Ramon Santos Souza

Ramon Santos Souza

Auto-generated profile, based on publicly available information

Ramon Santos Souza

Graduate Program in Science, Innovation and Modeling in Materials (PROCIMM), Department of Engineering and Computing, State University of Santa Cruz (UESC), Ilhéus 45662-900, BA, Brazil

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 January 2025 in Buildings
Verified
Journal Article
Open access
PDF file
WJWanderson Santos de Jesus
Wanderson Santos de Jesus
SSSuânia Fabiele Moitinho da Silva
Suânia Fabiele Moitinho da Silva
TAThalles Murilo Santos de Almeida
Thalles Murilo Santos de Almeida
Marcelo Tramontin SouzaMarcelo Tramontin Souza
Marcelo Tramontin Souza
ELEduarda Silva Leal
Eduarda Silva Leal
JPJosé Renato de Castro Pessôa
José Renato de Castro Pessôa
Durability is crucial for reinforced concrete, directly influencing the service life of structures. The presence of aggressive agents, especially chloride ions, significantly impacts durability. This study investigates the differences between ASTM C1202 and IBRACON/NT Build 492 standards in concrete containing various types of cement designed for a characteristic compressive strength of 40 MPa. Forty-eight cylindrical samples were prepared using eight types of Portland cement, including those with blast furnace slag, filler, and pozzolanic materials. Chloride migration tests were performed according to the ASTM C1202/2022 and IBRACON/NT Build 492/1999 methodologies. At a 95% confidence level, the results indicated that concrete made with filler-containing cement (PCII F-SR and PC II F) showed the poorest chloride resistance, with charge passing values exceeding 4000 coulombs (ASTM C1202) and diffusion coefficients above 10 × 10−12 m2/s (IBRACON/NT Build 492). In contrast, concrete containing high slag cement (PC III-SR) and pozzolan cement (PC IV) demonstrated superior resistance to chloride penetration, with charge passing values below 1500 coulombs and diffusion coefficients under 5 × 10−12 m2/s. Notably, discrepancies in classification were observed, as PC II Z (fly-ash based) and PC II E-SR (slag-based) received different ratings under the two methods. ASTM C1202 was found to be more stringent than NT Build 492, highlighting significant variations in the classification criteria between these standards. Based on the findings, new interval values are proposed for classifying concrete regarding the risk of chloride ion penetration, particularly for the ASTM C1202 standard, in order to better align with performance-based durability criteria and improve classification accuracy.

26 February 2025 in Journal of Composites Science
Verified
Journal Article
Open access
PDF file
WJWanderson Santos de Jesus
Wanderson Santos de Jesus
TAThalles Murilo Santos de Almeida
Thalles Murilo Santos de Almeida
SSSuânia Fabiele Moitinho da Silva
Suânia Fabiele Moitinho da Silva
Marcelo Tramontin SouzaMarcelo Tramontin Souza
Marcelo Tramontin Souza
ELEduarda Silva Leal
Eduarda Silva Leal
JPJosé Renato de Castro Pessôa
José Renato de Castro Pessôa
Engineers commonly use the 28-day characteristic strength of concrete for project calculations, but this may not reflect the full-strength potential, especially in concretes with supplementary cementitious materials (SCMs). SCMs, known for their slow reactivity, often delay optimal strength beyond 28 days, requiring higher cement content to speed up early strength development, thus increasing production costs. This study examined the relationship between concrete age and mechanical strength across eight cement types, including tests for axial compression, water absorption, void index, and specific mass. The findings showed that pozzolan and slag cements gained significant long-term strength due to slow pozzolanic reactions. Conversely, limestone filler mixes had lower initial strength and slower progress, likely due to increased porosity from fine fillers. A correlation was found between higher pozzolan content and improved durability, including reduced water absorption and void index. Cost analysis indicated that optimizing cement mix designs for targeted strength levels could reduce production costs, especially for concretes with high SCM content. Using long-term characteristic strength rather than the traditional 28-day strength resulted in approximately 14% savings, particularly for slag- and pozzolan-based cements. The savings were less significant for other cement types, emphasizing the importance of adjusting mix designs based on both performance and financial considerations.

1 January 2025 in REM - International Engineering Journal
Verified
Journal Article
Open access
PDF file
TAThalles Murilo Santos de Almeida
Thalles Murilo Santos de Almeida
WJWanderson Santos de Jesus
Wanderson Santos de Jesus
Marcelo Tramontin SouzaMarcelo Tramontin Souza
Marcelo Tramontin Souza
FAFlávia Araujo Azevedo
Flávia Araujo Azevedo
SSSuânia Fabiele Moitinho da Silva
Suânia Fabiele Moitinho da Silva
JPJosé Renato de Castro Pessôa
José Renato de Castro Pessôa
The extraction of sand from riverbeds through dredging is a common practice in construction and has given rise to significant environmental repercussions. Sand removal contributes to heightened turbidity and alterations in watercourses, reshaping the original channels due to equipment utilization, and disrupting their flow. In response to these challenges, crushed stone dust emerges as a sustainable alternative material for partially or entirely replacing natural sand in concrete production. This study aimed to evaluate the mechanical properties and workability of concrete with a characteristic compressive strength of 25 MPa, employing total replacement (100% crushed stone dust) and partial replacement (50% crushed stone dust and 50% sand). The materials utilized encompassed crushed stone, natural sand, Portland cement CP II F - 32, crushed stone dust, and a superplasticizer additive. The results indicated no significant difference in compressive strength (P < 0.05), with values of 36.85 MPa and 30.31 MPa for total and partial replacement, respectively, comparable to the reference concrete (33.47 MPa). In terms of tensile strength by split tensile testing, concrete with total and partial replacement achieved 3.09 MPa and 3.23 MPa, respectively, while the reference mix recorded 3.31 MPa. Total replacement posed challenges to the workability of fresh concrete, necessitating a higher dosage of superplasticizer. In conclusion, crushed stone dust demonstrates its capacity to substitute natural sand, either entirely or partially, while upholding mechanical properties comparable to traditional concrete. However, careful consideration of the impact on concrete workability is essential when opting for total replacement of the fine aggregate.

1 January 2025 in Materials Research
Verified
Journal Article
Open access
RSRamon Santos Souza
Ramon Santos Souza
WJWanderson Santos de Jesus
Wanderson Santos de Jesus
TAThalles Murilo Santos de Almeida
Thalles Murilo Santos de Almeida
JAJoaquim Teixeira Assis
Joaquim Teixeira Assis
MAMarcelino José dos Anjos
Marcelino José dos Anjos
JPJosé Renato de Castro Pessôa
José Renato de Castro Pessôa
Chloride ions are the primary aggressive agents responsible for the corrosion of reinforced concrete structures and, consequently, the reduction of their service life, which entails high repair costs. These ions penetrate the concrete through its porous network and depassivate the steel reinforcement, even in small quantities. The adoption of specific binders modifies the cementitious matrix, potentially hindering the progression of these ions. As a chloride detection technique, X-ray fluorescence (XRF) can be employed, which, in addition to identifying the elements present in a sample, allows the creation of intensity distribution maps. Thus, this study aimed to evaluate how the XRF technique can contribute to understanding chloride penetration and to identify which cement types most effectively hinder their advancement. To accelerate chloride ion migration, two methods were employed: ASTM C1202 and NT Build 492. Eight different types of cement were analyzed, and the results indicated high resistance to chloride penetration in cements containing slag and pozzolan, while cements with filler exhibited lower resistance.