29 October 2020 in Journal of Lightwave Technology
An all-fiber target-type flow velocity sensor was proposed and experimentally demonstrated based on the Michelson interferometer (MI). Commercially available single mode fiber (SMF) was used as the basic material and assisted with the arc discharge technology the sensing structure can be fabricated with high efficiency and quality. The designed sensor structure contains a peanut-shape structure that acts as a coupler/splitter, a SMF that acts as a cantilever beam, and a spherical tip that acts as a target, which all can be realized by arc discharge technology. The simulation verifies the effectiveness and high sensitivity of the peanut-shape structure for flow velocity measurement, and the key parameters were optimized. A comprehensive experiment was carried out on the flow velocity experiment. The experimental results show that the sensor has high sensitivity of -1.30 nm/(cm/s), precision of 1.4% and detection limit (DL) of 0.015 cm/s in the range of 0-11 cm/s. In addition, the temperature sensitivity is 58.5 pm/°C and the flow velocity-temperature cross-sensitivity is less than 0.05 (cm/s)/°C. Such a high-sensitivity, low cross-sensitivity and low-cost sensor, is very promising for the applications on high-precision liquid and abysmal sea flow velocity measurement.
6 December 2023 in Journal of Lightwave Technology
A novel torsion sensor based on modal interference and the Lyot filter by utilizing the exciting mode in the single eccentric hole-assisted dual-core fiber (SEHADCF). Based on the interaction between the polarization functional modes and the mode of the suspended core, the phenomena of the interference resonance enhancement and the enhanced Vernier are realized by only adjusting the polarization of the incident light. The sensitivity of the proposed sensor reaches 171.97 dB/rad and 58.87 nm/rad, respectively. Furthermore, the vector property of the polarization state makes it possible to identify both the direction and the degree of the twist applied on the structure. Due to the selective amplification only applied on the parameter of the vector, the crosstalk from other mechanical parameters, including curvature and strain, is decreased significantly. The crosstalk of the strain is low to 7.474 ×10 -7 rad/με. The proposed scheme of the sensor provides a new perspective of regulating both the polarization state and the fiber mode in the sensing field.
7 February 2022 in Journal of Lightwave Technology
We propose an ultra-compact full-angle-range direction-distinguishable tilt sensor based on a polymer column working as a Fabry–Perot (FP) microcavity fixed between two sections of single-mode fibers (SMFs). The directional tilt angle from −90 deg to +90 deg can be demodulated by monitoring the wavelength shift of interference fringe, based on the deformation of the polymer column under the effect of the gravity force. The sensitivity of the sensor can be adjusted by changing the shape and size of the polymer column that is fabricated by the single beam illumination with high efficiency and low cost. The sensor can satisfy the engineering requirements owing to its small size, flexible structure, cost-effective performance, large measurement range, and direction-distinguishable ability.
27 February 2025 in Journal of Lightwave Technology
A vector bending sensor based on low-cost single-channel measurement and a highly reliable three-peak reconstruction algorithm is proposed. The sensor consists of single-mode fiber (SMF), multimode fiber (MMF) and two side-hole fibers (SHFs) of different lengths, with a 90° offset angle. The lengths of MMF and SHFs are 375 μm, 400 μm and 300 μm. Fresnel reflection occurs at the interface due to the difference in refractive index (RI) between air and fiber cladding, creating three reflective surfaces. Three Fabry-Perot interferometers (FPIs) with different optical path difference (OPD) are constructed using only two SHFs. A low-cost single-channel measurement method is employed to simultaneously demodulate the interference signals from the three FPIs. When bending is applied to the sensor, each FPI exhibits different strain variation. Experimental results show that the bending responses of FPIs are highly dependent on the bending directions, and each of them exhibits its maximum sensitivity at a different bending direction. The maximum positive sensitivities of FPIs are 155.11 pm/m-1 (0°), 210.45 pm/m-1 (225°), and 91.78 pm/m-1 (255°), respectively. Thus, the three FPIs are located at different spatial positions, making them fitted for vector bending sensing. In addition, the application of the three-peak reconstruction algorithm significantly enhances the stability and reliability of the curvature and bending direction reconstruction.
22 July 2024 in IEEE Sensors Journal
An ultra-compact temperature-compensated all-fiber ultraviolet sensor based on CdZnSe/ZnSe/ZnS quantum dots sealed in liquid-cavity is proposed. The ultraviolet-sensitive region is integrated inside the fiber to avoid interference from external media, and high fluorescence conversion efficiency and ultra-compact structure are achieved due to the high fluorescence quantum efficiency and excellent luminescence stability of CdZnSe/ZnSe/ZnS quantum dots solution. The temperature crosstalk problem of semiconductor materials applied to sensors is solved in this single structure by monitoring of peak wavelength and intensity of fluorescence spectra simultaneously to achieve the temperature compensation function of the sensor. The results show linear dependence of UV sensitivity on temperature which is able to be demodulated through peak wavelength individually. In addition, the quantum dots sealed in liquid-cavity protected by hollow core fiber can resist corrosion, high pressure, and electromagnetic interference, providing a new idea for UV detection in harsh environments.
25 June 2025 in Journal of Lightwave Technology
This study presents an optical microforce fiber sensor leveraging the harmonic vernier effect (HVE) through a Fabry-Perot interferometer (FPI) architecture. The sensor comprises a precisely aligned thin fiber (TF) nested within a section of hollow-core fiber (HCF), with UV-curable adhesive providing both structural fixation and force transduction. Unlike conventional vernier effect (CVE) configurations requiring high fabrication precision, the proposed HVE-based design demonstrates relaxed structural tolerances while maintaining superior performance metrics. The sensor achieves exceptional microforce sensitivity of 11.7 pm/μN through optimized cavity length modulation, enabling first-order harmonic Vernier amplification. Advanced signal processing through inner envelope intersection tracking produces a high measurement resolution of 16.41 μN, with temperature cross-sensitivity minimized to 7.85 pm/°C. Experimental validation confirms the robust performance of the sensor in practical microforce measurement scenarios, offering significant advantages in fabrication simplicity, stable measurement, and high repeatability compared to existing optical microforce sensors.