Siyang Liu

Siyang Liu

Auto-generated profile, based on publicly available information

Siyang Liu

School of Electrical Engineering, Southwest Jiaotong University, Chengdu, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2025 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
CCChunjian Cai
Chunjian Cai
JNJianglin Nie
Jianglin Nie
SJShijie Jiao
Shijie Jiao
SLSiyang Liu
Siyang Liu
SWShun Wang
Shun Wang
ZSZeliang Shu
Zeliang Shu
Single lithium-ion batteries typically have a lower voltage, so multiple batteries are often connected in series to achieve the required voltage level. To address the voltage imbalance caused by variations between individual cells, a fast active battery equalizer is proposed in this article. Compared to other active balancing circuits, the proposed balancing circuit utilizes a multiwinding transformer, requiring only two magnetic components, and each individual battery is controlled by a single switch, which reduces the circuit cost. Additionally, the proposed converter allows energy exchange between any positions of the battery string through the coordination of two balancing paths. The LC series resonant tank ensures that all switches operate under soft-switching conditions during the balancing process, thereby improving efficiency. Furthermore, a variable group control strategy is introduced to further increase the balancing current magnitude, enhancing the overall balancing speed of the converter. Finally, a 100 kHz resonant frequency, 24-cell voltage balancing prototype validates the effectiveness of the proposed balancing circuit.

30 November 2020 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Closed access
PDF file
MCMinwu Chen
Minwu Chen
SLSiyang Liu
Siyang Liu
NZNing Zhao
Ning Zhao
HFHaochun Fu
Haochun Fu
YLYabo Lv
Yabo Lv
Faults in electrified railway grounding grids can lead to significant surface potential rise, which threatens railway transportation and operation security. In order to efficiently diagnose the grounding status of the grounding grid and locate the fault location, this paper firstly presents the development of a mathematical model to reveal the earth surface potential distribution of grounding grids. Furthermore, a simulation model is built specifically for this study using CDEGS software to calculate the earth surface potential distribution of grounding grids under fault conditions. The simulation model has been used to validate the developed mathematical model by a comparison study. Finally, an intelligent algorithm based on grey incidence degree and fuzzy theory is proposed. This algorithm facilitates the fault condition diagnosis and the fault conductor position location. Using the fault condition data calculated by the simulation model, a few common grounding grids' fault conditions are diagnosed and located effectively by the proposed method. The results identify that the proposed method can ensure the safe operation of the traction substation.

12 February 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
SWShun Wang
Shun Wang
CTCen Tang
Cen Tang
SLSiyang Liu
Siyang Liu
XCXiaoqi Cao
Xiaoqi Cao
JNJianglin Nie
Jianglin Nie
ZSZeliang Shu
Zeliang Shu
Due to device losses and heat dissipation, single-phase rectifiers in high-speed railways are operated at low-switching frequencies. Harmonic resonance in the traction power supply substation is mostly caused by the low-frequency switching harmonics. In this article, a hybrid cascaded H-bridge multilevel rectifier is proposed to improve the overall performance by cascading a high-frequency switching cell. The added cell operates at full-range no-load with half the dc voltage of the low-frequency cell. The proposed asynchronous space vector pulsewidth modulation (SVPWM) provides equivalent switching frequencies in the low-voltage cell (LV $\_$ cell) while maintaining power frequency in the high-voltage cell. The limitation of no redundant vectors, the LV $\_$ cell's no-load operation, and the different voltage set values make voltage regulation challenging. An enhanced control strategy is proposed to maintain a stable voltage with wonderful dynamic performance. Simulation and experimental results show that better harmonic performance and lower power losses are achieved.

11 September 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YZYousong Zhou
Yousong Zhou
XXXifeng Xie
Xifeng Xie
JWJingchi Wu
Jingchi Wu
YDYuhao Deng
Yuhao Deng
SLSiyang Liu
Siyang Liu
ZSZeliang Shu
Zeliang Shu
Conventional space vector pulsewidth modulation (SVPWM) schemes for back-to-back cascaded H-bridge converters suffer from problems such as limited available sectors and the risk of capacitor short-circuit faults under phase difference conditions. To address these issues, a two-dimensional (2-D) SVPWM strategy based on bilateral voltage balancing is proposed in this article. The strategy optimizes the vector synthesis paths, expanding the boundary range of available sectors by 20% . It also ensures smooth transitions in port voltage levels, effectively reducing switching losses and voltage stress. Furthermore, the constraints between the modulation index and phase difference are clarified, providing a theoretical foundation for parameter design and stable operation. Simulation and experimental results demonstrate that the proposed method not only significantly extends the operational range, but also achieves steady-state performance while maintaining a fast dynamic response.

1 September 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
JWJingchi Wu
Jingchi Wu
LMLinghui Meng
Linghui Meng
YDYuhao Deng
Yuhao Deng
YZYoushong Zhou
Youshong Zhou
Jiangpeng YangJiangpeng Yang
Jiangpeng Yang
ZSZeliang Shu
Zeliang Shu
Achieving efficient power regulation without communication in wireless power transfer (WPT) systems remains a significant challenge, particularly under varying load and coupling conditions. This article proposes a dual-frequency dual-channel WPT system by introducing a third harmonic resonant channel alongside the fundamental power channel. The third harmonic current serves multiple roles: it enables communication-free synchronization via implicit phase feedback, contributes actively to power transfer, and extends the zero-voltage switching (ZVS) range of the primary-side inverter without increasing the switching frequency. A two-stage synchronous control strategy is developed to regulate power based solely on local measurements, avoiding complex sensing, parameters estimation, or digital modulation-demodulation. To control the overall size of the coupler, a compact coil design is adopted, while maintaining a competitive power density. The proposed system is validated on a 1.7 kW experimental platform. Results confirm the system’s wide ZVS range and its ability to maintain stable control without communication. The system achieves a peak efficiency of 94.39%, and remains above 93.5% when the output power exceeds 50% .

10 April 2020
Verified
Book Chapter
Closed access
PDF file
QDQian Deng
Qian Deng
RSRuizhi Shi
Ruizhi Shi
FCFuwei Chen
Fuwei Chen
JCJilei Chao
Jilei Chao
SLSiyang Liu
Siyang Liu