Andreas Scherz

Andreas Scherz

Auto-generated profile, based on publicly available information

Andreas Scherz

European XFEL

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 June 2017 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Thomas TschentscherThomas Tschentscher
Thomas Tschentscher
Christian BresslerChristian Bressler
Christian Bressler
JGJan Gruenert
Jan Gruenert
AMAnders Madsen
Anders Madsen
AMAdrian Mancuso
Adrian Mancuso
UZUlf Zastrau
Ulf Zastrau
European XFEL is a free-electron laser (FEL) user facility providing soft and hard X-ray FEL radiation to initially six scientific instruments. Starting user operation in fall 2017 European XFEL will provide new research opportunities to users from science domains as diverse as physics, chemistry, geo- and planetary sciences, materials sciences or biology. The unique feature of European XFEL is the provision of high average brilliance in the soft and hard X-ray regime, combined with the pulse properties of FEL radiation of extreme peak intensities, femtosecond pulse duration and high degree of coherence. The high average brilliance is achieved through acceleration of up to 27,000 electron bunches per second by the super-conducting electron accelerator. Enabling the usage of this high average brilliance in user experiments is one of the major instrumentation drivers for European XFEL. The radiation generated by three FEL sources is distributed via long beam transport systems to the experiment hall where the scientific instruments are located side-by-side. The X-ray beam transport systems have been optimized to maintain the unique features of the FEL radiation which will be monitored using build-in photon diagnostics. The six scientific instruments are optimized for specific applications using soft or hard X-ray techniques and include integrated lasers, dedicated sample environment, large area high frame rate detector(s) and computing systems capable of processing large quantities of data.

4 September 2015 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
JSJ. Stöhr
J. Stöhr
ASA. Scherz
A. Scherz
X-ray absorption by matter has long been described by the famous Beer-Lambert law. Here, we show how this fundamental law needs to be modified for high-intensity coherent x-ray pulses, now available at x-ray free electron lasers, due to the onset of stimulated elastic forward scattering. We present an analytical expression for the modified polarization-dependent Beer-Lambert law for the case of resonant core-to-valence electronic transitions and incident transform limited x-ray pulses. Upon transmission through a solid, the resonant absorption and dichroic contrasts are found to vanish with increasing x-ray intensity, with the stimulation threshold lowered by orders of magnitude through a resonant superradiantlike effect. Our results have broad implications for the study of matter with x-ray lasers.

6 July 2016 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
BWB. Wu
B. Wu
TWT. Wang
T. Wang
CGC. E. Graves
C. E. Graves
DZD. Zhu
D. Zhu
WSW. F. Schlotter
W. F. Schlotter
JSJ. Stöhr
J. Stöhr
X-ray diffractive imaging with laterally coherent x-ray free-electron laser (XFEL) pulses is increasingly utilized to obtain ultrafast snapshots of matter. Here we report the amazing disappearance of single-shot charge and magnetic diffraction patterns recorded with resonantly tuned, narrow bandwidth XFEL pulses. Our experimental results reveal the exquisite sensitivity of single-shot charge and magnetic diffraction patterns of a magnetic film to the onset of field-induced stimulated elastic x-ray forward scattering. The loss in diffraction contrast, measured over 3 orders of magnitude in intensity, is in remarkable quantitative agreement with a recent theory that is extended to include diffraction.

23 August 2022 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
NGNatalia Gerasimova
Natalia Gerasimova
DCD. La Civita
D. La Civita
LSL. Samoylova
L. Samoylova
MVMaurizio Vannoni
Maurizio Vannoni
RVR. Villanueva
R. Villanueva
ASA. Scherz
A. Scherz
The SASE3 soft X-ray beamline at the European XFEL has been designed and built to provide experiments with a pink or monochromatic beam in the photon energy range 250–3000 eV. Here, the focus is monochromatic operation of the SASE3 beamline, and the design and performance of the SASE3 grating monochromator are reported. The unique capability of a free-electron laser source to produce short femtosecond pulses of a high degree of coherence challenges the monochromator design by demanding control of both photon energy and temporal resolution. The aim to transport close to transform-limited pulses poses very high demands on the optics quality, in particular on the grating. The current realization of the SASE3 monochromator is discussed in comparison with optimal design performance. At present, the monochromator operates with two gratings: the low-resolution grating is optimized for time-resolved experiments and allows for moderate resolving power of about 2000–5000 along with pulse stretching of a few to a few tens of femtoseconds RMS, and the high-resolution grating reaches a resolving power of 10 000 at the cost of larger pulse stretching.

29 July 2024 in Nature Physics
Verified
Journal Article
Open access
PDF file
LMLaurent Mercadier
Laurent Mercadier
ABAndrei Benediktovitch
Andrei Benediktovitch
ŠKŠpela Krušič
Špela Krušič
JKJoshua J. Kas
Joshua J. Kas
JSJustine Schlappa
Justine Schlappa
NRNina Rohringer
Nina Rohringer
Warm dense matter is at the boundary between a plasma and a condensed phase and plays a role in astrophysics, planetary science and inertial confinement fusion research. However, its electronic structure and ionic structure upon irradiation with strong laser pulses remain poorly understood. Here, we use an intense and ultrafast X-ray free-electron laser pulse to simultaneously create and characterize warm dense copper using L-edge X-ray absorption spectroscopy over a large irradiation intensity range. Below a pulse intensity of 1015 W cm−2, an absorption peak below the L edge appears, originating from transient depletion of the 3d band. This peak shifts to lower energy with increasing intensity, indicating the movement of the 3d band upon strong X-ray excitation. At higher intensities, substantial ionization and collisions lead to the transition from reverse saturable absorption to saturable absorption of the X-ray free-electron laser pulse, two nonlinear effects that hold promise for X-ray pulse-shaping. We employ theoretical calculations that combine a model based on kinetic Boltzmann equations with finite-temperature real-space density-functional theory to interpret these observations. The results can be used to benchmark non-equilibrium models of electronic structure in warm dense matter.

8 September 2011 in Physical Review B
Verified
Journal Article
Open access
PDF file
OŠO. Šipr
O. Šipr
JMJ. Minár
J. Minár
ASA. Scherz
A. Scherz
HWH. Wende
H. Wende
HEHubert Ebert
Hubert Ebert
The theoretical description of photoemission spectra of transition metals was greatly improved recently by accounting for the correlations between the d electrons within the local spin-density approximation (LSDA) plus dynamical mean-field theory (DMFT). We assess the improvement of the LSDA+DMFT over the plain LSDA in x-ray absorption spectroscopy, which—unlike the photoemission spectroscopy—is probing unocccupied electronic states. By investigating the L 2,3 edge x-ray absorption near-edge structure (XANES) and x-ray magnetic circular dichroism (XMCD) of Fe, Co, and Ni, we find that the LSDA+DMFT improves the LSDA results, in particular concerning the asymmetry of the L3 white line. Differences with respect to the experiment, nevertheless, remain—particularly concerning the ratio of the intensities of the L3 and L2 peaks. The changes in the XMCD peak intensities invoked by the use of the LSDA+DMFT are a consequence of the improved description of the orbital polarization and are consistent with the XMCD sum rules. Accounting for the core hole within the final-state approximation does not generally improve the results. This indicates that to get more accurate L 2,3 edge XANES and XMCD spectra, one has to treat the core hole beyond the final-state approximation.