mobility, and high endurance via novel drive-trains and passive joint mechanisms. Results of a test in which WANDERER walked for more than 4 h and covered 2.8 km on a treadmill, are presented. Results of laboratory experiments showing even more efficient walking are also presented and analyzed in this article. WANDERER's energetic performance and endurance are believed to exceed the prior literature in human-scale humanoid robots. This article describes WANDERER, the analytical methods and innovations that enable its design, and system-level energy efficiency results.

3 November 2023 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
CNChristoph Nuesslein
Christoph Nuesslein
KBKrishan Bhakta
Krishan Bhakta
JFJoshua Fernandez
Joshua Fernandez
FDFelicia Davenport
Felicia Davenport
Jennifer LeestmaJennifer Leestma
Jennifer Leestma
AYAaron Young
Aaron Young
Performing heavy manual lifting jobs can be extremely strenuous, often resulting in high rates of injury at overloaded joints. Lower-body exoskeletons have potential to mitigate this fatigue and injury through targeted joint assistance. A variety of current wearable devices aim to provide this kind of support, but their effects on both directly and indirectly targeted joints have not been fully investigated. In this study, a powered bilateral knee exoskeleton (research device), and passive back exosuit (HeroWear Apex) were compared across 10 individuals through a battery of manual lifting tasks. Metabolic, electromyographic, and subject-reported outcome measure data were used to determine which exoskeleton provided the best assistance for each task type. It was found that the knee exoskeleton significantly reduced metabolic cost by 9.6% compared to the no-exoskeleton baseline (p<.05). Both the knee and back exoskeletons reduced activation in up to 6 of the muscles measured (out of 16). Importantly, each device primarily reduced muscle activation around the joint it targeted, not around adjacent joints. These findings suggest that exoskeletons that target the knee or lower back joint during lifting can provide significant assistance in reducing exertion.