16 April 2013 in IEEE Transactions on Industrial Electronics
In numerous motor drive applications, high rotor speed is the key factor for system cost, performance, and overall energy efficiency. As a result of energy crises and global market competition, the specified rotor speed and fundamental frequency of the induction motor (IM) in many drive applications noticeably go up. For the same cost and efficiency reasons, that increase of inverter fundamental output frequency cannot be followed with the increase of pulsewidth modulation (PWM) frequency. Therefore, a very low ratio between the PWM and motor fundamental frequencies is to be expected in the near future. In this paper, the shaft-sensorless drive performance is investigated at high speeds, with a very low sampling to fundamental frequency ratio. As a result, two main problems with rotor flux estimators were discovered: the integration problem in the current-based rotor flux model and the phase error in the voltage-based rotor flux model. Both problems were addressed, and a proper joint solution is suggested. The effectiveness of the proposed solution is tested in a model-reference-adaptive-system-based high-speed shaft-sensorless IM drive. The experimental results collected from the digitally controlled IM drive with a low frequency ratio validate the proposed solution.
4 September 2014 in IEEE Transactions on Industrial Electronics
A technique for stator-resistance-based thermal protection suitable for a low-cost vector-controlled induction machine (IM) drive is suggested in this paper. In order to provide accurate stator resistance monitoring at medium and high speeds, the dc signal injection-based method is selected. The main property of the scheme is that small regulated dc current is periodically injected in the stator windings without interrupting the flux and torque control loops. In the proposed scheme, inverter nonlinearities are properly compensated and accurate resistance estimation is achieved with minimal level of injected dc current. This results in consistent and controllable torque ripple, which is minimal and constant for any actual stator resistance value. Estimated stator resistance can be also used for control algorithm tuning. The method is implemented in a fixed-point microprocessor and tested on a low-cost shaft-sensorless IM drive under various operation modes.
15 August 2019 in IEEE Transactions on Power Delivery
Noninvasive contactless methods for electric power line monitoring based on magnetic field measurement have become an interesting topic for researchers and the electric power industry since introduction of the Smart Grid concept. By measuring and analyzing magnetic field originating from currents in power line conductors, it is possible to detect faults in the network. In medium voltage distribution networks, where a variety of different pole geometries are present, different criteria for fault detection have to be employed for each geometry, which complicates detection and influences accuracy. This paper proposes a novel approach for fault detection in medium voltage distribution networks which is based on processing of signals measured by low cost contactless magnetic field sensors. In order to create a generalized method for fault detection, a sequence of mathematical transformations of the measured magnetic field components is applied. A novel geometric transformation which eliminates influence of pole geometry is introduced, providing signals from which steady-state symmetrical components of the rotating magnetic field are computed. Those components are used as general fault detection criteria. The proposed approach is confirmed to be applicable for different fault types by a set of experiments on three-phase overhead power line model scaled to laboratory conditions.
16 October 2019 in IEEE Transactions on Industrial Electronics