Pierre Mougenot

Pierre Mougenot

Auto-generated profile, based on publicly available information

Pierre Mougenot

CESTER, Technical University of Cluj-Napoca

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 February 2026 in Robotics
Verified
Journal Article
Open access
PDF file
Calin VaidaCalin Vaida
Calin Vaida
IZIonut Marian Zima
Ionut Marian Zima
Florin GraurFlorin Graur
Florin Graur
BGBogdan Gherman
Bogdan Gherman
VBVasile Nicolae Bulbucan
Vasile Nicolae Bulbucan
Doina PislaDoina Pisla
Doina Pisla
Background: Flexible surgical instruments for Robot-Assisted Minimally Invasive Surgery (RAMIS) face a critical limitation: the inability to rotate the distal head while the instrument is in a bent configuration, which restricts the maneuverability in narrow surgical workspaces. Methods: This paper presents a novel 4-degree-of-freedom (DOF) flexible laparoscopic instrument with a 10 mm diameter, incorporating a 3D-printed flexible element. The design enables independent bending (0–90°), continuous distal head rotation (360°), gripper actuation (0–60°), and rod rotation (180°). A constant-curvature kinematic model was developed. The instrument was manufactured using PolyJet 3D printing technology and integrated with the ATHENA parallel robot for proof-of-concept experimental validation. Results: Experimental tests demonstrated successful independent 360° distal head rotation across the full bending range (0–90°), validated through simulated surgical procedures including stomach retraction. Quantitative characterization using optical motion capture revealed a maximum angular deflection of 79.85° at 670 g applied load, with tip displacements of 74.95 mm (X) and 91.18 mm (Y). The measured grasping force was approximately 2 N, tip position repeatability was ±2.86 mm, and fatigue testing demonstrated no degradation after 500 bending cycles, confirmed by digital microscope inspection. The instrument performed multiple manipulation tasks, including elastic band transfer, wire path navigation, spring manipulation, and tissue grasping. Conclusions: The proposed instrument addresses a significant white spot in surgical robotics by adding an additional functional capability enabling grasper reorientation without repositioning the entire instrument.

4 February 2026
Verified
Book Chapter
Closed access
APAlexandru-Vasile Vasile Pusca
Alexandru-Vasile Vasile Pusca
Florin CovaciuFlorin Covaciu
Florin Covaciu
ABAlin Burz
Alin Burz
AHAlin Horsia
Alin Horsia
PMPierre Mougenot
Pierre Mougenot
Doina PislaDoina Pisla
Doina Pisla

14 September 2026
Verified
Book Chapter
Closed access
PDF file
Doina PislaDoina Pisla
Doina Pisla
Calin VaidaCalin Vaida
Calin Vaida
MMMarius Miclaus
Marius Miclaus
BGBogdan Gherman
Bogdan Gherman
DHDaniel Horvath
Daniel Horvath
PTPaul Tucan
Paul Tucan