Mario Alberto Garcia Perez

Mario Alberto Garcia Perez

Auto-generated profile, based on publicly available information

Mario Alberto Garcia Perez

Universidad Nacional del Callao

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2025 in International Journal of Electrical and Computer Engineering (IJECE)
Verified
Journal Article
Open access
PDF file
JGJuan Grados
Juan Grados
SJSantiago Linder Rubiños Jimenez
Santiago Linder Rubiños Jimenez
RORojas Salazar Arcelia Olga
Rojas Salazar Arcelia Olga
ECEduardo Nelson Chavez
Eduardo Nelson Chavez
LJLinett Angélica Velasquez Jimenez
Linett Angélica Velasquez Jimenez
MPMario Alberto Garcia Perez
Mario Alberto Garcia Perez
Water quality assessment presents challenges, primarily the paucity of available data and ongoing system maintenance. This research develops an automated monitoring and control of water quality parameters in aquaponic systems with internet of thing (IoT) technology. Proper fish feeding management is important, which is why the fish were fed at 12:00, 16:00 and 07:00. The most significant relative error recorded during the validation of the DS18B20, PH-4502C, SEN0244, SEN0237-A, SEN0189 and DFR0300 sensors is 5.0%. The maximum standard deviation between the mentioned sensors was 1.96, and the highest coefficient of variation reached 7.24%. Before the installation of the aquaponic system, the specific growth rate (SGR) of fish was 4.89±0.17% and after implementing the automated aquaponics system, the SGR of fish increased to 6.21±0.24%. The feed conversion ratio values of the fish, both before and after the installation of the control system, were 1.98±0.14% and 1.53±0.09%, respectively. In addition, an improvement in plant growth was observed, evidenced by the difference in the values of height, number of leaves, leaf length, and weight of the plants before and after the installation of the control system, which was 7.74 cm, 5 leaves, 5.6 cm, and 41.6 g respectively.

1 January 2024 in Indonesian Journal of Electrical Engineering and Computer Science
Verified
Journal Article
Open access
PDF file
SJSantiago Linder Rubiños Jimenez
Santiago Linder Rubiños Jimenez
MPMario Alberto Garcia Perez
Mario Alberto Garcia Perez
ECEduardo Nelson Chavez
Eduardo Nelson Chavez
LJLinett Angélica Velasquez Jimenez
Linett Angélica Velasquez Jimenez
NCNiko Alain Alarcon Cueva
Niko Alain Alarcon Cueva
MCMauro Bernardo Sanchez Cabrera
Mauro Bernardo Sanchez Cabrera
Several patients who have overcome coronavirus disease (COVID-19) have been left with cardiovascular and pulmonary sequelae and most medical centers lack a remote monitoring system for each patient that notifies them of any complications during rehabilitation. The objective of this research was to implement a Wearable that monitors the patient's health and alerts in case of detecting any anomaly. For this reason, a Wearable was developed that displays the patient's heart rate, oxygen saturation level and body temperature on the Light Emitting Diode (LCD) and the application mobile, sending an alert and geolocation message if anomalies are detected in vital signs. The standard deviation of heart rate, temperature and oxygen saturation was obtained, which was 1.4930, 0.1558 and 0.4364 in the rest stage, respectively, and 6.3442, 0.2365 and 0.9186 in the physical activity stage respectively with a maximum duration of 42 hours and 52 minutes of battery, managing to send alert messages and store the information in the cloud, which allows to conclude that the Wearable can facilitate the management of the database and the location of the patient, that the measurement error increases with physical activity, and that battery life varies with the number of biosignal readings per hour.

16 December 2021 in Revista de Investigación de Física
Verified
Journal Article
Open access
PDF file
AAAbel Carmona Arteaga
Abel Carmona Arteaga
DSDouglas Donal Sarango-Julca
Douglas Donal Sarango-Julca
MPMario García Pérez
Mario García Pérez
Este trabajo se enfoca en el cálculo y validación de los parámetros usados para la generación de caudales de máximas avenidas a lo largo de 16 puntos de interés en el cauce principal del río Biabo. Debido a la insuficiente información de mediciones meteorológicas e hidrométricas dentro de la cuenca, se utilizó la información grillada de precipitación diaria de la base de datos PISCO v2.1 del SENAMHI, el modelo de curvas de duración frecuencia del estudio ILLA-SENAMHI-UNI, y el hidrograma unitario de Snyder, y los resultados obtenidos fueron calibrados en base a los registros de caudales máximos de la estación hidrométrica Requena-Biabo. Así, por ejemplo, para la cuenca de la estación Requena-Biabo, la comparación entre los caudales de máximas avenidas generados con los caudales registrados para diferentes tiempos de retorno, el error obtenido fluctúa entre ±5%.