24 November 2017 in IEEE Transactions on Industrial Electronics
This study adopts the method of third-order harmonic voltage injection (THVI) to move the peak value of a reference voltage toward the high capacitor voltage and increase the utilization rate of the capacitor voltage. This method can lower the cost or enlarge the capacity of a modular multilevel converter (MMC) when applied in high-voltage direct-current transmission. In this paper, the principle of THVI is introduced. Two calculation methods for modulation waves are studied, and the mathematical expressions of the capacitor voltage under all operating conditions are deduced. Thus, the optimal magnitude and phase of the third-order harmonic voltage are determined under all operating conditions. The mathematical expressions of the optimal magnitude and phase of the third-order harmonic voltage are obtained, and their online calculation burden is reduced. Simulation and experimental results show that the proposed method of THVI is feasible and effective.
3 July 2017 in IEEE Transactions on Power Electronics
This study proposed a novel modular multilevel converter (MMC) based on unidirectional current H-bridge submodule (UCH-SM) with active circulating current injection (ACCI). Under the premise of keeping the arm current unidirectional, the UCH-SM was developed by optimizing the full-bridge submodule (FBSM). Although the number of required switching devices of the UCH-SM-based MMC (UCH-MMC) is nearly half of that of FBSM-based MMC (FB-MMC), the advantages of the FB-MMC, such as the dc fault blocking and bidirectional dc-link voltage capabilities, were preserved. The proposed ACCI technique can help keep the arm current unidirectional and reduce the overall semiconductor usage. The parameter design method for keeping the arm current unidirectional and the characteristics of the UCH-MMC with ACCI were also analyzed. The control schemes of the UCH-MMC for the dc-link voltage control and dc-link current control modes were presented. Simulation and experimental results were presented to verify the feasibility and characteristics of the proposed UCH-MMC.
13 December 2018 in IEEE Transactions on Industrial Electronics
To provide a reliable approach that can significantly decrease energy storage requirements, this paper proposes a low-capacitance modular multilevel converter (MMC) operating with high capacitor voltage ripples. In the proposed MMC with high ripples (HR-MMC), the dc value of the capacitor voltage is slightly decreased by slightly increasing the number of series-connected submodules in each arm. Therefore, the MMC can operate under a higher capacitor voltage ripple without changing the peak capacitor voltage. Evaluation shows that the cost and volume of the HR-MMC can be reduced due to the reduction of energy storage requirements. The volume reduction effect is particularly obvious. The impacts of the capacitor voltage ripple on the linear modulation region are also analyzed. The obtained active and reactive power diagram shows that the active power and capacitive reactive power ratings are not affected by the high capacitor voltage ripple. The high capacitor voltage ripple only results in a reduction of inductive reactive power rating. The correctness of the theoretical analysis and the feasibility of the HR-MMC were verified through simulations and experiments.
10 September 2018 in IEEE Transactions on Power Electronics
Utilization of negative voltage states substantially reduces the energy storage requirements of a full-bridge sub-module-based modular multilevel converter (FB-MMC). This study provides a detailed analysis of the capacitor voltage ripple and energy storage requirement reduction effects of the FB-MMC by utilizing negative voltage states. The analytical expressions of capacitor voltage ripple following the change in negative voltage state factor (NVSF) are derived. Results show that the capacitor voltage ripple reduction effects using negative voltage states is strongly correlated with the operated power factor angle. In addition, the second-order ripple component must be considered to increase the accuracy in evaluating the voltage ripple reduction effects. This study defines the energy storage reduction factor (ESRF) to indicate the level at which the energy storage requirement can be minimized by selecting an appropriate NVSF for a given permitted operating range of the power factor angle. The curve of the ESRF following the change in the permitted operating range of the power factor angle was calculated. The analytical method and the evaluation results for the capacitor voltage and energy storage reduction effects of the FB-MMC using negative voltage states are verified on the basis of the simulation and experimental results.
8 December 2019 in IEEE Transactions on Power Electronics
Hybrid modular multilevel converter that consists of a combination of half-bridge submodules and full-bridge submodules (FBSMs) can block dc fault current. However, in the case of distant bulk power transmission, the large excess energy that stored in the long-distance line will greatly affect the fault clearing time and FBSM capacitor overvoltage. During the fault clearing process, several commutations of the fault current from one arm to another may occur during the fault clearing process. A dynamic model, in which the commutations of the fault current are considered, is proposed to describe the fault clearing process after converter blocking in precise detail. The fault clearing time and FBSM overvoltage can be exactly estimated. The analytical analysis model is verified by the simulation and experimental results.
11 April 2019 in IEEE Transactions on Power Electronics
Unidirectional current H-bridge modular multilevel converter (UCH-MMC) is a variant of full-bridge MMC and uses fewer semiconductor devices. The operating area and operation mode of UCH-MMC differ from those of conventional half-bridge MMC (HB-MMC) because of the unidirectional current and bipolar voltage of UCH-MMC arms. Thus, analyzing the energy storage requirement (ESR) of UCH-MMC differs from that of HB-MMC. This paper proposes a model for calculating the ESR of UCH-MMC. The ESR of the UCH-MMC under the entire operating area is analyzed. A modified operating scheme that dynamically trims the sub-module capacitor voltage to allow the low capacitance operation under the entire operating area is proposed. Results verify that the UCH-MMC has much lower ESR than HB-MMC. Evaluation results also show that the cost and volume of the UCH-MMC are much lower than those of HB-MMC because of the low ESR. The low ESR of UCH-MMC was verified by simulations and experiments.