Instituto de Instrumentacin para Imagen Molecular, Centro Mixto CSICUniversitat Politcnica de Valncia, Valencia, Spain

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2021 in Medical Physics
Verified
Journal Article
Open access
PDF file
NCNeus Cucarella
Neus Cucarella
JBJohn Barrio
John Barrio
ELEfthymios Lamprou
Efthymios Lamprou
CVCelia Valladares
Celia Valladares
JBJose María Benlloch
Jose María Benlloch
AGAntonio J. Gonzalez
Antonio J. Gonzalez
Purpose: Detectors for positron emission tomography (PET) typically use two types of scintillation crystals, pixelated or monolithic. A variant of these types of scintillators are the so‐called semi‐monolithic crystals. They consist of a monolithic crystal segmented in one direction in pieces called slabs. These scintillators have the potential to successfully combine the benefits of pixelated and monolithic configurations, providing good timing and spatial resolutions as well as the capacity to decode the depth of interaction (DOI) information. In this work, the timing performance of a detector based on semi‐monolithic crystals was studied in depth. The energy response was also evaluated.Methods: The semi‐monolithic detector consists of 1 × 24 LYSO slabs of 25.4 × 12 × 0.95 mm3 each. The bottom surface of the slabs is coupled to an array of 8 × 8 silicon photomultipliers (SiPMs) of 3 × 3 mm2 active area, 50 μm cell size and 3.2 mm pitch. The 64 output signals were independently readout by the TOFPET2 ASIC. In order to achieve the best coincidence time resolution (CTR), four different time walk corrections were tested. Additional work investigated the best method of combining the timestamps belonging to the same event.Results: The resolvability of the slabs in the measured flood maps improves with the thickness of a light guide placed in between the scintillators and photosensors. The energy resolution does not change significantly with values as good as 13.7%. Regarding the CTR, values of 335.8, 363, 369.8, and 402.5 ps have been obtained for the whole detector for no light guide, 0.5, 1.0, and 1.5 mm thickness light guide cases, respectively. These values further improve to 276.1, 302.6, 305.6 and 336.2 ps, respectively, when energy‐weighted averaging of timestamps is applied.Conclusions: We have shown both an excellent timing resolution and good energy resolution for a PET detector based on semi‐monolithic crystals. The use of light guides of different thicknesses does not significantly affect the energy resolution of the whole detector, but the timing capabilities slightly worsen with the increasing thickness of the light guide.

1 December 2022 in Bio-Algorithms and Med-Systems
Verified
Journal Article
Open access
PDF file
AGAndrea Gonzalez-Montoro
Andrea Gonzalez-Montoro
JBJulio Barbera
Julio Barbera
DGDavid Sanchez Gonzalo
David Sanchez Gonzalo
AMAlvaro Mondejar
Alvaro Mondejar
MFMarta Freire
Marta Freire
JBJose M. Benlloch
Jose M. Benlloch
In this article, we present the geometrical design and preliminary results of a high sensitivity organ-specific Positron Emission Tomography (PET) system dedicated to the study of the human brain. The system, called 4D-PET, will allow accurate imaging of brain studies due to its expected high sensitivity, high 3D spatial resolution and, by including precise photon time of flight (TOF) information, a boosted signal-to-noise ratio (SNR). The 4D-PET system incorporates an innovative detector design based on crystal slabs (semi-monolithic) that enables accurate 3D photon impact positioning (including photon Depth of Interaction (DOI) measurement), while providing a precise determination of the photon arrival time to the detector. The detector includes a novel readout system that reduces the number of detector signals in a ratio of 4:1 thus, alleviating complexity and cost. The analog output signals are fed to the TOFPET2 ASIC (PETsys) for scalability purposes. The present manuscript reports the evaluation of the 4D-PET detector, achieving best values 3D resolution values of <1.6 mm (pixelated axis), 2.7±0.5 mm (monolithic axis) and 3.4±1.1 (DOI axis) mm; 359 ± 7 ps coincidence time resolution (CTR); 10.2±1.5 % energy resolution; and sensitivity of 16.2% at the center of the scanner (simulated). Moreover, a comprehensive description of the 4D-PET architecture (that includes 320 detectors), some pictures of its mechanical assembly, and simulations on the expected image quality are provided.

1 August 2023 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
JBJohn Barrio
John Barrio
NCNeus Cucarella
Neus Cucarella
MFMarta Freire
Marta Freire
CVCelia Valladares
Celia Valladares
JBJose M. Benlloch
Jose M. Benlloch
AGAntonio J. Gonzalez
Antonio J. Gonzalez
The use of detectors based on semi-monolithic crystals can be of interest to clinical PET scanners due to their time of flight (TOF) and depth of interaction (DOI) capabilities. In this work, timing and energy characterization of four different detector configurations based on arrays of 8 LYSO slabs of 25.4×3.1×20 mm each coupled to SiPMs have been carried out. On the one hand, two different surface treatments have been studied. In one configuration, all the slab surfaces were treated with ESR (named ESR). In the other configuration, a retroreflector layer was added to the entrance face and the pixelated external faces were painted black (named ESR+B+RR). On the other hand, two different SiPM array models belonging to the series S13 and S14 from Hamamatsu Photonics were also compared. In all cases, the readout was performed by the TOFPET2 ASIC. The results show an energy resolution and a detector time resolution (DTR) as good as 12.5% and 193 ps, respectively, for the ESR treatment and the S13 photosensor. For the ESR+B+RR treatment and S13, the energy resolution and DTR are 14.6% and 238 ps, respectively. When using the S14, the energy resolutions and DTRs are, respectively, 11.6% and 219 ps for the ESR treatment, and 14.2% and 339 ps for the ESR+B+RR treatment.

11 June 2024 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
AGAndrea Gonzalez-Montoro
Andrea Gonzalez-Montoro
SJSantiago Jiménez-Serrano
Santiago Jiménez-Serrano
JÁJorge Álamo
Jorge Álamo
JBJulio Barberá
Julio Barberá
ALAlejandro Lucero
Alejandro Lucero
JBJose M. Benlloch
Jose M. Benlloch
Positron Emission Tomography (PET) imaging is the molecular technique of choice for studying many illnesses, including the ones related to the brain. Nevertheless, the use of PET scanners in neurology is limited by several factors, such as their limited availability for brain imaging due to the high oncology demand for PET and the low sensitivity and poor spatial resolution in the brain of the standard PET scanners. To expand the PET application in neurology, brain-specific systems with increased clinical and physical sensitivities and higher spatial resolution are required. The present work reports on the design and development process of a compact dedicated PET scanner suitable for human brain imaging. This paper includes the description and experimental validation of the detector components and their implementation in a full-size system called 4D-PET. The detector has been designed to simultaneously provide photon DOI and TOF information. It is based on the semi-monolithic LYSO modules optically coupled to SiPMs and connected to a multiplexing readout. The analog output signals are fed to the PETsys TOFPET2 ASIC circuits enabling scalability of the readout. The evaluation of the 4D-PET modules resulted in average detector resolutions of 2.111.0 mm, 3.411.8 mm, and 38619 ps for the y-(transaxial direction), DOI-, and CTR TOF, respectively. The preliminary 4D-PET imaging performance is reported through simulations and, for the first time, through the real reconstructed images (collected in the La Fe Hospital, Valencia).

3 March 2025 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Open access
NCNeus Cucarella
Neus Cucarella
JBJohn Barrio
John Barrio
DGDavid Sanchez Gonzalo
David Sanchez Gonzalo
JBJose M. Benlloch
Jose M. Benlloch
AGAntonio J. Gonzalez
Antonio J. Gonzalez
Traditional PET detectors based on pixelated scintillation crystals with single-ended readout do not provide depth of interaction (DOI) information in an easy and costeffective way. In this work, we propose a PET detector with singleended readout and 1:1 coupling, based on arrays of naked pixelated crystals that are glued in one direction, and optically separated in the other one. We have named this approach as pseudo-slab. In this configuration, some of the optical photons will propagate in the glued direction, generating a light distribution from which DOI information can be retrieved. We have characterized four different detector configurations, all of them consisting of a linear array of 1 8 LYSO crystals of 3 3 20 mm3 each, with an optical glue of approximately 70 μJm in between them. The top and bottom faces are polished, and with a different number of unpolished lateral surfaces (2 versus 4) and different wrappings (Enhanced Specular Reflector versus BaSO4). The results obtained for the four detector configurations show energy resolutions ranging from 8.5% to 9.8% and coincidence time resolutions (with a reference pixel) below 290 ps for all cases using only the fastest timestamp and close to 230 ps when energy-weighted averaging of multiple timestamps is applied (corresponding to 182 ps detector time resolution). Regarding DOI performance, all configurations provide DOI information, showing a better performance with more number of unpolished faces and also when using BaSO4 as a reflector.

29 May 2023 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
CVCelia Valladares
Celia Valladares
JBJohn Barrio
John Barrio
MFMarta Freire
Marta Freire
NCNeus Cucarella
Neus Cucarella
ELEfthymios Lamprou
Efthymios Lamprou
AGAntonio J. Gonzalez
Antonio J. Gonzalez
The HyPET project proposes a hybrid dedicated time of flight-positron emission tomography for prostate imaging, with pixelated detector blocks in the front layer and monolithic blocks in the back layer. In this work, four detector configurations have been experimentally evaluated for the rear detector layer. The detector configuration consists of LYSO monolithic blocks with the same size (25.4 mm $\times25.4$ mm) but different thicknesses (5, 7.5, 10, and 15 mm) coupled to the same silicon photomultiplier array. Each detector configuration has been experimentally characterized in terms of time, energy, and spatial resolution by scanning the crystal surface using a fan beam in steps of 0.25 mm. Regarding spatial resolution, the interaction position was estimated using a neural network technique. All resolutions except energy, which remains nearly constant at 17% for all cases, show better values for the 5-mm detector thickness. We have achieved spatial resolution values of full width at half of the maximum of 1.02 ± 0.10, 1.19 ± 0.13, 1.53 ± 0.17, and 2.33 ± 0.55 mm, for 5, 7.5, 10, and 15 mm blocks, respectively. The detector time resolution obtained was 275 ± 26, 291 ± 21, 344 ± 48, and 433 ± 45 ps, respectively, using the energy-weighted average method for the time stamps.