Mabrouk Defdaf

Mabrouk Defdaf

Auto-generated profile, based on publicly available information

Mabrouk Defdaf

Electrical Engineering Laboratory, Faculty of Technology, University of Msila, Msila, Algeria

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 February 2021 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Closed access
PDF file
MDMabrouk Defdaf
Mabrouk Defdaf
FBFouad Berrabah
Fouad Berrabah
ACAli Chebabhi
Ali Chebabhi
BCBilal Djamal Eddine Cherif
Bilal Djamal Eddine Cherif

23 January 2025 in IEEE Access
Verified
Journal Article
Open access
ACALI CHEBABHI
ALI CHEBABHI
DMDefdaf Mabrouk
Defdaf Mabrouk
Syphax IHAMMOUCHENSyphax IHAMMOUCHEN
Syphax IHAMMOUCHEN
Nicu BizonNicu Bizon
Nicu Bizon
Habib BenbouhenniHabib Benbouhenni
Habib Benbouhenni
Mohamed Fouad BENKHORISMohamed Fouad BENKHORIS
Mohamed Fouad BENKHORIS
The integration of photovoltaic (PV) systems with the grid connected four-leg voltage source inverters (4LVSI) offers more efficient power conversion and distribution. However, the complexity of these higher-order systems presents significant control challenges due to the sensitive nature of both DC bus voltage and 4LVSI output currents, which introduce complex dynamic interactions within the 4LVSI control system and limit its overall control performance, particularly under system uncertainties and disturbances such as variations in irradiance, PV cell temperature, and grid voltage. To address these challenges, an enhanced active disturbance rejection control (EADRC) scheme based on a super-twisting sliding mode observer (STSMO) is designed for the outer DC bus voltage control loop. The STSMO is incorporated in the ADRC method for its fast uncertainties and external disturbances estimations, high resilience against uncertainties, and good immunity to measurement noise. The proposed STSMO-based ADRC approach effectively estimates and compensates for system uncertainties and external disturbances, thereby enhancing DC bus voltage dynamics and stability, improving resilience against uncertainties, increasing immunity to measurement noise, ensuring better steady-state accuracy of the DC bus voltage, and increasing system reliability while reducing cost and size. The effectiveness and superiority of the proposed control method for the PV grid-connected 4LVSI system are validated through both simulation and real-time studies using the OPAL-RT simulator. The results demonstrate robust performance under parameter uncertainties and disturbances, including variations in irradiance, PV cell temperature, DC bus capacitor value, and grid voltage sags.

1 January 2024 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Open access
MDMabrouk Defdaf
Mabrouk Defdaf
DZDjamel Ziane
Djamel Ziane
ACALI CHEBABHI
ALI CHEBABHI
SBSaid Barkat
Said Barkat
Mohamed Fouad BENKHORISMohamed Fouad BENKHORIS
Mohamed Fouad BENKHORIS
AKAbdelhalim KESSAL
Abdelhalim KESSAL
In practical three‐phase PWM rectifiers, external disturbances, such as changes in load and grid voltage, and internal disturbances, such as DC capacitor uncertainty, have caused major problems, including DC‐link voltage fluctuations, harmonic distortion, and power factor degradation. They can also cause problems with power balance, stability, system dynamics, reduced efficiency, and increased stress. This paper proposes an enhanced linear state observer (ELSO) with a PLL‐less voltage‐oriented control (PLL‐less VOC) method for a three‐phase PWM rectifier in the synchronous coordinate frame (dq coordinate), aiming to simultaneously improve the DC‐link voltage dynamics, disturbance rejection ability, and the grid current control loop’s transient response. The ELSO is suggested instead of the load current sensor not only to estimate the disturbance but also to estimate the overall switching losses of the PWM rectifier, resulting in good DC‐link voltage disturbance rejection and transient fluctuation suppression, high robustness against DC capacitance change, low size and cost, and high reliability. Furthermore, contrary to the traditional VOC method, where the PLL and Park transforms are important parts for controlling the rectifier in the dq coordinate, the PLL‐less VOC method can control the grid currents directly in the dq coordinate without needing PLL and Park transforms, which can offer a fast transient response and low computational burden. The frequency domain analysis of the ELSO is used to identify its gains and enhance its stability and disturbance rejection capability. Finally, hardware‐in‐the‐loop (HIL) simulation using the OPAL‐RT 4510 real‐time simulator is also given to confirm the superiority and efficacy of the suggested control method.

20 December 2021 in Metrology and Measurement Systems
Verified
Journal Article
Closed access
PDF file
BCBilal Djamal Eddine Cherif
Bilal Djamal Eddine Cherif
SSSara Seninete
Sara Seninete
MDMabrouk Defdaf
Mabrouk Defdaf

3 April 2023 in Periodica Polytechnica Electrical Engineering and Computer Science
Verified
Journal Article
Open access
PDF file
AAAla Addin Mohammed Al-Dwa
Ala Addin Mohammed Al-Dwa
ACALI CHEBABHI
ALI CHEBABHI
MDMabrouk Defdaf
Mabrouk Defdaf
AGAnwar Guessabi
Anwar Guessabi
The synchronization method’s ability is one of the fundamental guarantees for the stability and accuracy of injected current control for grid-connected converter-based distribution resources. These synchronization methods, such as phase locked loop (PLL), are generally based on Park transformation and grid voltage regulation, which may affect an unstable phenomenon under distortion and unbalanced grid voltage conditions and result in more computational complexity. In this present paper, analogous to the traditional voltage-oriented control strategy (VOC) in the synchronous rotating frame (dq0-frame) based on PLL and Parks transformation, an improved voltage-oriented control strategy (IVOC) without synchronization methods and Parks transformation is proposed for grid-connected four-leg inverters (GC-FLVSI) to achieve accurate current control with high-quality performance in the dq0-frame. This proposed strategy is not only used for controlling the GC-FLVSI but also to provide the module of GC-FLVSI in the dq0-frame based on the instantaneous active and reactive powers theory (DPC). The proposed IVOC strategy has the same properties and identical performance as the traditional VOC when the grid phase angle is correctly detected by any synchronization method, with the advantages of both traditional DPC and VOC at the same time. In order to validate the superiority and excellent dynamic and steady-state performances of the proposed IVOC strategy in comparison with the traditional VOC strategy, some simulation scenarios using MATLAB/Simulink under different operations and grid conditions have been performed and presented.