Feng Han

Feng Han

Auto-generated profile, based on publicly available information

Feng Han

East China Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Shanghai 200090, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 August 2021 in Molecules
Verified
Journal Article
Open access
PDF file
XZXuan Zhang
Xuan Zhang
YHYunhua Hui
Yunhua Hui
CFChangling Fang
Changling Fang
YWYuan Wang
Yuan Wang
FHFeng Han
Feng Han
Cong KongCong Kong
Cong Kong
A sensitive and reliable method was developed to determine methylene blue (MB) and its metabolite residues, including azure A (AZA), azure B (AZB), and azure C (AZC) in aquatic products by HPLC–MS/MS. The samples were extracted by acetonitrile and cleaned up by alumina-neutral (ALN) cartridges. The analytes were separated on a Sunfire C18 column (150 mm × 2.1 mm, 5 µm). The method was validated according to the European criteria of Commission Decision 2002/657/CE. Good linearity between 1–500 µg/L was obtained with correlation coefficients (R2) greater than 0.99. The limit of quantification (LOQ) was 1.0 µg/kg. The average recoveries at three levels of each compound (1, 5, and 10 µg/kg) were demonstrated to be in the range of 71.8–97.5%, with relative standard deviations (RSDs) from 1.05% to 8.63%. This method was suitable for the detection of methylene blue and its metabolite residues in aquatic products.

11 February 2026 in Foods
Verified
Journal Article
Open access
PDF file
SLSiman Li
Siman Li
FHFeng Han
Feng Han
DHDongmei Huang
Dongmei Huang
JZJingnan Zhang
Jingnan Zhang
YTYunyu Tang
Yunyu Tang
Glucocorticoid (GC) residues present in aquatic products raise food safety concerns, as their chronic dietary intake may pose potential risks of endocrine and metabolic disruption. For the first time, a sensitive and reliable liquid chromatography–tandem mass spectrometry (LC-MS/MS) method was developed and validated herein for the simultaneous determination of 12 GCs residues, including critical isomeric pairs and acetate ester derivatives, in a variety of aquatic foods, employing deuterated isotopic internal standards. Key optimizations included using a pentafluorophenyl column for effective isomer separation, a synergistic extraction system for high recovery, and QuEChERS purification to mitigate matrix effects. The method exhibited excellent linearity (r2 > 0.996) and high accuracy (recoveries 97.3–99.3%), and the intra- and inter-day precision values were below 3% in five representative aquatic matrices, with a limit of detection (LOD) and a limit of quantification (LOQ) of 0.5 μg/kg and 0.75 μg/kg, respectively. Animal experiments confirmed the in vivo retention of acetate derivatives, justifying their inclusion in monitoring. Real sample analysis of 18 market samples revealed the presence of cortisone and hydrocortisone in 17 samples. This represents the first reported LC-MS/MS method that provides a sensitive, reliable tool for regulatory monitoring of GC residues in diverse aquatic products, thereby supporting food safety assurance.