Predrag Mrsic

Predrag Mrsic

Auto-generated profile, based on publicly available information

Predrag Mrsic

Faculty of Electrical Engineering, University of Banja Luka, Banja Luka, Bosnia and Herzegovina

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2022 in Energy
Verified
Journal Article
Closed access
Čedomir ZeljkovićČedomir Zeljković
Čedomir Zeljković
PMPredrag Mršić
Predrag Mršić
BEBojan Erceg
Bojan Erceg
ĐLĐorđe Lekić
Đorđe Lekić
NKNemanja Kitić
Nemanja Kitić
PMPetar Matić
Petar Matić

15 August 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
DLDorde M. Lekic
Dorde M. Lekic
PMPredrag D. Mrsic
Predrag D. Mrsic
BEBojan B. Erceg
Bojan B. Erceg
Čedomir ZeljkovićČedomir Zeljković
Čedomir Zeljković
NKNemanja S. Kitic
Nemanja S. Kitic
PMPetar R. Matic
Petar R. Matic
Noninvasive contactless methods for electric power line monitoring based on magnetic field measurement have become an interesting topic for researchers and the electric power industry since introduction of the Smart Grid concept. By measuring and analyzing magnetic field originating from currents in power line conductors, it is possible to detect faults in the network. In medium voltage distribution networks, where a variety of different pole geometries are present, different criteria for fault detection have to be employed for each geometry, which complicates detection and influences accuracy. This paper proposes a novel approach for fault detection in medium voltage distribution networks which is based on processing of signals measured by low cost contactless magnetic field sensors. In order to create a generalized method for fault detection, a sequence of mathematical transformations of the measured magnetic field components is applied. A novel geometric transformation which eliminates influence of pole geometry is introduced, providing signals from which steady-state symmetrical components of the rotating magnetic field are computed. Those components are used as general fault detection criteria. The proposed approach is confirmed to be applicable for different fault types by a set of experiments on three-phase overhead power line model scaled to laboratory conditions.

1 November 2018
Verified
Conference Paper
Closed access
PMPredrag Mrsic
Predrag Mrsic
Čedomir ZeljkovićČedomir Zeljković
Čedomir Zeljković
DLDorde Lekic
Dorde Lekic
BEBojan Erceg
Bojan Erceg
PMPetar Matic
Petar Matic
PBPrzemyslaw Balcerek
Przemyslaw Balcerek
In this paper a methodology for determining proper number and positions of fault passage indicators (FPIs) in medium voltage distribution networks with installed fault locators (FLs) is proposed and discussed. The main goal is to achieve the techno-economic balance, by obtaining maximum improvement of the reliability indices while using the minimum number of FPIs. The method is verified by Monte Carlo simulation on a real combined urban/rural distribution network in Bosnia and Herzegovina. The purpose of the simulation tests is to assess performance of the proposed methodology, as well as to discuss the results and propose potential actions required to improve their reliability for several possible scenarios: the use of FLs only, the use of FPIs only and the combined use of FLs and FPIs.


1 January 2016
Verified
Conference Paper
Closed access
DLD. Lekic
D. Lekic
PMP. Mršic
P. Mršic
BEB. Erceg
B. Erceg
Čedomir ZeljkovićČedomir Zeljković
Čedomir Zeljković

1 October 2017
Verified
Conference Paper
Closed access
BBBranko Blanusa
Branko Blanusa
BKBojan Knezevic
Bojan Knezevic
BEBojan Erceg
Bojan Erceg
ELEorde Lekic
Eorde Lekic
PMPredrag Mrsic
Predrag Mrsic
ÐLðorđe Lekić
ðorđe Lekić
In this paper some of the problems related to electrical drives in modern elevators are presented. These are the modeling of jerk and the definition of the motion trajectory, power savings, efficiency optimization and possibilities for energy storage in generator mode, and application of suitable converters and control techniques for the implementation in elevator drives. Suggested solutions are tested through computer simulations and experimentally on the prototype of elevator drive.