Chang Sun

Chang Sun

Auto-generated profile, based on publicly available information

Chang Sun

School of Instrument Science and Opto-electronics Engineering, Beihang University, Beijing, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 February 2021 in Optics Express
Verified
Journal Article
Open access
PDF file
BXBozheng Xing
Bozheng Xing
CSChang Sun
Chang Sun
ZLZiao Liu
Ziao Liu
JZJunpeng Zhao
Junpeng Zhao
JLJixi Lu
Jixi Lu
MDMing Ding
Ming Ding
In the spin-exchange relaxation-free (SERF) magnetometer, the probe noise is a consequential factor affecting the gradiometric measurement sensitivities. In this paper, we proposed a new characteristics model of the probe noise based on noise separation. Different from noise analysis on single noise source, we considered most of the noise sources influencing the probe system and realized noise sources level measurement experimentally. The results demonstrate that the major noise type changes with the signal frequency. Below 10 Hz, the probe noise mainly comes from the sources independent of light intensity such as the vibration, which accounts for more than 50%; while at 30 Hz, the photon shot noise and the magnetic noise are the main origins, with proportion about 43% and 32%, respectively. Moreover, the results indicate that the optimal probe light intensity with highest sensitivity appears when the response of the magnetic noise is equal to the sum of the electronic noise and half of the shot noise. The optimal intensity gets larger with higher signal frequency. The noise characteristics model could be applied in modulating or differential optical systems and helps sensitivity improvement in SERF magnetometer.

8 April 2021 in Environmental Monitoring and Assessment
Verified
Journal Article
Open access
PDF file
LLLei Liu
Lei Liu
XMXin Ma
Xin Ma
WWWei Wen
Wei Wen
CSChang Sun
Chang Sun
JJJiao Jiao
Jiao Jiao
Linfen in China’s Shanxi Province suffers severe air pollution in winter. Understanding the characteristics of air pollution and providing scientific support to mitigate such pollution are urgent matters. This study investigated the variations of PM2.5, PM10, NO2, SO2, O3, and CO in Linfen between December 1, 2019 and February 29, 2020. The mean concentrations of PM2.5, PM10, NO2, SO2, MDA8 (the maximum daily 8-h average) O3, and CO were 106.2, 139.4, 47.2, 41.0, 57.0 μg m−3, and 1.8 mg m−3, respectively. Large amounts of pollutants emitted by coal burning, industry, vehicles, and residents contributed to air pollution. Unfavorable meteorological conditions, such as lower temperature, weaker wind, higher relative humidity, and reduced planetary boundary layer height, made the situation worse. Fireworks and firecrackers set off to celebrate traditional Chinese festivals caused the concentration of PM pollutants to spike, with the maximum daily mean concentration of PM2.5 reached 314 μg m−3 and the peak hourly value reached 378.0 μg m−3. Suspensions of commercial and social activities due to COVID-19 reduced anthropogenic emissions, mainly from industry and transportation, which decreased the level of air pollutants other than O3. Analyses involving backward trajectory cluster, the potential source contribution function, and concentration weighted trajectory demonstrated that PM2.5 pollution mainly came from local emissions in Shanxi Province and regional transport from Inner Mongolia, Shaanxi, Hebei, Henan, and Gansu provinces. Shanxi and its surrounding provinces should adopt measures such as tightening environmental management standards, promoting the use of renewable energy, and adjusting the transportation structure to reduce regional emissions. This study will help policy-makers draft plans and policies to reduce air pollution in Linfen.

19 January 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SLSiran Li
Siran Li
Jixi LuJixi Lu
Jixi Lu
DMDanyue Ma
Danyue Ma
KWKun Wang
Kun Wang
YGYanan Gao
Yanan Gao
BHBangcheng Han
Bangcheng Han
An in situ method has been proposed for measuring all nonorthogonal angles of the beams and triaxial coils in a three-axis vector optically pumped magnetometer (OPM). Based on the combination and alignment of two pump beams, each of which can achieve biaxial transverse measurement in a time-sharing regime under modulated magnetic fields, a 3-D orthogonal coordinate measurement system is obtained, and the measurement models for three categories (six types) of nonorthogonal angles are established theoretically. On this basis, we experimentally measured the nonorthogonal angles along with related uncertainties at different modulated frequencies and strengths of the magnetic fields. The nonorthogonal angles were (3.65° ± 0.52°) between the two pump beams before compensation. They were (7.05° ± 0.23°) between the $X$ - and $Y$ -axis coils, (8.89° ± 0.21°) between the $Y$ - and $Z$ -axis coils, (5.23° ± 0.27°) between the $X$ - and $Z$ -axis coils, (7.24° ± 0.24°) between the $x$ -direction pump beam and $X$ -axis coil, and (9.10° ± 0.22°) between the $z$ -direction pump beam and the $Z$ -axis coil. This study measures the magnitudes of six types of nonorthogonality, without making an assumption of ideal orthogonality or using auxiliary calibration equipment. Moreover, this method can be extended to several other kinds of OPMs with simple modifications. This study is critical for evaluating and reducing the misalignment error to improve the accuracy of three-axis vector OPMs.

20 January 2022 in Optics Express
Verified
Journal Article
Closed access
BXBozheng Xing
Bozheng Xing
JLJixi Lu
Jixi Lu
CSChang Sun
Chang Sun
TYTingting Yu
Tingting Yu
YWYue Wu
Yue Wu
BHBangcheng Han
Bangcheng Han
We analyze and suppress the magnetic noise response in optical rotation detection system (ORDS) in atomic magnetometers in this study. Because of the imperfections of the optical elements, the probe light is actually elliptically polarized in ORDS, which can polarize the atom ensemble and cause the responses to the three-axis magnetic noise. We theoretically analyze the frequency responses to the magnetic noise, and prove that the responses are closely associated with the DC magnetic field. The values of the DC magnetic fields are calculated with special frequency points, called ‘break points’, in the transverse responses. We reveal the relationships between the DC magnetic field and the sensitivities of ORDS, and effectively suppress the magnetic noise responses with the residual magnetic field compensation. Finally, the sensitivity of ORDS is improved by approximately two times at 10-20 Hz.

18 March 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JZJian Zhu
Jian Zhu
BWBo-Tao Wang
Bo-Tao Wang
CSChang Sun
Chang Sun
MDMing Ding
Ming Ding
In this paper, a sapphire fiber colorimetric thermometry system is used to achieve high-precision measurement of ultrahigh-temperature up to 2000K by correcting the reflected radiation error. Based on the principle of colorimetric temperature measurement, a radiometric thermometry system is constructed using sapphire fiber with a high melting point. Reflection errors on ceramic blades in high-temperature furnaces are eliminated by calibrating the reflected radiation. The experimental results show that the temperature measurement error of the sapphire fiber colorimetric thermometry system is less than 1% in the range of 1400-2000K. And the repeatability error of the experiment is ±0.9%, which achieves the high-precision measurement of ultrahigh-temperature by correcting the reflection error.

17 May 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JZJian Zhu
Jian Zhu
BWBo-Tao Wang
Bo-Tao Wang
TLTao Liang
Tao Liang
YYYu Yang
Yu Yang
CSChang Sun
Chang Sun
MDMing Ding
Ming Ding
In this paper, a high precision correction method for temperature measurement errors due to reflected radiation under high temperature background is reported by applying calibration experiments. The correction theory governing the temperature measurement errors caused by reflected radiation is derived in principle, and the physical field model of temperature measurement is established for a ceramic blade in a high temperature furnace. The temperature measurement errors before and after the correction of the reflected radiation are analyzed through simulations, and the reflected radiation in the temperature measurement environment of the blade is calibrated. The experimental results show that the errors of monochromatic and colorimetric temperature measurements are decreased from 13.5% and 7.5% to 0.3% and 0.5%, respectively. The results indicate that the proposed method can significantly decrease the temperature measurement errors caused by reflected radiation.