Pasi Liljeberg

Pasi Liljeberg

Auto-generated profile, based on publicly available information

Pasi Liljeberg

University of Turku

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 June 2016 in Journal of Ambient Intelligence and Humanized Computing
Verified
Journal Article
Closed access
PDF file
IAIman Azimi
Iman Azimi
ARAmir M. Rahmani
Amir M. Rahmani
PLPasi Liljeberg
Pasi Liljeberg
Hannu TenhunenHannu Tenhunen
Hannu Tenhunen

18 January 2022 in Journal of Medical Internet Research
Verified
Journal Article
Open access
RCRui Cao
Rui Cao
IAIman Azimi
Iman Azimi
Fatemeh SarhaddiFatemeh Sarhaddi
Fatemeh Sarhaddi
HNHannakaisa Niela-Vilen
Hannakaisa Niela-Vilen
AAAnna Axelin
Anna Axelin
ARAmir Rahmani
Amir Rahmani
Background: Photoplethysmography is a noninvasive and low-cost method to remotely and continuously track vital signs. The Oura Ring is a compact photoplethysmography-based smart ring, which has recently drawn attention to remote health monitoring and wellness applications. The ring is used to acquire nocturnal heart rate (HR) and HR variability (HRV) parameters ubiquitously. However, these parameters are highly susceptible to motion artifacts and environmental noise. Therefore, a validity assessment of the parameters is required in everyday settings. Objective: This study aims to evaluate the accuracy of HR and time domain and frequency domain HRV parameters collected by the Oura Ring against a medical grade chest electrocardiogram monitor. Methods: We conducted overnight home-based monitoring using an Oura Ring and a Shimmer3 electrocardiogram device. The nocturnal HR and HRV parameters of 35 healthy individuals were collected and assessed. We evaluated the parameters within 2 tests, that is, values collected from 5-minute recordings (ie, short-term HRV analysis) and the average values per night sleep. A linear regression method, the Pearson correlation coefficient, and the Bland–Altman plot were used to compare the measurements of the 2 devices. Results: Our findings showed low mean biases of the HR and HRV parameters collected by the Oura Ring in both the 5-minute and average-per-night tests. In the 5-minute test, the error variances of the parameters were different. The parameters provided by the Oura Ring dashboard (ie, HR and root mean square of successive differences [RMSSD]) showed relatively low error variance compared with the HRV parameters extracted from the normal interbeat interval signals. The Pearson correlation coefficient tests (P<.001) indicated that HR, RMSSD, average of normal heart beat intervals (AVNN), and percentage of successive normal beat-to-beat intervals that differ by more than 50 ms (pNN50) had high positive correlations with the baseline values; SD of normal beat-to-beat intervals (SDNN) and high frequency (HF) had moderate positive correlations, and low frequency (LF) and LF:HF ratio had low positive correlations. The HR, RMSSD, AVNN, and pNN50 had narrow 95% CIs; however, SDNN, LF, HF, and LF:HF ratio had relatively wider 95% CIs. In contrast, the average-per-night test showed that the HR, RMSSD, SDNN, AVNN, pNN50, LF, and HF had high positive relationships (P<.001), and the LF:HF ratio had a moderate positive relationship (P<.001). The average-per-night test also indicated considerably lower error variances than the 5-minute test for the parameters. Conclusions: The Oura Ring could accurately measure nocturnal HR and RMSSD in both the 5-minute and average-per-night tests. It provided acceptable nocturnal AVNN, pNN50, HF, and SDNN accuracy in the average-per-night test but not in the 5-minute test. In contrast, the LF and LF:HF ratio of the ring had high error rates in both tests.

2 November 2020 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
MMMilad Asgari Mehrabadi
Milad Asgari Mehrabadi
IAIman Azimi
Iman Azimi
Fatemeh SarhaddiFatemeh Sarhaddi
Fatemeh Sarhaddi
AAAnna Axelin
Anna Axelin
HNHannakaisa Niela-Vilén
Hannakaisa Niela-Vilén
ARAmir Rahmani
Amir Rahmani
Background: Assessment of sleep quality is essential to address poor sleep quality and understand changes. Owing to the advances in the Internet of Things and wearable technologies, sleep monitoring under free-living conditions has become feasible and practicable. Smart rings and smartwatches can be employed to perform mid- or long-term home-based sleep monitoring. However, the validity of such wearables should be investigated in terms of sleep parameters. Sleep validation studies are mostly limited to short-term laboratory tests; there is a need for a study to assess the sleep attributes of wearables in everyday settings, where users engage in their daily routines. Objective: This study aims to evaluate the sleep parameters of the Oura ring along with the Samsung Gear Sport watch in comparison with a medically approved actigraphy device in a midterm everyday setting, where users engage in their daily routines. Methods: We conducted home-based sleep monitoring in which the sleep parameters of 45 healthy individuals (23 women and 22 men) were tracked for 7 days. Total sleep time (TST), sleep efficiency (SE), and wake after sleep onset (WASO) of the ring and watch were assessed using paired t tests, Bland-Altman plots, and Pearson correlation. The parameters were also investigated considering the gender of the participants as a dependent variable. Results: We found significant correlations between the ring’s and actigraphy’s TST (r=0.86; P<.001), WASO (r=0.41; P<.001), and SE (r=0.47; P<.001). Comparing the watch with actigraphy showed a significant correlation in TST (r=0.59; P<.001). The mean differences in TST, WASO, and SE of the ring and actigraphy were within satisfactory ranges, although there were significant differences between the parameters (P<.001); TST and SE mean differences were also within satisfactory ranges for the watch, and the WASO was slightly higher than the range (31.27, SD 35.15). However, the mean differences of the parameters between the watch and actigraphy were considerably higher than those of the ring. The watch also showed a significant difference in TST (P<.001) between female and male groups. Conclusions: In a sample population of healthy adults, the sleep parameters of both the Oura ring and Samsung watch have acceptable mean differences and indicate significant correlations with actigraphy, but the ring outperforms the watch in terms of the nonstaging sleep parameters.

8 May 2018 in IEEE Journal of Translational Engineering in Health and Medicine
Verified
Journal Article
Open access
Geng YangGeng Yang
Geng Yang
JDJia Deng
Jia Deng
GPGaoyang Pang
Gaoyang Pang
HZHao Zhang
Hao Zhang
JLJiayi Li
Jiayi Li
HYHuayong Yang
Huayong Yang
Surface electromyography signal plays an important role in hand function recovery training. In this paper, an IoT-enabled stroke rehabilitation system was introduced which was based on a smart wearable armband (SWA), machine learning (ML) algorithms, and a 3-D printed dexterous robot hand. User comfort is one of the key issues which should be addressed for wearable devices. The SWA was developed by integrating a low-power and tiny-sized IoT sensing device with textile electrodes, which can measure, pre-process, and wirelessly transmit bio-potential signals. By evenly distributing surface electrodes over user's forearm, drawbacks of classification accuracy poor performance can be mitigated. A new method was put forward to find the optimal feature set. ML algorithms were leveraged to analyze and discriminate features of different hand movements, and their performances were appraised by classification complexity estimating algorithms and principal components analysis. According to the verification results, all nine gestures can be successfully identified with an average accuracy up to 96.20%. In addition, a 3-D printed five-finger robot hand was implemented for hand rehabilitation training purpose. Correspondingly, user's hand movement intentions were extracted and converted into a series of commands which were used to drive motors assembled inside the dexterous robot hand. As a result, the dexterous robot hand can mimic the user's gesture in a real-time manner, which shows the proposed system can be used as a training tool to facilitate rehabilitation process for the patients after stroke.

22 November 2017 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
Geng YangGeng Yang
Geng Yang
MJMingzhe Jiang
Mingzhe Jiang
WOWei Ouyang
Wei Ouyang
GJGuangchao Ji
Guangchao Ji
HXHaibo Xie
Haibo Xie
HTHannu Tenhunen
Hannu Tenhunen
Facial expressions are among behavioral signs of pain that can be employed as an entry point to develop an automatic human pain assessment tool. Such a tool can be an alternative to the self-report method and particularly serve patients who are unable to self-report like patients in the Intensive Care Unit and minors. In this paper, a wearable device with a bio-sensing facial mask is proposed to monitor pain intensity of a patient by utilizing facial surface electromyogram (sEMG). The wearable device works as a wireless sensor node and is integrated into an Internet of Things system for remote pain monitoring. In the sensor node, up to eight channels of sEMG can be each sampled at 1000 Hz, to cover its full frequency range, and transmitted to the cloud server via the gateway in real-time. In addition, both low energy consumption and wearing comfort are considered throughout the wearable device design for long-term monitoring. To remotely illustrate real-time pain data to caregivers, a mobile web application is developed for real-time streaming of high-volume sEMG data, digital signal processing, interpreting, and visualization. The cloud platform in the system act as a bridge between the sensor node and web browser, managing wireless communication between the server and the web application. In summary, this study proposes a scalable IoT system for real-time biopotential monitoring and a wearable solution for automatic pain assessment via facial expressions.

17 January 2019 in BMC Pregnancy and Childbirth
Verified
Journal Article
Open access
PDF file
KGKirsi Grym
Kirsi Grym
HNHannakaisa Niela-Vilén
Hannakaisa Niela-Vilén
EEEeva Ekholm
Eeva Ekholm
LHLotta Hamari
Lotta Hamari
IAIman Azimi
Iman Azimi
AAAnna Axelin
Anna Axelin
Smart wristbands enable the continuous monitoring of health parameters, for example, in maternity care. Understanding the feasibility and acceptability of these devices in an authentic context is essential. The aim of this study was to evaluate the feasibility of using a smart wristband to collect continuous activity, sleep and heart rate data from the beginning of the second trimester until one month postpartum. The feasibility of a smart wristband was tested prospectively through pregnancy in nulliparous women (n = 20). The outcomes measured were the wear time of the device and the participants’ experiences with the smart wristband. The data were collected from the wristbands, phone interviews, questionnaires, and electronic patient records. The quantitative data were analyzed with hierarchical linear mixed models for repeated measures, and qualitative data were analyzed using content analysis. Participants (n = 20) were recruited at a median of 12.9 weeks of gestation. They used the smart wristbands for an average of 182 days during the seven-month study period. The daily use of the devices was similar during the second (17.9 h, 95% CI 15.2 to 20.7) and third trimesters (16.7 h, 95% CI 13.8 to 19.5) but decreased during the postpartum period (14.4 h, 95% CI 11.4 to 17.4, p = 0.0079). Participants who could not wear smart wristbands at work used the device 300 min less per day than did those with no use limitations. Eight of the participants did not wear the devices or wore them only occasionally after giving birth. Nineteen participants reported that the smart wristband did not have any permanent effects on their behavior. Problems with charging and synchronizing the devices, perceiving the devices as uncomfortable, or viewing the data as unreliable, and the fear of scratching their babies with the devices were the main reasons for not using the smart wristbands. A smart wristband is a feasible tool for continuous monitoring during pregnancy. However, the daily use decreased after birth. The results of this study may support the planning of future studies and help with overcoming barriers related to the use of smart wristbands on pregnant women.