The integration of photovoltaic (PV) systems with the grid connected four-leg voltage source inverters (4LVSI) offers more efficient power conversion and distribution. However, the complexity of these higher-order systems presents significant control challenges due to the sensitive nature of both DC bus voltage and 4LVSI output currents, which introduce complex dynamic interactions within the 4LVSI control system and limit its overall control performance, particularly under system uncertainties and disturbances such as variations in irradiance, PV cell temperature, and grid voltage. To address these challenges, an enhanced active disturbance rejection control (EADRC) scheme based on a super-twisting sliding mode observer (STSMO) is designed for the outer DC bus voltage control loop. The STSMO is incorporated in the ADRC method for its fast uncertainties and external disturbances estimations, high resilience against uncertainties, and good immunity to measurement noise. The proposed STSMO-based ADRC approach effectively estimates and compensates for system uncertainties and external disturbances, thereby enhancing DC bus voltage dynamics and stability, improving resilience against uncertainties, increasing immunity to measurement noise, ensuring better steady-state accuracy of the DC bus voltage, and increasing system reliability while reducing cost and size. The effectiveness and superiority of the proposed control method for the PV grid-connected 4LVSI system are validated through both simulation and real-time studies using the OPAL-RT simulator. The results demonstrate robust performance under parameter uncertainties and disturbances, including variations in irradiance, PV cell temperature, DC bus capacitor value, and grid voltage sags.

19 May 2025 in IEEE Access
Verified
Journal Article
Open access
MOMohammed Said Ouahabi
Mohammed Said Ouahabi
ABAbdelhafid Benyounes
Abdelhafid Benyounes
SBSaid Barkat
Said Barkat
Syphax IHAMMOUCHENSyphax IHAMMOUCHEN
Syphax IHAMMOUCHEN
TRtoufik rekioua
toufik rekioua
AAAmel Alharbi
Amel Alharbi
DC Microgrids are rapidly developing, driven by the increasing integration of renewable sources and dynamic loads. Their growing adoption in critical applications raises the need for operational safety and reliability, particularly under fault conditions. This paper presents a sensor fault-tolerant control (FTC) for DC-DC power converters in DC Microgrids designed to maintain resilient and reliable operation. The proposed FTC leverages a single Switching Unknown Input Observer (SW-UIO) at the bottom control level to estimate arbitrary sensor faults with a high accuracy (0.3% fault estimation error), allowing a real-time identification and precise control reconfiguration to accommodate sensor faults with minimal computational burden. The approach is validated under diverse conditions, including time-varying loads, complete sensor failure, noise abnormality, and simultaneous faults/failure, achieving a consistent fault accommodation of 1μs from fault occurrence to compensation. Real-time simulation has been performed in the OPAL-RT environment to assess the efficacy and superiority of the proposed sensor fault tolerant strategy in comparison to reference FTC strategies.

27 January 2026 in Journal of Energy Storage
Verified
Journal Article
Open access
Syphax IHAMMOUCHENSyphax IHAMMOUCHEN
Syphax IHAMMOUCHEN
ACAli Chebabhi
Ali Chebabhi
DZDjamel Ziane
Djamel Ziane
HGHoussam Eddine Ghadbane
Houssam Eddine Ghadbane
TRToufik Rekioua
Toufik Rekioua
MBMohamed Fouad Benkhoris
Mohamed Fouad Benkhoris

24 April 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MOMohammed Said Ouahabi
Mohammed Said Ouahabi
SBSaid Barkat
Said Barkat
ABAbdelhafid Benyounes
Abdelhafid Benyounes
TRToufik Rekioua
Toufik Rekioua
Syphax IHAMMOUCHENSyphax IHAMMOUCHEN
Syphax IHAMMOUCHEN
MAMohammed M. Alammar
Mohammed M. Alammar
This paper introduces a decentralized active fault tolerant control technique for actuator faults in a DC microgrid with load variations and source perturbations without requiring communication between distributed generators or load current measurement. The proposed control technique consists of two sections, each designed separately. One section aims to maintain the system’s stability and desired performance; the other section compensates for the actuator fault through fault reconstruction. To achieve this, a decentralized unknown input proportional-integral observer (UI-PIO) estimates the fault accuracy regardless of the load variations. The proposed linear quadratic regulator (LQR)-based UI-PIO strategy optimizes the trade-off between control performance and energy consumption, ensuring efficient operation under normal conditions and minimizing disruptions during fault states while robust to load variation. The stability and robustness of the closed-loop system under load variations are ensured through Lyapunov’s conditions, solved by the linear matrix inequality technique. The proposed decentralized LQR-UI-PIO circumvents the limitations of load variations, source perturbations, and actuator fault by allowing local controllers within the MG to independently compute control actions based on locally available information and a shared global objective. Finally, the hardware-in-the-loop setup is implemented to evaluate and validate the efficiency of the proposed decentralized fault-tolerant technique. The obtained results highlight the effectiveness and efficiency of the proposed approach in detecting and reconstructing faults, maintaining stability, and improving performance, which makes this approach of interest in other industrial applications.

19 July 2024 in IEEE Access
Verified
Journal Article
Open access
AAAla Addin Mohammed Al-Dwa
Ala Addin Mohammed Al-Dwa
ACALI CHEBABHI
ALI CHEBABHI
DZDjamel Ziane
Djamel Ziane
SBSaid Barkat
Said Barkat
Syphax IHAMMOUCHENSyphax IHAMMOUCHEN
Syphax IHAMMOUCHEN
AAAyman Alhejji
Ayman Alhejji
Due to its good reliability, high modularity, zero-sequence current (ZSC) path, and lower size and cost, the parallel four-leg source voltage inverter’s topology is a perfect choice for many power applications, including renewable power generation-based stand-alone power-supply systems (SAPSSs). However, the major concern associated with this topology is the presence of a zero-sequence circulating current (ZSCC) that circulates between the phase legs of these inverters when the inverters operate under unbalanced current sharing or unbalanced output-filter parameters, which leads to multiple consequences, including output current distortion, power losses, and system stability degradation, as well as impacting the efficiency, reliability, and operational lifespan of the system. The ZSCC model demonstrates that the ZSCC amplitude is linked to the filter inductance and difference between zero-sequence duty ratios or zero-sequence voltages (ZSVs). Considering these facts, we propose a new modified three-dimensional space vector pulse width modulation (3DSVPWM) methodology to suppress ZSCC and its effects on the current quality, efficiency, reliability, and operational lifespan of the parallel system. The suggested strategy aims to eliminate the difference between ZSVs by adjusting the zero-vector duty ratios in each switching period. This adjustment keeps the ZSCC constant at zero with minimal oscillations and switching losses, thereby improving the output current quality, particularly in mitigating the $3^{\mathrm {rd}}$ harmonic and its multiples, and enhancing the system’s efficiency, reliability, and operational lifespan. The proposed method offers the advantages of being suitable for suppressing both the ZSCC and ZSC and not impacting the control purposes or the system’s output quality. The efficiency and performance of the designed method are validated through various Hardware-in-the-loop (HIL) tests under different conditions using the OPAL-RT-OP5700 real-time simulator.

8 October 2025 in IEEE Access
Verified
Journal Article
Open access
ACALI CHEBABHI
ALI CHEBABHI
BSBarkat Said
Barkat Said
DNDebdouche Naamane
Debdouche Naamane
Syphax IHAMMOUCHENSyphax IHAMMOUCHEN
Syphax IHAMMOUCHEN
Mohamed Fouad BENKHORISMohamed Fouad BENKHORIS
Mohamed Fouad BENKHORIS
VBVojtěch Blažek
Vojtěch Blažek
This paper presents an enhanced control strategy for a three-phase four-wire four-leg rectifier (3P4W4LR), aimed at improving dynamic and steady-state performances, disturbance rejection, robustness, and implementation efficiency. A nonlinear varying-gain observer (NVGO) integrated with a simple PI controller is proposed for the outer loop to regulate the DC-link voltage under different internal and external disturbances. Unlike traditional disturbance observers, which are highly sensitive to measurement noise and compromise transient response when gains are reduced, the proposed NVGO employs a variable-gain mechanism. High gain value is used during transients to ensure rapid disturbance estimation and rejection, while low gain value during steady-state minimizes noise sensitivity and estimation error. This results in superior disturbance rejection, improved dynamic response, reduced DC link voltage steady-state error, enhanced noise immunity, increased reliability, and reduced system size and cost. For the inner loop, a Grid-Voltage-Modulated Direct Power Control method based on super-twisting sliding mode control is introduced. Operating directly in the synchronous reference frame without relying on phase-locked loop or Park transformations, this approach simplifies implementation while delivering faster transient response, improved steady-state accuracy, and greater resilience to grid current system uncertainties and disturbances. To ensure robust performance, the closed-loop regional stability of the proposed NVGO with PI controller is rigorously analyzed using a piecewise quadratic Lyapunov function. The effectiveness and superiority of the proposed method are validated through both simulations and real-time hardware-in-the-loop testing. Extensive testing under dynamic load conditions, different grid voltage conditions, and DC-link capacitance uncertainty demonstrates the controller’s robust performance and practical viability.