25 May 2022 in IEEE Transactions on Instrumentation and Measurement
A new method is proposed for reducing the error of thermocouples in measuring the surface temperature of blades with cooling film. Both the measurement error and the conduction error of film cooling blade surface temperature were numerically investigated. Benefited from the optimized thermocouple fixation mode, the temperature measurement error can be reduced by 40% at least. The temperature measurement errors of surface fixed model and groove fixed model were analyzed and compared. Furthermore, the effects of different head gaps, film thickness and film temperature on the temperature measurement error are described in detail. Under the optimal parameters, the temperature measurement error of thermocouples can be decreased by 99.5%. Finally, the groove fixed model is studied experimentally and the results show that the temperature measurement error can be reduced by 99.83% under the optimal groove depth, which is in good agreement with the simulation results. This error analysis and reduction method attaches great significance to the improvement in the temperature measurement accuracy of turbine blades, as well as the research of new temperature measurement methods.
16 September 2024 in IEEE Transactions on Instrumentation and Measurement
Turbine blades are the core components of aeroengines, and the measurement of the blade surface temperature field is a top priority in aeroengine design, development, and health monitoring. In this article, a fiber optic array temperature field measurement system for high-temperature turbine blades is proposed. First, a high-temperature resistant probe was designed by using sapphire fiber arrays. Then, an array temperature field measurement system was built based on the principle of colorimetric thermometry. Finally, temperature field measurement experiments of blades are conducted by building a high-temperature field rotor test rig. The experimental results show that the maximum temperature measurement error of the system is 0.96% in the temperature measurement range of 1400–2000 K, and according to the proposed temperature field reconstruction algorithm, the 3-D temperature field reconstruction of the blade is achieved.
18 August 2023 in IEEE Sensors Journal
We propose a novel framework for optimized evaluation to address the challenging problem in aeroengine such as the positioning of pyrometer featured with multi-channel. Using COMSOL Multiphysics in combination with MATLAB, we have implemented the turbine blade radiometric temperature scanning area positioning, pyrometer temperature measurement target resolution analysis and multi-channel pyrometer positioning and evaluation through the careful selection of evaluation indexes. The overall performance of the proposed framework as well as the effectiveness of each function were evaluated through experimental cases. After positioning and installing the pyrometer in this way, it will exert its optimal temperature measurement performance. This approach will guide the development direction of pyrometer positioning research in the future.
28 April 2023 in IEEE Transactions on Instrumentation and Measurement
A new method is proposed for correcting the error of monochromatic method in measuring the surface temperature of turbine blades with the influence of reflection. The measurement error caused by surrounding components were numerically investigated. The effects of background temperature, adjacent rotor blades, front stator vanes and rear stator vanes on the temperature measurement error are described in detail. Furthermore, the corrected errors of high emissivity and low emissivity are compared and analyzed and the influence of the relative displacement between the turbine blade and the hot-end component on the temperature measurement error is also discussed. Benefiting from the proposed radiation-based error correction method (RECM), we can reduce the monochromatic temperature measurement error to less than 0.3 % at high emissivity and less than 0.8% at low emissivity theoretically. Finally, the RECM method is studied experimentally, and the results show that the temperature measurement error can be corrected to better than 0.6%, which is in good agreement with the Monte Carlo simulation results.
11 September 2023 in IEEE Transactions on Instrumentation and Measurement
This study develops a methodology to eliminate the reflected radiation in measuring the surface temperature of turbine blades by combining experimental measurements and simulations, and calibrating and validating the computational models with experimental measurements. The influences of reflected radiation caused by the front and rear stator vanes, adjacent rotor blades and background temperature on temperature measurement error of the target blade are systematically demonstrated through simulation. And the temperature measurement errors of monochromatic method and colorimetric method under the same conditions are compared. Then the corrections on temperature measurement error are carried out under static and moving conditions. Detailed uncertainty analysis is simulated through Monte Carlo method. Finally, a simplified experiment is carried out, and the results are consistent with the simulation results. This study will open a new avenue of eliminating reflected radiation error and mechanism research for the temperature measurements of the turbine blades.
10 October 2026 in European Heart Journal - Digital Health
Aims: Identifying the infarct-related artery (IRA) before coronary angiography in non–ST-segment elevation myocardial infarction (NSTEMI) is difficult because current approaches have limited sensitivity. We evaluated whether a non-invasive 90-s optically pumped magnetometer magnetocardiography (OPM-MCG) recording can estimate pre-angiography IRA probabilities in these patients and provide information beyond standard-care variables. Methods and results: This prospective two-campus study within one hospital system included a Campus 1 development cohort (n = 493) and a geographically separate Campus 2 test cohort (n = 118). All patients underwent OPM-MCG before angiography. An XGBoost model using 65 prespecified OPM-MCG features was developed with nested cross-validation, locked, and evaluated once in Campus 2. IRA adjudication followed a core-laboratory hierarchy. Discrimination, calibration, and clinical utility were compared with ECG and TTE. Among 611 patients, 43% had LAD, 23% LCx, and 34% RCA IRA. In Campus 2, overall accuracy was 63.6%, macro-F1 was 60.0%; LAD/LCx/RCA vessel-specific areas under the receiver operating characteristic curve were 0.87/0.79/0.79 and top-1 sensitivity was 76.6%/34.5%/69.0%. Accuracy was 51.7% for matched ECG-only XGBoost and 55.9% for integrated standard care. In an exploratory stacked analysis, adding locked OPM-MCG probabilities to standard care increased accuracy to 67.8% (paired difference 11.9%, 95% CI 4.2–19.5; P = 0.008). Conclusion: In haemodynamically stable patients with NSTEMI already selected for invasive management, a locked OPM-MCG model provided informative vessel-level probabilities in Campus 2 and complementary signal with standard care. Performance was strongest for LAD and RCA. Prospective multicentre, cross-platform testing is needed before clinical use. Trial registration number: ChiCTR2300070211.