Mingyu Sun

Mingyu Sun

Auto-generated profile, based on publicly available information

Mingyu Sun

School of EEE, The University of Manchester, Manchester United Kingdom of Great Britain and Northern Ireland m13 9pl

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 February 2021 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
MSMingyu Sun
Mingyu Sun
GLGaoyuan Liu
Gaoyuan Liu
MPMarjan Popov
Marjan Popov
VTVladimir Terzija
Vladimir Terzija
SASadegh Azizi
Sadegh Azizi
The conventional Under Frequency Load Shedding (UFLS) scheme could result in unacceptably low frequency nadirs or overshedding in power systems with volatile inertia. This paper proposes a novel UFLS scheme for modern power systems whose inertia may vary in a wide range due to high penetration of renewable energy sources (RESs). The proposed scheme estimates the rate of change of frequency (RoCoF) of the center of inertia (CoI), and consequently, the loss of generation (LoG) size, using local frequency measurements only. An innovative inflection point detector technique is presented to remove the effect of local frequency oscillations. This enables fast and accurate LoG size calculation, thereby more effective load shedding. The proposed UFLS scheme also accounts for the effect of the inertia change resulting from LoG events. The performance of the proposed scheme is validated by conducting extensive dynamic simulations on the IEEE 39-bus test system using Real Time Digital Simulator (RTDS). Simulation results confirm that the proposed UFLS scheme outperforms the conventional UFLS scheme in terms of both arresting frequency deviations and the amount of load shed.

7 August 2020 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
SASadegh Azizi
Sadegh Azizi
MSMingyu Sun
Mingyu Sun
GLGaoyuan Liu
Gaoyuan Liu
VTVladimir Terzija
Vladimir Terzija
This letter proposes a novel effective technique for estimating the rate of change of frequency (RoCoF) of the center of inertia (CoI) in power systems. To offer a holistic picture of the system's frequency response, the proposed technique requires local frequency at the point of measurement, only. This enables the local estimation of active power deficit following a loss of generation (LoG) event, thus facilitating fast and effective remedial action. The extensive number of simulations conducted verify the effectiveness and applicability of the proposed technique.

3 January 2020 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
QHQiteng Hong
Qiteng Hong
Mazaher KarimiMazaher Karimi
Mazaher Karimi
MSMingyu Sun
Mingyu Sun
SNSean Norris
Sean Norris
OBOleg Bagleybter
Oleg Bagleybter
CBCampbell Booth
Campbell Booth
This paper presents the design and validation of a Wide Area Monitoring and Control (WAMC) system for Fast Frequency Response (FFR) to address the challenges associated with reduced and non-uniformly distributed inertia in power systems. The WAMC system, designed for the power system in Great Britain, is termed “Enhanced Frequency Control Capability (EFCC)”. It uses real time measurements from Phasor Measurement Units (PMUs) to monitor the system state in order to rapidly detect frequency disturbances and evaluate the magnitude of power imbalances. The impact of the disturbances on different parts of the network is considered to subsequently allocate the required response for different regions of the network, all within less than one second from the initiating event. The capabilities and characteristics of different resources (e.g. wind, energy storage, demand, etc.) are also evaluated and taken into account to achieve a suitable, optimized and coordinated response. Case studies using highly realistic hardware-in-the-loop setups are presented and these demonstrate that the proposed system is capable of detecting frequency events and deploying appropriate and coordinated responses in a timely fashion even with degraded communication conditions, thereby effectively enhancing the frequency control in future low-inertia systems and permitting higher penetrations of low-carbon and low-inertia energy sources.

3 December 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Open access
SASadegh Azizi
Sadegh Azizi
MSMingyu Sun
Mingyu Sun
GLGaoyuan Liu
Gaoyuan Liu
MPMarjan Popov
Marjan Popov
VTVladimir Terzija
Vladimir Terzija
Short-circuit faults close to either end of a transmission line, are normally cleared instantaneously by the distance relay at that end and after hundreds of milliseconds, i.e., in Zone 2 operating time, by the relay at the opposite end of the line. This sequential tripping can be accelerated on condition that a reliable communication link is available for signaling between the two line ends. This paper proposes a novel non-communication method providing high-speed distance relaying over the entire length of the protected transmission line. The inputs to the method are the protected line parameters and local voltage and current signals measured by the relay, similar to those to conventional distance relays. The proposed method accomplishes Accelerated Sequential Tripping (AST) within a couple of cycles after the opening of the remote-end circuit breaker (ORCB) of the line. To achieve this, an accurate closed-form solution is derived for the fault distance in terms of post-ORCB voltage and current phasors. For the detection of the ORCB instant, a set of proper indices are proposed. This is to verify the fault distance calculated by the relay, before issuing a trip command. The proposed method is successfully validated by conducting more than 20000 hardware-in-the-loop (HIL) tests, and also using real-life data.

21 January 2013 in Journal of Software
Verified
Journal Article
Closed access
WLWenhui Li
Wenhui Li
YLYifeng Lin
Yifeng Lin
BFBo Fu
Bo Fu
MSMingyu Sun
Mingyu Sun
WWWenting Wu
Wenting Wu
Accurate and efficient human detection has become an important area for research in computer vision. In order to solve problems in the past human detection algorithms such as features with fixed sizes, fixed positions and fixed number, the human detection based on united Hogs algorithm was proposed. This algorithm can dynamically generate the features closer to human body contours. Basically maintaining the detection speed, the detection accuracy was improved by our algorithm. We demonstrate that comparing with human detection algorithm using haar, traditional hogs and a hog with variable-size blocks, our algorithm is better in both of detection rate and false positive rate. © 2013 ACADEMY PUBLISHER.