Daniel Sang-Won Park

Daniel Sang-Won Park

Auto-generated profile, based on publicly available information

Daniel Sang-Won Park

Center for Bio-Modular Multi-Scale Systems, Louisiana State University, Baton Rouge, USA

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 October 2018 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
CCCamila Campos
Camila Campos
SGSachindra S. T. Gamage
Sachindra S. T. Gamage
JJJoshua M. Jackson
Joshua M. Jackson
MWMalgorzata Witek
Malgorzata Witek
DPDaniel S. Park
Daniel S. Park
SSSteven Soper
Steven Soper
Cell-free DNA (cfDNA) is a liquid biopsy marker that can carry signatures (i.e., mutations) associated with certain pathological conditions. Therefore, the extraction of cfDNA from a variety of clinical samples can be an effective and minimally invasive source of markers for disease detection and subsequent management. In the oncological diseases, circulating tumor DNA (ctDNA), a cfDNA sub-class, can carry clinically actionable mutations and coupled with next generation sequencing or other mutation detection methods provide a venue for effective in vitro diagnostics. However, cfDNA mutational analyses require high quality inputs. This necessitates extraction platforms that provide high recovery over the entire ctDNA size range (50 → 150 bp) with minimal interferences (i.e., co-extraction of genomic DNA), and high reproducibility with a simple workflow. Herein, we present a novel microfluidic solid-phase extraction device (μSPE) consisting of a plastic chip that is activated with UV/O3 to generate surface-confined carboxylic acid functionalities for the μSPE of cfDNA. The μSPE uses an immobilization buffer (IB) consisting of polyethylene glycol and salts that induce cfDNA condensation onto the activated plastic microfluidic surface. The μSPE consists of an array of micropillars to increase extraction bed load (scalable to loads >700 ng of cfDNA) and can be produced at low-cost using replication-based techniques. The entire μSPE can be fabricated in a single molding step negating the need for adding additional extraction supports to the device simplifying production and keeping device and assay cost low. The μSPE allowed for recoveries >90% of model cfDNA fragments across a range of sizes (100–700 bp) and even the ability to extract efficiently short cfDNA fragments (50 bp, >70%). In addition, the composition of the IB allowed for reducing the interference of co-extracted genomic DNA. We demonstrated the clinical utility of the μSPE by quantifying the levels of cfDNA in healthy donors and patients with non-small-cell lung and colorectal cancers. μSPE extracted cfDNA from plasma samples was also subjected to a ligase detection reaction (LDR) for determining the presence of mutations in the KRAS gene for colorectal and non-small cell lung cancer patients.

1 March 2017 in Nano Convergence
Verified
Journal Article
Open access
PDF file
BFBahador Farshchian
Bahador Farshchian
AAAlborz Amirsadeghi
Alborz Amirsadeghi
JCJunseo Choi
Junseo Choi
DPDaniel S. Park
Daniel S. Park
NKNamwon Kim
Namwon Kim
SPSunggook Park
Sunggook Park
Microfluidic devices where the microchannel walls were decorated with micro and nanostructures were fabricated using 3D nanomolding. Using 3D molded microfluidic devices with microchannel walls decorated with microscale gratings, the fluid mixing behavior was investigated through experiments and numerical simulation. The use of microscale gratings in the micromixer was predicated by the fact that large obstacles in a microchannel enhances the mixing performance. Slanted ratchet gratings on the channel walls resulted in a helical flow along the microchannel, thus increasing the interfacial area between fluids and cutting down the diffusion length. Increasing the number of walls decorated with continuous ratchet gratings intensified the strength of the helical flow, enhancing mixing further. When ratchet gratings on the surface of the top cover plate were aligned in a direction to break the continuity of gratings from the other three walls, a stack of two helical flows was formed one above each other. This work concludes that the 3D nanomolding process can be a cost-effective tool for scaling-up the fabrication of microfluidic mixers with improved mixing efficiencies.

9 August 2018 in Biomedical Microdevices
Verified
Journal Article
Closed access
PDF file
JBJacob Beckham
Jacob Beckham
FAFaiz Alam
Faiz Alam
VOVictor Omojola
Victor Omojola
Thomas Foster ScherrThomas Foster Scherr
Thomas Foster Scherr
AGAmy Guitreau
Amy Guitreau
WMWilliam Monroe
William Monroe

2 July 2020 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
DPDaniel Sang-Won Park
Daniel Sang-Won Park
BYBrandon M. Young
Brandon M. Young
BYByoung Hee You
Byoung Hee You
VSVarshni Singh
Varshni Singh
SSSteven Soper
Steven Soper
MMMichael C. Murphy
Michael C. Murphy
An improved, laser-induced fluorescence-based micro-optical biosensor was designed and fabricated, with cyclic olefin copolymer (COC) optical waveguides, a poly(methyl methacrylate) (PMMA) fluidic substrate with an array of microlenses, and a COC coupling prism integrated with the waveguide substrate or cover plate. The double-sided hot embossed fluidic substrate had sampling zone microchannels on the bottom and microlenses on the top. Dissolved COC injected into polydimethylsiloxane (PDMS) lost molds embedded the waveguides in the PMMA cover plate and formed the integrated coupling prism. The embedded COC waveguide was flycut down to $50~\mu \text{m}$ . The cover plate and shallow, 1:20 aspect ratio, microchannels were thermal fusion bonded using a pressure-assisted boiling point control system, without sagging. The large COC prism coupled better to the waveguide. The highest intensity evanescent excitation of the waveguide was obtained near the critical angle. The maximum signal-to-noise ratio (SNR) was 119 and the lowest detection limit was 7.34 $\times 10^{\mathbf {-20}}$ mol at a SNR of 2 for a $100~\mu \text{m}$ wide by $50~\mu \text{m}$ deep waveguide. The microlenses highly focused the fluorescent radiation in the sampling zone. The microfabricated waveguide enables rapid, low-cost detection of fluorescent samples with high SNR, a low detection limit, and high sampling efficiency. [2020-0067]

2 September 2021 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
CBChristopher R. Brown
Christopher R. Brown
XZXiaoxiao Zhao
Xiaoxiao Zhao
TPTaehyun Park
Taehyun Park
Pinchuan ChenPinchuan Chen
Pinchuan Chen
BYByoung Hee You
Byoung Hee You
MMMichael C. Murphy
Michael C. Murphy
Chip-to-chip and world-to-chip fluidic interconnections are paramount to enable the passage of liquids between component chips and to/from microfluidic systems. Unfortunately, most interconnect designs add additional physical constraints to chips with each additional interconnect leading to over-constrained microfluidic systems. The competing constraints provided by multiple interconnects induce strain in the chips, creating indeterminate dead volumes and misalignment between chips that comprise the microfluidic system. A novel, gasketless superhydrophobic fluidic interconnect (GSFI) that uses capillary forces to form a liquid bridge suspended between concentric through-holes and acting as a fluid passage was investigated. The GSFI decouples the alignment between component chips from the interconnect function and the attachment of the meniscus of the liquid bridge to the edges of the holes produces negligible dead volume. This passive seal was created by patterning parallel superhydrophobic surfaces (water contact angle ≥ 150°) around concentric microfluidic ports separated by a gap. The relative position of the two polymer chips was determined by passive kinematic constraints, three spherical ball bearings seated in v-grooves. A leakage pressure model derived from the Young–Laplace equation was used to estimate the leakage pressure at failure for the liquid bridge. Injection-molded, Cyclic Olefin Copolymer (COC) chip assemblies with assembly gaps from 3 to 240 µm were used to experimentally validate the model. The maximum leakage pressure measured for the GSFI was 21.4 kPa (3.1 psig), which corresponded to a measured mean assembly gap of 3 µm, and decreased to 0.5 kPa (0.073 psig) at a mean assembly gap of 240 µm. The effect of radial misalignment on the efficacy of the gasketless seals was tested and no significant effect was observed. This may be a function of how the liquid bridges are formed during the priming of the chip, but additional research is required to test that hypothesis.

12 June 2020 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
XZXiaoxiao Zhao
Xiaoxiao Zhao
DPDaniel S.-W. Park
Daniel S.-W. Park
SSSteven Soper
Steven Soper
MMMichael C. Murphy
Michael C. Murphy
Existing methods for sealing chip-to-chip (or module-to-motherboard) microfluidic interconnects commonly use additional interconnect components (O-rings, gaskets, and tubing), and manual handling expertise for assembly. Novel gasketless superhydrophobic fluidic interconnects (GSFIs) sealed by transparent superhydrophobic surfaces, forming liquid bridges between the fluidic ports for fluidic passages were demonstrated. Two test platforms were designed, fabricated, and evaluated, a multi-port chip system (ten interconnects) and a modules-on-a-motherboard system (four interconnects). System assembly in less than 3 sec was done by embedded magnets and pin-in-V-groove structures. Flow tests with deionized (DI) water, ethanol/water mixture, and plasma confirmed no leakage through the gasketless interconnects up to a maximum flow rate of 100 μL/min for the multi-port chip system. The modules-on-a-motherboard system showed no leakage of water at a flow rate of 20 μL/min and a pressure drop of 3.71 psi. Characterization of the leakage pressure as a function of the surface tension of the sample liquid in the multi-port chip system revealed that lower surface tension of the liquid led to lower static water contact angles on the superhydrophobic-coated substrate and lower leakage pressures. The high-density, rapidly assembled, gasketless interconnect technology will open up new avenues for chip-to-chip fluid transport in complex microfluidic modular systems. [2020-0168]