Ivor Dukić

Ivor Dukić

Auto-generated profile, based on publicly available information

Ivor Dukić

Faculty of Medicine Osijek, Department of Biophysics and Medical Physics, J. J. Strossmayer University of Osijek, HR-31000 Osijek, Croatia

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 May 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LŠLuka Šimić
Luka Šimić
DFDario Faj
Dario Faj
ATAnja Tomić
Anja Tomić
IDIvor Dukić
Ivor Dukić
HBHrvoje Brkić
Hrvoje Brkić
VKVjekoslav Kopacin
Vjekoslav Kopacin
When pregnant patients undergo diagnostic and therapeutic radiological procedures, the unborn child is exposed to an increased risk due to the use of ionizing radiation; therefore, the fetal dose must be estimated and optimized. Tools and methods routinely used for fetal dose estimation lack better personalization of patients. To address this, we developed a software tool for creating phantoms at different pregnancy stages and with varying patient anatomies to further personalize fetal dose estimation using measurements and Monte Carlo simulations. The tool is developed and incorporated into 3DSlicer version 5.6.2 as a plugin. Phantoms are created based on a real patient phantom, Tena, and physiological data for use in radiological protection. Phantoms are developed with only soft, lung, and bone tissue substitutes, represented for the mother and unborn child. This enables the construction of segmented voxel models as well as mesh models (with the ability to export geometries to DICOM format) of the anatomical structures of pregnant women. Additionally, it allows real patient image registration to enable better personalization of the phantom. The tool can help decrease uncertainty in fetal dose estimation, as well as simplify and accelerate the process of fetal dose estimation. It is released publicly to enable further research.

14 October 2026 in Oral
Verified
Journal Article
Open access
PDF file
DFDario Faj
Dario Faj
ZMZoran Mirkov
Zoran Mirkov
IDIvor Dukić
Ivor Dukić
HBHrvoje Brkić
Hrvoje Brkić
Objectives. To investigate effective doses and relevant absorbed organ doses for typical intraoral radiographic imaging procedures in adult patients. Variations of relevant absorbed organ doses and effective doses due to changes in imaging parameters and X-ray tube positioning were investigated. Conversion factors for estimating effective doses from incident air kerma (Ka,i) and kerma area product are proposed. Materials and Methods. Different imaging parameters and geometries obtained from previously published data from Serbia were simulated using Monte Carlo simulation and a computational anthropomorphic phantom. The relevant absorbed organ doses and effective doses for different exposure parameters and geometries were then compared to Ka,i and analyzed. Since an obsolete intraoral unit with a focus-to-skin distance of 10 cm, a 50 kVp beam and circular collimator with 5 cm diameter was found in the previous investigation, these imaging parameters were also included in the simulations. Results. For typical Ka,i for imaging protocols found in Serbia, effective doses for imaging of the left upper molar in an adult person were 2.9 µSv and 5.4 µSv for 60 kVp and 70 kVp beams, respectively. The highest absorbed organ doses were observed for the thyroid, eye lenses, salivary glands and brain, reaching up to 47.2 µGy, 71.4 µGy, 63.1 µGy and 26.2 µGy, respectively. For poorly optimized imaging protocols, these values were higher. Furthermore, for the obsolete intraoral units used, all doses were considerably higher and the typical effective dose was 16.8 µSv with thyroid dose of 105.3 µGy. Using rectangular instead of circular collimators decreased effective dose by 25% to 52.7% and absorbed organ doses by 43.3% to 84.5% in all simulated situations. Simulated positioning errors could change eye lens or thyroid absorbed organ dose by up to a factor of two when a rectangular collimator is used and up to four times when a circular collimator is used. Conclusions. Though the effective and absorbed organ doses from intraoral imaging are very low, this imaging can be further optimized by using optimal exposure parameters, rectangular collimators, and proper positioning of the X-ray tube.