Jakub Sroubek

Jakub Sroubek

Auto-generated profile, based on publicly available information

Jakub Sroubek

Cardiac Electrophysiology Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio, USA

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2021 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
PDF file
HYHagai D. Yavin
Hagai D. Yavin
KHKoji Higuchi
Koji Higuchi
JSJakub Sroubek
Jakub Sroubek
AYArwa Younis
Arwa Younis
IZIsrael Zilberman
Israel Zilberman
EAElad Anter
Elad Anter
Background: Pulsed-field ablation (PFA) is a rapid and nonthermal energy with higher selectivity to myocardial tissue in comparison to radiofrequency ablation. However, its effects on ventricular myocardium and titration of lesion dimensions have not been well studied. This study examined the effect of PFA on ventricular myocardium and the influence of application repetition on lesion dimensions. Methods: An 8-Fr lattice catheter with a compressible 9-mm nitinol tip was used with a PFA generator (Affera, Inc) applying a bipolar and biphasic waveform (±1.3–2.0 kV, 4 second per application). We examined the impact of single applications (1×) versus 4 repetitive applications (4×) interspaced by 10 seconds. The latter was performed to determine whether repetitions of a similar electrical field can increase lesion dimensions. Experiments were performed in an in vivo porcine model and a survival period of 24 hours (n=6) or 23±5.4 days (n=6) for evaluation of early and late histopathologic effects. Results: PFA in ventricular myocardium showed repetition dependency. Acute lesion depth and volume increased from 5.6±1.43 mm and 860±362 mm3 to 8.8±0.74 mm and 2383±548 mm3 for 1× and 4× applications, respectively ( P <0.001 for both comparisons). This effect was maintained in the chronic lesion phase with lesion depth and volume of 3.9±0.92 mm and 655±286 mm3 compared with 7.3±0.83 mm and 2170±488 mm3, respectively ( P <0.001 for both comparisons). Acute lesions showed well demarcated necrotic core without coagulation necrosis while chronic lesions showed tissue thinning with fibro-fatty replacement. Conclusions: PFA in ventricular myocardium exhibits repetition dependency as lesion dimension increases with consecutive applications of a similar electrical field.

1 January 2024 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
HNHiroshi Nakagawa
Hiroshi Nakagawa
QCQuim Castellvi
Quim Castellvi
RIRobert Evans Neal II
Robert Evans Neal II
SGSteven Girouard
Steven Girouard
JLJacob Laughner
Jacob Laughner
OWOussama M. Wazni
Oussama M. Wazni
Background: Effects of contact force (CF) on lesion formation during pulsed field ablation (PFA) have not been well validated. The purpose of this study was to determine the relationship between average CF and lesion size during PFA using a swine-beating heart model. Methods: A 7F catheter with a 3.5-mm ablation electrode and CF sensor (TactiCath SE, Abbott) was connected to a PFA system (CENTAURI, Galvanize Therapeutics). In 5 closed-chest swine, biphasic PFA current was delivered between the ablation electrode and a skin patch at 40 separate sites in right ventricle (28 Amp) and 55 separate sites in left ventricle (35 Amp) with 4 different levels of CF: (1) low (CF range of 4–13 g; median, 9.5 g); (2) moderate (15–30 g; median, 21.5 g); (3) high (34–55 g; median, 40 g); and (4) no electrode contact, 2 mm away from the endocardium. Swine were sacrificed at 2 hours after ablation, and lesion size was measured using triphenyl tetrazolium chloride staining. In 1 additional swine, COX (cytochrome c oxidase) staining was performed to examine mitochondrial activity to delineate reversible and irreversible lesion boundaries. Histological examination was performed with hematoxylin and eosin and Masson trichrome staining. Results: Ablation lesions were well demarcated with triphenyl tetrazolium chloride staining, showing (1) a dark central zone (contraction band necrosis and hemorrhage); (2) a pale zone (no mitochondrial activity and nuclear pyknosis, indicating apoptosis zone); and a hyperstained zone by triphenyl tetrazolium chloride and COX staining (unaffected normal myocardium with preserved mitochondrial activity, consistent with reversible zone). At constant PFA current intensity, lesion depth increased significantly with increasing CF. There were no detectable lesions resulting from ablation without electrode contact. Conclusions: Acute PFA ventricular lesions show irreversible and reversible lesion boundaries by triphenyl tetrazolium chloride staining. Electrode-tissue contact is required for effective lesion formation during PFA. At the same PFA dose, lesion depth increases significantly with increasing CF.

1 October 2022 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
PDF file
AYArwa Younis
Arwa Younis
IZIsrael Zilberman
Israel Zilberman
AKAlison Krywanczyk
Alison Krywanczyk
KHKoji Higuchi
Koji Higuchi
HYHagai D. Yavin
Hagai D. Yavin
EAElad Anter
Elad Anter
Background: Pulsed-field ablation (PFA) is a nonthermal energy with higher selectivity to myocardial tissue in comparison to radiofrequency ablation (RFA). We compared the effects of PFA and RFA on heterogeneous ventricular scar in a swine model of healed infarction. Methods: In 9 swine, myocardial infarction was created by balloon occlusion of the left anterior descending artery. After a survival period of 8 to 10 weeks, ablation with PFA or RFA was performed at infarct border zones identified by abnormal electrograms. In the PFA group (4 swine), ablation was performed with a lattice catheter (Sphere-9, Affera, Inc). In the RFA group (5 swine), ablation was performed using a 3.5-mm tip catheter (Thermocool ST-SF; Biosense Webster). To further investigate the effect of RFA on temperature development in scar tissue, intramyocardial temperature was measured in healthy and infarcted myocardium using an ex vivo bath model. Results: A total of 11 PFA and 15 RFA lesions were created at infarct border zones with heterogeneous scar. PFA produced uniform and well-demarcated lesions exhibiting irreversible injury characterized by cardiomyocyte death, contraction bands, and lymphocytic infiltration. This effect of PFA extended from the subendocardium through collagen and fat to the epicardial layers. In contrast, the effect of RFA is less uniform and largely limited to the subendocardium with minimal effect on viable myocardium deeper to separating layers of collagen and fat. PFA produced deeper and more transmural lesions (6.4 [interquartile range, 5.5–7.5) versus 5.4 [interquartile range, 4.8–5.9]), 72% versus 30%, respectively; P ≤0.02 for each comparison). The limited effect of RFA on viable myocardium at deeper infarct layers was related to a lower intramyocardial maximal temperature compared with healthy myocardium ( P =0.01). Conclusions: PFA may be advantageous for ablation in ventricular scar, producing lesions that unlike RFA are not limited to the subendocardium, but also eliminate viable myocardium separated from the catheter by collagen and fat.

1 June 2020 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
PDF file
HYHagai Yavin
Hagai Yavin
ASAyelet Shapira-Daniels
Ayelet Shapira-Daniels
MBMichael Barkagan
Michael Barkagan
JSJakub Sroubek
Jakub Sroubek
DSDavid Shim
David Shim
EAElad Anter
Elad Anter
Background: Pulsed field ablation (PFA) is a nonthermal energy that may provide safety advantages over radiofrequency ablation (RFA). One-shot PFA catheters have been developed for pulmonary vein isolation, but they do not permit flexible lesion sets. This study investigated a novel lattice-tip catheter designed for focal RFA or PFA ablation. Methods: The effects of PFA (biphasic, 24 amperes) were investigated in 25 swine using a lattice-tip catheter and system (Affera Inc). Step 1 (n=14) examined the feasibility to create atrial line of block and described its acute effects on the phrenic nerve and esophagus. Step 2 (n=7) examined the subacute effects of PFA on block durability, phrenic nerve, and esophagus ≥2 weeks. Step 3 compared the effects of PFA and RFA on the esophagus using a mechanical deviation model approximating the esophagus to the right atrium (n=4) and by direct ablation within its lumen (n=4). The effects of endocardial PFA and RFA on the phrenic nerve were also compared (n=10). Histological analysis was performed. Results: PFA produced acute block in 100% of lines, achieved with 2.1 (1.3–3.2) applications/cm line. Histological analysis following (35 [18–37]) days showed 100% transmurality (thickness range 0.4–3.4 mm) with a lesion width of 19.4 (10.9–27.4 mm). PFA selectively affected cardiomyocytes but spared blood vessels and nervous tissue. PFA applied from the posterior atria (23 [21–25] applications) to the approximated esophagus (6 [4.5–14] mm) produced transmural lesions without esophageal injury. PFA (16.5 [15–18] applications) applied inside the esophageal lumen produced mild edema compared with RFA (13 [12–14] applications) which produced epithelial ulcerations. PFA resulted in no or transient stunning of the phrenic nerve (<5 minutes) without histological changes while RFA produced paralysis. Conclusions: PFA using a lattice-tip ablation catheter for focal ablation produced durable atrial lesions and showed lower vulnerability to esophageal or phrenic nerve damage compared with RFA.

6 May 2020 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
PDF file
EAElad Anter
Elad Anter
PNPetr Neuzil
Petr Neuzil
VRVivek Y. Reddy
Vivek Y. Reddy
JPJan Petru
Jan Petru
KPKyoung-Min Park
Kyoung-Min Park
AWAndrew L. Wit
Andrew L. Wit
Background: The optimal method to identify the arrhythmogenic substrate of scar-related ventricular tachycardia (VT) is unknown. Sites of activation slowing during sinus rhythm (SR) often colocalize with the VT circuit. However, the utility and limitations of such approach for guiding ablation are unknown. Methods: We conducted a multicenter study in patients with infarct-related VT. The left ventricular (LV) was mapped during activation from 3 directions: SR (or atrial pacing), right ventricular, and LV pacing at 600 ms. Ablation was applied selectively to the cumulative area of slow activation, defined as the sum of all regions with activation times of ≥40 ms per 10 mm. Hemodynamically tolerated VTs were mapped with activation or entrainment. The primary outcome was a composite of appropriate implanted cardioverter-defibrillator therapies and cardiovascular death. Results: In 85 patients, the LV was mapped during activation from 2.4±0.6 directions. The direction of LV activation influenced the location and magnitude of activation slowing. The spatial overlap of activation slowing between SR and right ventricular pacing was 84.2±7.1%, between SR and LV pacing was 61.4±8.8%, and between right ventricular and LV pacing was 71.3±9.6% ( P <0.05 between all comparisons). Mapping during SR identified only 66.2±8.2% of the entire area of activation slowing and 58% critical isthmus sites. Activation from other directions by right ventricular and LV stimulation unmasked an additional 33% of slowly conducting zones and 25% critical isthmus sites. The area of maximal activation slowing often corresponded to the site where the wavefront first interacted with the infarct. During a follow-up period of 3.6 years, the primary end point occurred in 14 out of 85 (16.5%) patients. Conclusions: The spatial distribution of activation slowing is dependent on the direction of LV activation with the area of maximal slowing corresponding to the site where the wavefront first interacts with the infarct. This data may have implications for VT substrate mapping strategies.

5 February 2019 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
PDF file
JSJakub Sroubek
Jakub Sroubek
MRMarkus Rottmann
Markus Rottmann
MBMichael Barkagan
Michael Barkagan
Eran LeshemEran Leshem
Eran Leshem
ASAyelet Shapira‐Daniels
Ayelet Shapira‐Daniels
EAElad Anter
Elad Anter