Hyperthermia treatments are successful adjuvants to conventional cancer therapies in which the tumor is sensitized by heating. To monitor and guide the hyperthermia treatment, measuring the tumor a...
23 June 2022 in Computer Methods in Applied Mechanics and Engineering
Hyperthermia treatment consists of elevating the temperature of the tumor to increase the effectiveness of radiotherapy and chemotherapy. Hyperthermia treatment planning (HTP) is an important tool to optimize treatment quality using pre-treatment temperature predictions. The accuracy of these predictions depends on modeling uncertainties such as tissue properties and positioning. In this study, we evaluated if HTP accuracy improves when the patient is imaged inside the applicator at the start of treatment. Because perfusion is a major uncertainty source, the importance of accurate treatment position and anatomy was evaluated using different perfusion values. Volunteers were scanned using MR imaging without (“planning setup”) and with the MR-compatible hyperthermia device (“treatment setup”). Temperature-based quality indicators were used to assess the differences between the standard, apparent and the optimized hyperthermia dose. We conclude that pre-treatment imaging can improve HTP predictions accuracy but also, that tissue perfusion modelling is crucial if temperature-based optimization is applied.
4 February 2025 in IEEE Transactions on Control Systems Technology
During a mild hyperthermia treatment, tumors are heated to temperatures ranging from 39 ∘C to 45 ∘C for 60–90 min. This thermal therapy can be a successful adjuvant to conventional cancer treatments such as chemotherapy and radiotherapy. In order to extract the maximum potential from the thermal therapy, it is crucial to heat the tumor to the desired therapeutic temperature while minimally heating the healthy tissue. Due to the recent development of magnetic resonance (MR)-compatible heating devices, MR thermometry techniques can be employed to noninvasively monitor the internal patient temperature in real time. This development enables closed-loop control strategies to improve the clinical value of the hyperthermia treatment. In this article, we propose a novel model predictive control (MPC) solution based on the alternating direction method of multipliers in combination with constraint removal techniques to compute optimal control inputs for radio frequency (RF)-based mild hyperthermia in real time based on models with 105–106 states and temperature safety constraints. We validated the proposed controller on high-fidelity patient models with and without patient model mismatches. We will show that the proposed control strategy can track a desired tumor temperature reference, while ensuring patient safety through 105–106 constraints and maintaining real-time feasibility with a computation time of 6 s, which is sufficiently fast considering the thermal dynamics.
23 November 2023 in International Journal of Hyperthermia
Purpose: A crucial aspect of quality assurance in thermal therapy is periodic demonstration of the heating performance of the device. Existing methods estimate the specific absorption rate (SAR) from the temperature rise after a short power pulse, which yields a biased estimate as thermal diffusion broadens the apparent SAR pattern. To obtain an unbiased estimate, we propose a robust frequency-domain method that simultaneously identifies the SAR as well as the thermal dynamics.Methods: We propose a method consisting of periodic modulation of the FUS power while recording the response with MR thermometry (MRT). This approach enables unbiased measurements of spatial Fourier coefficients that encode the thermal response. These coefficients are substituted in a generic thermal model to simultaneously estimate the SAR, diffusivity, and damping. The method was tested using a cylindrical phantom and a 3 T clinical MR-HIFU system. Three scenarios with varying modulation strategies are chosen to challenge the method. The results are compared to the well-known power pulse technique.Results: The thermal diffusivity is estimated at 0.151 mm2s-1 with a standard deviation of 0.01 mm2s-1 between six experiments. The SAR estimates are consistent between all experiments and show an excellent signal-to-noise ratio (SNR) compared to the well established power pulse method. The frequency-domain method proved to be insensitive to B0-drift and non steady-state initial temperature distributions.Conclusion: The proposed frequency-domain estimation method shows a high SNR and provided reproducible estimates of the SAR and the corresponding thermal diffusivity. The findings suggest that frequency-domain tools can be highly effective at estimating the SAR from (biased) MRT data acquired during periodic power modulation.