Noninvasive contactless methods for electric power line monitoring based on magnetic field measurement have become an interesting topic for researchers and the electric power industry since introduction of the Smart Grid concept. By measuring and analyzing magnetic field originating from currents in power line conductors, it is possible to detect faults in the network. In medium voltage distribution networks, where a variety of different pole geometries are present, different criteria for fault detection have to be employed for each geometry, which complicates detection and influences accuracy. This paper proposes a novel approach for fault detection in medium voltage distribution networks which is based on processing of signals measured by low cost contactless magnetic field sensors. In order to create a generalized method for fault detection, a sequence of mathematical transformations of the measured magnetic field components is applied. A novel geometric transformation which eliminates influence of pole geometry is introduced, providing signals from which steady-state symmetrical components of the rotating magnetic field are computed. Those components are used as general fault detection criteria. The proposed approach is confirmed to be applicable for different fault types by a set of experiments on three-phase overhead power line model scaled to laboratory conditions.
In this paper a methodology for determining proper number and positions of fault passage indicators (FPIs) in medium voltage distribution networks with installed fault locators (FLs) is proposed and discussed. The main goal is to achieve the techno-economic balance, by obtaining maximum improvement of the reliability indices while using the minimum number of FPIs. The method is verified by Monte Carlo simulation on a real combined urban/rural distribution network in Bosnia and Herzegovina. The purpose of the simulation tests is to assess performance of the proposed methodology, as well as to discuss the results and propose potential actions required to improve their reliability for several possible scenarios: the use of FLs only, the use of FPIs only and the combined use of FLs and FPIs.
In this paper some of the problems related to electrical drives in modern elevators are presented. These are the modeling of jerk and the definition of the motion trajectory, power savings, efficiency optimization and possibilities for energy storage in generator mode, and application of suitable converters and control techniques for the implementation in elevator drives. Suggested solutions are tested through computer simulations and experimentally on the prototype of elevator drive.