Hubei Key Laboratory of Power Equipment and System Security for Integrated Energy, School of Electrical Engineering and Automation, Wuhan University, Wuhan, China
Auto-generated profile, based on publicly available information
Yanhui Huang
Hubei Key Laboratory of Power Equipment and System Security for Integrated Energy, School of Electrical Engineering and Automation, Wuhan University, Wuhan, China
An input-independent and output-series (IIOS) modular DC-DC converter with multiple input ports and high voltage conversion ratio can apply well to medium-voltage DC (MVDC) interface of distributed photovoltaics (PV). However, PV power mismatch will result in output voltage imbalance of the submodules (SMs), which is contrary to the standardized multi-module design. In this paper, a multiport modular DC-DC converter with low-loss series LC power balancing unit (PBU) is proposed to address this problem. An isolated DC-DC converter is employed as the SM, which consists of full-bridge (FB) circuit on the PV side and half-bridge (HB) circuit on the grid side. Independent maximum power point tracking (MPPT) can be realized by controlling the phase shift between the FB and the HB, while voltage balancing (or power balancing) of SMs can be achieved by regulating the phase shift between adjacent HBs. Only one inductor and one capacitor are used in the PBU and all the switches of SM turn on with zero-voltage switching (ZVS), which contributes to the low-cost and low-loss characteristic of the converter. Simulations and experiments are carried out to verify the validity of the theory.
22 June 2020 in IEEE Transactions on Power Electronics
A multiport DC/DC converter with cascaded submodules (SMs) can be employed in photovoltaic (PV) power generation system for its high step-up ratio. Consisting of multiple low-voltage (LV) input ports and one high-voltage (HV) output port, the multiport converter is more likely to suffer short-circuit faults than a two-port converter. To ensure reliable operation of the converter, its short-circuit fault-tolerant capability should be necessarily considered. In this paper, a short-circuit fault-tolerant topology for multiport cascaded DC/DC converter in PV power generation system is proposed to satisfy the requirements of fault tolerance ability. When one or more short-circuit faults occur at LV ports, the proposed topology guarantees the normal operation of other fault-free SMs. When a short-circuit fault occurs at the HV port, the short-circuit fault current can be interrupted rapidly by the fault-tolerant topology, which protects the converter from a large current surge. The fault-tolerant ability of the proposed topology is verified by both simulation and experimental results.
18 August 2021 in IEEE Transactions on Power Electronics
In the traditional dc distribution networks with both a low-voltage dc (LVdc) and a medium-voltage dc (MVdc) bus, dc units, such as photovoltaics solar, storage devices, and dc loads, are connected to the LVdc bus through LVdc converters, such as dc/dc boost converters and bidirectional buck–boost dc/dc converters. In this approach, no galvanic isolation is provided and two power conversion stages are needed between the dc units and the MVdc grid, hence leading to a high number of converters and higher costs. To address these shortcomings, this article proposes a novel multiport dc solid-state transformer (MDCSST) to interface these dc units directly to the MVdc bus. Multiple modules are connected in series on the medium-voltage side to the MVdc bus, whereas dc units are independently connected on the low-voltage side of the MDCSST. Compared with a traditional dc distribution network, the proposed scheme connects dc units to the MVdc bus without an extra converter or an LVdc bus, therefore, saving cost and reducing the number of converters. In addition, dc units are galvanically isolated by high-frequency transformers. The main challenge of the MDCSST is to resolve the voltage-imbalance problem on the MVdc side, which is caused by the dc units’ power differences. An LC branch is used to balance the voltages among the modules and to transfer their differential powers. Simulations and experiments were carried out to validate the proposed approach and verify the theoretical analysis.
DC–DC converters with output-series cascaded submodules (SMs) are required for the medium-voltage direct current (MVDC) grid interface of photovoltaic (PV) systems. However, the mismatched power of PV arrays can cause an imbalance among the output voltages of SMs. In order to address this problem, in this paper, a multi-port cascaded DC–DC converter is established on the basis of a voltage balancer (VB) with a novel power feedforward voltage-balancing control strategy. The converter has multiple input terminals for the PV arrays and an output terminal connected to the MVDC grid. The differential power is regulated from one SM to another through the VB, ensuring that the SM output voltages are equalized. Simulation and experimental results suggest that the proposed converter has an excellent voltage-balancing capacity and dynamic performance.
26 April 2021 in IEEE Journal of Emerging and Selected Topics in Power Electronics
The input-independent and output-series (IIOS) structure is often used in the high step-up ratio converters required for medium-voltage dc (MVdc) grid interface of photovoltaic (PV) systems, which achieves high voltage gain and ensures high efficiency. However, due to the characteristics of IIOS structure, when some PV arrays are shadowed or malfunction, the generated power of these modules will be mismatched. Mismatched power will result in output capacitor voltages deviating from the rated value, which is not conducive to the standardized multimodule design. Besides, voltages of some PV arrays will deviate from their maximum power point (MPP) value, leading to a decrease in the total generated power. In order to balance the module output voltages of the IIOS structure, this article proposes bidirectional buck-boost and series LC- based power balancing units (LC-PBUs) for PV dc collection systems. Compared with a traditional solution, nearly half of the switches are saved and half of the inductors are displaced by small inductors. Power balance can be achieved through the LC -PBUs by controlling the duty ratio and the phase of the pulse-width modulation (PWM) signal. Simulations and experiments are carried out to verify the effectiveness of LC -PBU under power sags.
14 June 2022 in IEEE Transactions on Industrial Electronics
The input independent output series dc/dc converter has one stage of power conversion, which has low cost and high efficiency. However, shadow occlusion, dust coverage, and manufacturing differences will cause power mismatch of the photovoltaic panels, which in turn causes an unbalanced output voltage. To avoid device damage and power degradation caused by unbalanced voltage, a novel topology based on multiwinding transformer is proposed. By multiplexing the switches of each sub-module (SM), this topology can transmit the mismatched power among all the SMs and balance the output voltages. In the traditional method, the mismatched power can only be transferred between adjacent SMs. When the power mismatched SMs are far away, differential power will go through many SMs to reach the target one, causing unnecessary power losses. In the proposed topology, mismatched power can be directly transferred to the target SM; therefore, it has higher efficiency. Moreover, all the switches have zero voltage switching, which further improves the efficiency. One-third of the switches in the proposed topology have lower current stress than the traditional topology. The hardware cost can be reduced. Finally, the proposed topology is verified by simulation and experiment of 1 kW.