Pooja Devi

Pooja Devi

Auto-generated profile, based on publicly available information

Pooja Devi

Institute of Physics of the Czech Academy of Sciences, 18200 Prague, Czech Republic

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2025 in Physics of Plasmas
Verified
Journal Article
Open access
SSSushil Kumar Singh
Sushil Kumar Singh
MKMichal Krupka
Michal Krupka
Josef KrásaJosef Krása
Josef Krása
SAShubham Agarwal
Shubham Agarwal
PDP. Devi
P. Devi
Libor JuhaLibor Juha
Libor Juha
We experimentally demonstrate the generation of quasi-monoenergetic electron bunch at the end of the electron energy distribution. The experiment was conducted at the Prague Asterix Laser System where iodine laser supplies laser energy up to 600 J at the fundamental wavelength of 1.315 μm with a pulse duration of 350 ps. The thickness of different target materials (Cu, Sn, Ta, Pb) was varied between 10 and 25 μm. The energy spectrum of electrons was measured using an array of electron spectrometers at different angular directions with respect to the laser axis. Three frame femtosecond interferometry driven by a Ti:Sa laser was implemented to scan the changes in electron density during plasma ignition by the iodine laser. The experimental results indicate the generation of well-defined quasi-monoenergetic peaks in the electron energy distribution. The energy range of the measured quasi-monoenergetic peaks lies between 0.6 and 1.5 MeV; however, the energy spread of the distribution varies between 4% and 12%. These features were observed consistently in the electron spectrum and illustrate the quasi-monoenergetic electron beam generation by interaction of a sub-nanosecond laser beam with plasma. In addition, a comparison of electron spectra from spectrometers located in opposite directions relative to the position of the laser focus indicates the splitting of the electron cloud into plasma blocks during the acceleration of hot electrons by Coulomb repulsion. These findings can be applicable in fast electron beam-driven radiation sources, electromagnetic pulse generation, charge particle acceleration, and inertial fusion studies.

1 July 2025 in Matter and Radiation at Extremes
Verified
Journal Article
Open access
Gabriele CristoforettiGabriele Cristoforetti
Gabriele Cristoforetti
EHE. Hume
E. Hume
SAShubham Agarwal
Shubham Agarwal
DBDimitri Dino Batani
Dimitri Dino Batani
MCM. Cervenak
M. Cervenak
Leonida Antonio GizziLeonida Antonio Gizzi
Leonida Antonio Gizzi
Recent experiments at the National Ignition Facility and theoretical modeling suggest that side stimulated Raman scattering (SSRS) instability could reduce laser–plasma coupling and generate considerable fluxes of suprathermal hot electrons under interaction conditions envisaged for direct-drive schemes for inertial confinement fusion. Nonetheless, SSRS remains to date one of the least understood parametric instabilities. Here, we report the first angularly and spectrally resolved measurements of scattered light at laser intensities relevant for the shock ignition scheme (I ∼ 1016 W/cm2), showing significant SSRS growth in the direction perpendicular to the laser polarization. Modification of the focal spot shape and orientation, obtained by using two different random phase plates, and of the density gradient of the plasma, by utilizing exploding foil targets of different thicknesses, clearly reveals a different dependence of backward SRS (BSRS) and SSRS on experimental parameters. While convective BSRS scales with plasma density scale length, as expected by linear theory, the growth of SSRS depends on the spot extension in the direction perpendicular to laser polarization. Our analysis therefore demonstrates that under current experimental conditions, with density scale lengths Ln ≈ 60–120 μm and spot sizes FWHM ≈ 40–100 μm, SSRS is limited by laser beam size rather than by the density scale length of the plasma.

1 September 2026 in Review of Scientific Instruments
Verified
Journal Article
Closed access
SAShubham Agarwal
Shubham Agarwal
SSSushil Kumar Singh
Sushil Kumar Singh
PDP. Devi
P. Devi
MKMichal Krupka
Michal Krupka
AGA. Laso Garcia
A. Laso Garcia
Libor JuhaLibor Juha
Libor Juha
Real-time online diagnostics are essential for high-repetition-rate laser–plasma experiments, offering clear advantages over traditional, manually exchanged offline detectors, such as imaging plates, by eliminating the shot-to-shot processing time. Scintillator based detectors are widely used to measure bremsstrahlung radiation from laser–matter interactions, enabling the characterization of hot-electron distributions. In this study, we present absolute calibration of a lutetium–yttrium oxyorthosilicate crystal-based multilayer scintillator stack spectrometer performed at the MT25 microtron facility in Prague. Bremsstrahlung radiation was generated by irradiating a tungsten converter with monoenergetic electron beams in the energy range between 5 MeV and 22 MeV. The response of the individual crystal was measured and compared with the energy deposition calculated using the Fluktuierende Kaskade (FLUKA) Monte Carlo simulation. A linear correlation between signal response and energy deposition was obtained for all crystals within the experimental uncertainty, confirming detector linearity with the calibration factor 0.014 ± 0.002 ADU/keV (where ADU denotes the analog-to-digital unit). This calibration enables quantitative, real-time measurement of bremsstrahlung spectra and is valuable for particle acceleration, high-intensity laser–plasma experiments, laboratory astrophysics, warm dense matter, and inertial confinement fusion studies.

1 February 2026 in Review of Scientific Instruments
Verified
Journal Article
Open access
ARAngelo Maria Raso
Angelo Maria Raso
EDEdoardo Domenicone
Edoardo Domenicone
GPGiada Petringa
Giada Petringa
FCFabrizio Consoli
Fabrizio Consoli
FAFarmesk Abubaker
Farmesk Abubaker
Claudio VeronaClaudio Verona
Claudio Verona
Recent advances in ion diagnostics for laser-induced plasma experiments have improved system design and data analysis. Measuring charged particle emissions from laser-irradiated targets provides valuable insights into laser–matter interactions. Among real-time diagnostics, Time-of-Flight (TOF) detectors are reliable systems for analyzing particle beam properties such as kinetic energy and shot-to-shot reproducibility. Diamond-based detectors are ideal for TOF measurements due to their fast response time, radiation hardness, and low leakage current. However, TOF detectors lack particle discrimination. To overcome this, a Multi Filter Diamond Array (MFDA) was developed using six nominally identical single crystal diamond detectors paired with aluminum foils of different thicknesses to exploit particle stopping power differences. The MFDA was tested at the Prague Asterix Laser System during an experimental campaign in the framework of the FUSION project, and data analysis was performed. A cross-validation with other diagnostics, including a Thomson Parabola Spectrometer and CR-39 detectors, is also presented.

7 April 2026 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Open access
JCJakub Cikhardt
Jakub Cikhardt
Josef KrásaJosef Krása
Josef Krása
SAShubham Agarwal
Shubham Agarwal
MAMassimo Alonzo
Massimo Alonzo
PBPhilip Bradford
Philip Bradford
Libor JuhaLibor Juha
Libor Juha
In this contribution, we present the results of a long-term study on radiofrequency and microwave electromagnetic pulse (EMP) emission, a phenomenon that is still not satisfactorily explained, performed at the PALS iodine laser system (1315 nm, 0.3 ns, up to 700 J on target). Using a comprehensive set of broadband diagnostics, including double ridged horn antennas, target current probe, along with special low-loss cables and oscilloscopes with sampling rates up to 100 GS/s, we observed an unprecedentedly broad EMP spectrum with frequencies significantly exceeding 10 GHz. Moreover, scaling experiments revealed a dependence of the spectral shape and its central frequency on the laser intensity, and this was further correlated with electron emission. This dependence indicates that in addition to the well-known influence of the eigenfrequencies of the experimental hardware (e.g., target, stalk, and chamber), processes associated with the expanding plasma can also play a dominant role, as demonstrated in this study. We believe that these new findings will not only contribute to EMP mitigation and deepen our understanding of fundamental physics, but also support high-tech applications such as EMP hardening, biomedical research, and defense technologies.