30 April 2021 in IEEE Transactions on Power Electronics
The on-board low-voltage dc-dc converter (LDC) in electric vehicles (EVs) is used to connect the high-voltage battery with the low-voltage auxiliary system. With the advancement of auxiliary equipment in EVs, the output current of the LDC can be hundreds of amperes, which will cause high-conduction loss and severe thermal concern. In this article, a high-efficiency high-power-density on-board LDC is presented. To reduce current stress and improve efficiency, three-phase interleaved LLC dc-dc converters are paralleled to provide 270 A load current. Synchronous rectifier is used to reduce secondary conduction loss. zero-voltage-switching (ZVS) turn-on of primary switches and ZCS turn-off of secondary switches are achieved, thus switching loss can be reduced significantly. Moreover, phase-shedding technology is used to improve light load efficiency. Switch-controlled capacitor (SCC) technology is used to achieve accurate load current sharing among the three phases, which protects the devices against high-current stress, reduces the conduction loss, and improves the reliability of the system. As SCC switches achieve ZVS turn-on and turn-off by its nature, the loss of the SCC circuit is of less concern with regard to the rated output power. In addition, GaN HEMTs are used in the primary side to improve the power density and eventually help achieving light weight. A 3.8-kW (14 V/270 A) LDC prototype is developed and tested. Experimental results show good current balancing among the three phases. A peak efficiency of 96.7% at 140 A load and a full load efficiency of 95.8% are achieved with 3 kW/L power density and 1.5 kg weight.
5 February 2018 in IEEE Transactions on Industrial Electronics
A single-stage soft-switching low-distortion bipolar pulsewidth modulation (BPWM) modulation high-frequency-link (HFL) dc-ac converter with clamping circuits is proposed in this paper. The converter consists of a primary side half bridge high-frequency inverter, a secondary side cycloconverter, and clamping circuits composed of a two-switch forward active clamping circuit and a passive clamping circuit. The clamping circuits recycle the energy in leakage inductances and output filter inductor during the dead time of the cycloconverter, clamp the voltage spike across bidirectional switches, and achieve soft switching of secondary side cycloconverter under BPWM modulation. Compared with unipolar PWM HFL dc-ac converter, BPWM HFL dc-ac converter has no duty cycle loss and narrow pulse in transformer primary, thus zero-crossing distortion is reduced. In this paper, soft switching and low zero-crossing distortion of the proposed dc-ac converter are analyzed. Experimental results of a 200 W prototype of the proposed dc-ac converter designed as audio amplifier are presented to verify the analysis results. Experimental results show that peak efficiency is 93.5% and ultralow output voltage total harmonic distortion +noise (THD + N) is lower than 0.2%.
30 December 2020 in IEEE Transactions on Power Electronics
In this letter, a soft switching transformerless dc-dc converter with Single Input Bipolar Symmetric Outputs (SIBSO) is proposed, which has positive and negative outputs with equal voltage amplitude and can be used in audio amplifier, bipolar symmetric auxiliary power supply application, etc., Based on the proposed bipolar symmetric outputs cell, the SIBSO dc-dc converter only requires two switches forming a half bridge circuit, and zero voltage switching (ZVS) of the two switches can be achieved over full load range. In addition, common ground of input and outputs is realized, which means the floating driver and isolated sensors are not required in the proposed dc-dc converter. The controller and drivers can be powered up by using input power supply through a simple step-down circuit, which not only reduces the cost, volume, but also the complexity of the converter. The operation modes and characteristic of the proposed SIBSO dc-dc converter are analyzed. Moreover, parameters design for ZVS operation is presented. Finally, a 60W 1MHz switching frequency prototype is built up by using GaN HEMTs. Experimental results show that bipolar symmetric outputs are obtained with common ground of input and output, peak efficiency of 95.8% and 154W/in3 power density are achieved.
30 June 2022 in IEEE Transactions on Power Electronics
In high-power medium-voltage applications, inductors usually have multiple windings on a single core, due to the high inductance value and high current stress. The multiple coils are electronically connected in either series or parallel, with considerations of windings loss and cost. However, the differences in parasitic capacitance of inductors using parallel and series connections are not discussed. Therefore, this article reveals that in comparison to parallel connections for windings, utilizing series connection for winding can significantly reduce the parasitic capacitance in multiwindings inductors without sacrificing the power density and adding manufacturing complexities. Physics-based models of parasitic capacitance in inductors with round-cable and copper-foil windings are developed for theoretical analysis. According to the theoretical analysis, the equivalent capacitance contributed by the stored electric field energy between two layers can be halved at least. The theoretical analysis is also verified by FEM simulations. Six prototyped inductors are experimentally compared to validate the theory.
28 July 2022 in IEEE Transactions on Power Electronics
In high-load-current LLC dc–dc converter, synchronous rectification (SR) is usually used to reduce the secondary loss. As a lossless, low-cost, and small-volume SR control strategy, the drain–source voltage of SR switches sensing method is used widely in industrial applications. However, when the load current increases, the voltage ringing across SR switches during O stage is more and more severe and reaches zero eventually. When the voltage ringing reaches around zero in LLC converter, the voltage-sensing-method SR controller will generate the false driving signal, which makes SR switches turn on early and causes the converter works abnormally. This article presents the accurate analysis and design of the circuit parameters of LLC dc–dc converter to prevent the voltage ringing across the SR switches reaches around zero. The voltage ringing model is established, and the parameters design principle is given. By using the proposed design guideline, the voltage ringing across SR switches will always be higher than zero over the full load range, which eliminates the turn- on early issue or turn- on several times in one cycle issue. Therefore, this article can provide a design reference and guideline for the high-load-current and high-output-power LLC converter with voltage sensing SR control strategy. A 2.16 kW SR LLC dc–dc converter prototype is built according to the proposed design guideline, and the experimental results verify the correctness and effectiveness of the analysis.
23 January 2023 in IEEE Transactions on Industrial Electronics
The time-domain analysis on single-stage LLC power factor correction (PFC) converter is performed in this article, which reveals that PON mode may occur around the peak point of instantaneous input power and cause instability issue. In order avoid PON mode, the power boundary between PO and PON mode is calculated. For the common design methods of LLC PFC converter with average mode control strategy, the power boundary requires to be higher than the instantaneous input power at its worst point. However, higher power boundary brings higher rms value of resonant current, and causes higher reactive power loss. Therefore, it is a wasteful designing methodology, as the other points of instantaneous input power do not need such high power boundary. In order to improve the efficiency, a power boundary control strategy is proposed in this article. By controlling the input current to make the instantaneous input power follow the power boundary, PON mode is eliminated. Consequently, the required power boundary is overall reduced, and the minimal rms current of resonant tank can be achieved. Furthermore, the optimal parameter design is also presented. A 90–240 VAC input and 250 W/48 V output experimental prototype has been built to verify the analysis results.