1 September 2023 in IEEE Transactions on Instrumentation and Measurement
The early displacement monitoring of excavation pits is currently a primary method to prevent pit collapse accidents. However, conventional pit displacement monitoring mainly relies on regular manual measurement or automated professional instrument measurement, which results in high cost, complex operation and deployment, non-real-time measurement, and non-intuitive data collection. Consequently, this paper proposes a method for the visual measurement of three-dimension (3D) displacement of pits based on a two-stage Perspective-n-Point (PNP) algorithm. Initially, markers are installed on the reference points with known 3D spatial coordinates and on each displacement measurement point of the excavation pit. All markers are scanned sequentially by panning the camera and zooming the lens, ensuring at least two adjacent markers enter the frame and are captured in each shot. Secondly, the improved Histogram of Oriented Gradients (HOG) combined with Support Vector Machine (SVM) rapid algorithm is utilized to perform quick detection and coarse positioning of each marker in the aforementioned photos. Thirdly, the sub-pixel algorithm and image morphology are combined. Based on the coarse positioning, the pixel coordinate values of the markers in the images are calculated. Lastly, the two-stage PNP algorithm is applied in a cyclical fashion: by using the known 3D spatial coordinates and its pixel coordinates of the previous marker to solve for the current camera’s 3D spatial coordinates and pose, the 3D spatial coordinates of the next marker can be derived using the current camera’s 3D spatial coordinates and pose and the pixel coordinates of the next marker. This cycle continues until the 3D spatial coordinates of all markers are fully resolved, thereby achieving accurate measurement of the 3D displacement of the pit. Experimental results show that the accuracy of the proposed method is nearly as high as the measurement accuracy of manual total stations, meeting the requirements for daily 3D displacement measurement of excavation pits. Meanwhile, this method offers the advantages of low cost, simple deployment and operation, and a high degree of automation.
26 September 2020 in Journal of Biomedical Optics
Since Heimstaedt and Lehmann developed the first fluorescence microscope in the early 20th century,1,2 it has become a critical tool for biological research. The use of fluorescent probes has allowed scientists and physicians to increase contrast and signal from a region of interest, allowing for the study of biological systems that could not previously be imaged. One of the most common uses for fluorescence is in the diagnosis, planning, and treatment of cancer. For example, fluorescence imaging has been used for guiding the resection of brain tumors. Gliolan® [5-aminolevulinic acid hydrochloride (5-ALA)] is an FDA-approved imaging agent used for fluorescence-guided surgery of malignant gliomas (e.g., glioblastoma multiforme, GBM). 5-ALA is a hemoglobin precursor, with protoporphyrin IX (PpIX) being a fluorescent intermediary molecule.3,4 Changes in various metabolic pathways, such as the upregulation of coproporphyrinogen and downregulation of ferrochelatase, lead to the preferential accumulation of PpIX in glioma cells over healthy brain tissues.5 By exciting the PpIX in tumor tissues with light at wavelengths in the range of 375-nm to 420-nm during surgery, tumor margins are highlighted for better detection and resection,6 increasing patient mean overall survival by an average of 3 months when compared with white light techniques.7