Aleksi Mattsson

Aleksi Mattsson

Auto-generated profile, based on publicly available information

Aleksi Mattsson

Department of Electrical Engineering, LUT University, Lappeenranta, Finland

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2017 in CIRED - Open Access Proceedings Journal
Verified
Journal Article
Open access
PNPasi Nuutinen
Pasi Nuutinen
TKTero Kaipia
Tero Kaipia
JKJanne Karppanen
Janne Karppanen
AMAleksi Mattsson
Aleksi Mattsson
ALAndrey Lana
Andrey Lana
THTomi Hakala
Tomi Hakala
When a low-voltage (LV) DC distribution system installation is realised in a public power distribution network, an extensive specification is required to ensure electrical and equipment safety and compatibility between the existing grids and customer-end installations. The goal of the study is to give to a reader an understanding what is required for safe and reliable operation of the LVDC distribution in an actual distribution environment. The study discusses the mechanical and electro-technical aspects of the pilot installation. The focus is on the common system and power electronics specifications.

1 January 2026 in IEEE Access
Verified
Journal Article
Open access
HCHüseyin Tayyer CANSEVEN
Hüseyin Tayyer CANSEVEN
DUDeepak Upadhyay
Deepak Upadhyay
SDSaeid Deliri
Saeid Deliri
IPIlya Petrov
Ilya Petrov
AMAleksi Mattsson
Aleksi Mattsson
JPJuha Pyrhönen
Juha Pyrhönen

25 March 2024
Verified
Conference Paper
Closed access
JKJuhamatti Korhonen
Juhamatti Korhonen
LTLauri Tuimala
Lauri Tuimala
HTHenri Tulla
Henri Tulla
AMAleksi Mattsson
Aleksi Mattsson
PSPertti Silventoinen
Pertti Silventoinen
Multilevel inverter topologies are known for their inherent ability to produce high power quality, yet this can only be achieved with proper control and modulation. In this paper, an improved modulation for a nine-level single-phase inverter called Packed E-Cell Converter is proposed. Previously the topology has been found to suffer from adverse commutation effects during the dead times between the switching operations. This is due to the lack of appropriate freewheeling current paths for certain commutation loops. The proposed modulation strategy allows the elimination of the most severe voltage spikes with an amplitude up to DC link voltage at the zero-crossings of the modulated output voltage. The proposed modulation is simulated and the superior performance is demonstrated in comparison to the original pulse-width modulation.

20 April 2026 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Open access
DUDeepak Upadhyay
Deepak Upadhyay
HMHouyi Ma
Houyi Ma
SSShruti Singh
Shruti Singh
IPIlya Petrov
Ilya Petrov
AMAleksi Mattsson
Aleksi Mattsson
JPJuha Pyrhönen
Juha Pyrhönen
This article presents a comprehensive investigation into the transient inductance of a 27 kW, 100 000 rpm high-speed axially laminated anisotropic synchronous reluctance machine (ALASynRM). While traditional transversally laminated rotor synchronous reluctance machines exhibit significant angular dependence of transient inductance, this study reveals and theoretically quantifies the spatial invariance of this parameter in solid-rotor ALASynRMs due to high-frequency eddy current shielding in the conductive laminate layers. A refined finite element method (FEM) modeling approach is proposed that integrates 3-D end-winding leakage effects and material resistivity sensitivity to overcome the limitations of standard 2-D magnetic analysis. This modeling framework is rigorously validated through experimental measurements on a high-speed prototype, demonstrating a maximum deviation of 6.3% and an average deviation of only 2.5%. The article establishes a novel design-oriented theoretical framework that links the machine’s transient electromagnetic behavior directly to power converter performance. By quantifying the impact of transient inductance on current ripple and total harmonic distortion (THD), a systematic methodology for selecting optimal switching frequencies and DC-link voltages is provided. This approach ensures high-performance operation while accounting for the inherent computational constraints of high-speed motor controllers.

26 November 2024
Verified
Conference Paper
Closed access
DLDong Liu
Dong Liu
AMAleksi Mattsson
Aleksi Mattsson
JKJuhamatti Korhonen
Juhamatti Korhonen
Lassi AarniovuoriLassi Aarniovuori
Lassi Aarniovuori
HJHeikki Järvisalo
Heikki Järvisalo
PSPertti Silventoinen
Pertti Silventoinen
Isolated full-bridge DC-DC converters are being extensively used when power levels of over 100 kWare needed for fast charging of electric vehicles. This paper analyses the efficiencies of two popular unidirectional converter topologies, namely phase-shift full-bridge converter and LLC converter that utilize silicon carbide semiconductors. Efficiencies of the converters at partial load and various input-output voltage levels are evaluated by by simulations in Plexim PLECS. The results show that the designed phase-shift full-bridge converter has higher efficiency than the LLC converter when high boost ratio is required, whereas the LLC converter has higher efficiency near the nominal operating voltages.