1 January 2020 in IEEE Transactions on Industrial Electronics
Pulse train (PT) control strategy for boost power factor correction (PFC) converter operating in continuous conduction mode (CCM) is proposed and studied in this paper. Average current mode (ACM) control is usually utilized for CCM boost PFC converter. ACM controlled PFC converter suffers from poor dynamic response, due to its voltage control loop has to be designed with low bandwidth to minimize the effect of low-frequency output voltage ripple on the current control loop. Different from ACM control, the voltage control loop and current control loop of PT controlled PFC converter are decoupled, thus the effect of low frequency output voltage ripple on the current control loop is eliminated. Besides, PT modulation is utilized in the proposed controller to regulate the inductor current to follow the current reference. Thus, both high power factor and fast dynamic response can be achieved. The operation principle of PT controlled CCM boost PFC converter is analyzed, and a 300W prototype is built to verify the analysis results. The experimental results show that power factor of PT controlled PFC converter is higher than 0.998 and the dynamic response is significantly improved.
21 June 2018 in IEEE Transactions on Industrial Electronics
In this paper, a digital-based pulse train (PT) control technique for boost power factor correction (PFC) converter operating in discontinuous conduction mode (DCM) is presented, which can achieve nearly unity power factor (PF) over universal input voltage range. Different from traditional digital control techniques which usually require complex arithmetic operations, digital-based PT control technique only needs simple operation. Besides, DCM boost PFC converter with digital PT control can operate at high switching frequency, which is less dependent on processing-speed of digital controller. Thus the proposed control strategy can be implemented with general purpose digital controllers, such as low speed and low cost microcontroller unit (MCU), for DCM boost PFC converter where the cost is a focus. The operation principle of digital PT controlled DCM boost PFC converter is analyzed. Experimental results are provided, which show that high PF and low input current THD can be maintained over universal input voltage range of 90~264V AC.
28 July 2022 in IEEE Transactions on Power Electronics
In high-load-current LLC dc–dc converter, synchronous rectification (SR) is usually used to reduce the secondary loss. As a lossless, low-cost, and small-volume SR control strategy, the drain–source voltage of SR switches sensing method is used widely in industrial applications. However, when the load current increases, the voltage ringing across SR switches during O stage is more and more severe and reaches zero eventually. When the voltage ringing reaches around zero in LLC converter, the voltage-sensing-method SR controller will generate the false driving signal, which makes SR switches turn on early and causes the converter works abnormally. This article presents the accurate analysis and design of the circuit parameters of LLC dc–dc converter to prevent the voltage ringing across the SR switches reaches around zero. The voltage ringing model is established, and the parameters design principle is given. By using the proposed design guideline, the voltage ringing across SR switches will always be higher than zero over the full load range, which eliminates the turn- on early issue or turn- on several times in one cycle issue. Therefore, this article can provide a design reference and guideline for the high-load-current and high-output-power LLC converter with voltage sensing SR control strategy. A 2.16 kW SR LLC dc–dc converter prototype is built according to the proposed design guideline, and the experimental results verify the correctness and effectiveness of the analysis.
28 January 2021 in IEEE Access
Constant duty cycle controlled discontinuous conduction mode (DCM) flyback power factor correction (PFC) converter has the advantage of high power factor (PF) and the disadvantage of low efficiency. While, constant on-time (COT) controlled critical conduction mode (CRM) flyback PFC converter has the exact opposite features, besides its switching frequency varies in a line cycle, and the variation range is very large, which complicates the electromagnetic interference (EMI) design. In order to obtain both benefits of these two control methods, an adaptive off-time (AOT) control technique for DCM flyback PFC converter is proposed in this paper. By utilizing the output voltage and the amplitude of line voltage to adjust the off-time of the main switch, the magnetizing current of transformer exactly operates in CRM when the rectified input voltage gets the peak. Thus, the root-mean-square (RMS) current of the main switch and the diode, as well as the conduction loss can be effectively reduced, and high efficiency can be obtained. The proposed control technique also can achieve theoretical unity PF over universal input voltage range of 90~264VAC. Moreover, its variation range of switching frequency is greatly reduced compared to that of COT control. A 60W prototype has been fabricated and tested in the laboratory and experimental results are presented to verify the effectiveness of the proposed method.
26 February 2025 in IEEE Transactions on Transportation Electrification
Traditionally, the energy feedback in synchronous rectifier (SR) LLC converter was once considered to only have the ability to reduce the voltage gain. In this article, a kind of special energy feedback caused by the novel operation modes of LLC resonant converter is proposed for improving voltage gain. Compared to the P, O, and N stages in conventional LLC converter, stage F is built by controlling the turn-on early time of the SR. By using the proposed operation modes, not only zero-voltage switching (ZVS) of both the primary-side and secondary-side switches is achieved, but the voltage gain of the LLC converter can be increased significantly with a narrow switching frequency range and a smaller magnetizing inductance circulating current. In addition, the proposed operation modes are simple and easy to be utilized in full bridge, half bridge, and so on; all kinds of LLC converters thus can form a new general control strategy of the SR LLC. Finally, a 100-W half-bridge SR LLC dc-dc converter prototype with a wide voltage-regulation range is implemented to validate the proposed operation modes and the theoretical analysis.