Background: Obstructive sleep apnea (OSA) contributes to the onset and progression of atrial fibrillation (AF) and negatively affects AF ablation outcomes. OSA screening in AF patients is often conducted with the STOP-BANG questionnaire, although its validation is lacking. This study aims to evaluate the screening value of the STOP-BANG questionnaire and a home sleep apnea test (HSAT) device for OSA in patients referred for AF ablation. Methods: Patients referred for their first AF ablation and without prior OSA diagnosis underwent both the STOP-BANG questionnaire and a HSAT device based on peripheral arterial tonometry (PAT). Patients with a PAT-derived apnea-hypopnea index (pAHI) of 5 or more events per hour subsequently underwent clinical polysomnography (PSG). This PSG was used for definitive OSA diagnosis and to determine the diagnostic values of the STOP-BANG and HSAT. Results: Of 67 patients initially screened with the STOP-BANG and HSAT, 58 completed PSG after excluding those with pAHI < 5/hour or who declined further testing. Among these 58 patients, STOP-BANG (score ≥ 3) correctly screened 84% of cases, while HSAT was more accurate (97%, P -value < 0.002). Among the 67 initially screened patients, 56 (84%) received a new OSA diagnosis. Of these, 21 (38%) had mild OSA, 17 (30%) moderate OSA and 18 (32%) severe OSA. Conclusion: The high OSA prevalence highlights the importance of OSA screening in patients referred for AF ablation. In this cohort, HSAT demonstrated superior accuracy, compared to the STOP-BANG questionnaire and may be considered the preferred OSA screening tool in outpatient AF clinics. Graphical
Thermal imaging is a non-contact method for monitoring respiration activity during sleep. In this study, we evaluated its clinical application during overnight recordings in a sleep clinic. Five thermal cameras were used to detect breaths, the estimated respiration rate (RR), and inter-breath intervals (IBIs) in seven adults undergoing diagnostic polysomnography (PSG). Forty-five minutes of recordings were selected, consisting of 12 motionless and event-free segments. The thermal videos were processed using an adapted pre-existing thermal video processing algorithm. The respiration signals generated with the thermal cameras were validated against simultaneously recorded signals from the PSG system, the current gold standard for monitoring sleep. The results show a mean absolute error (MAE) ranging between 0.64 and 0.91 breaths per minute for the RR. Breath detection showed a sensitivity of 96.3%, and a precision of 94.1%. The MAE obtained between IBIs was 0.48 s, and the mean IBI variability difference recorded was 3.9 percentage points. In addition, the results from this clinical study show that the use of all five cameras and a single camera revealed no statistically significant differences, demonstrating the work towards a robust system. This first study of thermal cameras for the assessment of respiration in a clinical setting shows us the potential application of thermal imaging in clinical practice for respiration monitoring and establishes a foundation for further implementation in assessing sleep-disordered breathing.