Yu Yang

Yu Yang

Auto-generated profile, based on publicly available information

Yu Yang

School of Instrument Science and Opto-electronics Engineering, Beihang University, Beijing, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 July 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
BWBo-Tao Wang
Bo-Tao Wang
YNYanxiong Niu
Yanxiong Niu
YYYu Yang
Yu Yang
TLTao Liang
Tao Liang
XQXu-Dong Qin
Xu-Dong Qin
MDMing Ding
Ming Ding
A colorimetric high-temperature sensor based on a sapphire fiber bundle is reported in this work. The radiation voltage ratio of two neighboring wavelengths is used to detect the temperature. The sapphire fiber bundle can increase the efficiency of radiation light collection. To improve mechanical properties and structural stability, the sensor probe is encased in a ceramic tube. Experimental results show that the sensor can be used in a wide temperature range of 648–1800 K with a measuring accuracy range from 0.4% to 1.8%. The sapphire fiber colorimetric high-temperature sensor effectively reduces the effects of various types of interferences in the measurement process because of the calibration procedure. In the field of high-temperature sensing, the proposed colorimetric sapphire fiber high-temperature sensor offers various application potentials.

17 May 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JZJian Zhu
Jian Zhu
BWBo-Tao Wang
Bo-Tao Wang
TLTao Liang
Tao Liang
YYYu Yang
Yu Yang
CSChang Sun
Chang Sun
MDMing Ding
Ming Ding
In this paper, a high precision correction method for temperature measurement errors due to reflected radiation under high temperature background is reported by applying calibration experiments. The correction theory governing the temperature measurement errors caused by reflected radiation is derived in principle, and the physical field model of temperature measurement is established for a ceramic blade in a high temperature furnace. The temperature measurement errors before and after the correction of the reflected radiation are analyzed through simulations, and the reflected radiation in the temperature measurement environment of the blade is calibrated. The experimental results show that the errors of monochromatic and colorimetric temperature measurements are decreased from 13.5% and 7.5% to 0.3% and 0.5%, respectively. The results indicate that the proposed method can significantly decrease the temperature measurement errors caused by reflected radiation.

16 September 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JZJian Zhu
Jian Zhu
BWBo-Tao Wang
Bo-Tao Wang
JJJie Ji
Jie Ji
YZYixiang Zhang
Yixiang Zhang
YYYancheng Yu
Yancheng Yu
MDMing Ding
Ming Ding
Turbine blades are the core components of aeroengines, and the measurement of the blade surface temperature field is a top priority in aeroengine design, development, and health monitoring. In this article, a fiber optic array temperature field measurement system for high-temperature turbine blades is proposed. First, a high-temperature resistant probe was designed by using sapphire fiber arrays. Then, an array temperature field measurement system was built based on the principle of colorimetric thermometry. Finally, temperature field measurement experiments of blades are conducted by building a high-temperature field rotor test rig. The experimental results show that the maximum temperature measurement error of the system is 0.96% in the temperature measurement range of 1400–2000 K, and according to the proposed temperature field reconstruction algorithm, the 3-D temperature field reconstruction of the blade is achieved.

28 April 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JJJie Ji
Jie Ji
BWBo-Tao Wang
Bo-Tao Wang
YYYu Yang
Yu Yang
TLTao Liang
Tao Liang
MDMing Ding
Ming Ding
A new method is proposed for correcting the error of monochromatic method in measuring the surface temperature of turbine blades with the influence of reflection. The measurement error caused by surrounding components were numerically investigated. The effects of background temperature, adjacent rotor blades, front stator vanes and rear stator vanes on the temperature measurement error are described in detail. Furthermore, the corrected errors of high emissivity and low emissivity are compared and analyzed and the influence of the relative displacement between the turbine blade and the hot-end component on the temperature measurement error is also discussed. Benefiting from the proposed radiation-based error correction method (RECM), we can reduce the monochromatic temperature measurement error to less than 0.3 % at high emissivity and less than 0.8% at low emissivity theoretically. Finally, the RECM method is studied experimentally, and the results show that the temperature measurement error can be corrected to better than 0.6%, which is in good agreement with the Monte Carlo simulation results.

9 December 2022 in Measurement Science and Technology
Verified
Journal Article
Closed access
YYYu Yang
Yu Yang
YNYanxiong Niu
Yanxiong Niu
BWBo-Tao Wang
Bo-Tao Wang
TLTao Liang
Tao Liang
MDMing Ding
Ming Ding
A method to improve the spatial resolution of the radiant optical fiber temperature sensor is proposed in this paper. The front lens of the sensor is designed to limit the diameter of the thermometry target. In order to avoid limiting the influence of the thermometry target diameter on the sensor radiation-light coupling ability, a mathematical model of the radiation-light coupling of the sensor is established, and the relationship between the radiation-light coupling ability of the sensor and the diameter of the thermometry target is analyzed. Furthermore, an aspheric lens is applied to reduce the influence of aberration on the diameter of the thermometry target. The experimental results show that the deviation between the actual temperature measuring target diameter and the theoretical design value is less than 0.2 mm. The radiation received by the sensor outside the temperature measuring target is less than 10% of its total received radiation. Moreover, when there is radiated light interference outside the temperature measurement target, the temperature measurement error of the sensor is only 0.21%–2.61%, indicating that the proposed method has practical significance in improving the spatial resolution of the temperature measurement.