15 August 2019 in IEEE Transactions on Power Delivery
Noninvasive contactless methods for electric power line monitoring based on magnetic field measurement have become an interesting topic for researchers and the electric power industry since introduction of the Smart Grid concept. By measuring and analyzing magnetic field originating from currents in power line conductors, it is possible to detect faults in the network. In medium voltage distribution networks, where a variety of different pole geometries are present, different criteria for fault detection have to be employed for each geometry, which complicates detection and influences accuracy. This paper proposes a novel approach for fault detection in medium voltage distribution networks which is based on processing of signals measured by low cost contactless magnetic field sensors. In order to create a generalized method for fault detection, a sequence of mathematical transformations of the measured magnetic field components is applied. A novel geometric transformation which eliminates influence of pole geometry is introduced, providing signals from which steady-state symmetrical components of the rotating magnetic field are computed. Those components are used as general fault detection criteria. The proposed approach is confirmed to be applicable for different fault types by a set of experiments on three-phase overhead power line model scaled to laboratory conditions.
10 January 2022 in IJEEC - International Journal of Electrical Engineering and Computing
Monitoring and supervision of overhead power lines have become essential actions in Electrical Power Systems since the introduction of the Smart Grid concept. In order to monitor overhead power lines, simple non-invasive devices are mounted on support poles, which detect line abnormalities and faults by measuring magnetic field originating from power line conductors. Measured signals are also used to determine various electrical and non-electrical line parameters. In this paper a new approximate model for magnetic flux density vector components of the overhead power lines suitable for real-time conductor sag estimation is presented. In the proposed model, catenary-shaped power line conductors are approximated with tilted straight line conductors, and the approximate model is calibrated by tuning model coefficients to match flux density vector components as in the case of real catenary-shaped conductors. The accuracy of the proposed model is verified by measurements on three-phase overhead power line model scaled to laboratory conditions. As a conclusion, an adaptive method for possible practical implementation based on the approximate model is considered.