Shenglan Ma

Shenglan Ma

Auto-generated profile, based on publicly available information

Shenglan Ma

Fujian Provincial Key Laboratory of Advanced Technology and Informatization in Civil Engineering Fujian University of Technology Fuzhou China

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018 in Journal of Aerospace Engineering
Verified
Journal Article
Closed access
XFXingyu Fan
Xingyu Fan
Jun LiJun Li
Jun Li
HHHong Hao
Hong Hao
SMShenglan Ma
Shenglan Ma
This paper proposes a structural damage identification approach based on model updating with electromechanical impedance sensitivity and the sparse regularization technique to identify the location and severity of minor damage in structures. The sensitivities of the resonance frequency shifts in the impedance responses with respect to the stiffness parameters of the host structure are calculated and used to identify the damage with a small number of resonance frequency shifts. Numerical verifications on a single lead zirconate titanate (PZT) transducer patch and a PZT on a narrow aluminum plate structure are conducted to validate the finite-element modeling technique to calculate the impedance. The effectiveness and performance of the proposed structural damage identification approach are demonstrated with numerical simulations on an aluminum plate model attached to a PZT transducer patch. The initial finite-element model and a limited number of resonance frequency shifts in the impedance responses are used for the identification. Sparse regularization, namely, the l1 regularization technique, is used for solving the inverse problem. Single and multiple damage scenarios are considered. The effects of noise in the measured impedance signals and the number of available frequency shifts on the performance of the proposed damage identification approach are investigated. The results demonstrate the performance and robustness of the proposed approach.

23 November 2018 in Sensors
Verified
Journal Article
Open access
PDF file
Sheng ShenSheng Shen
Sheng Shen
YWYao Wang
Yao Wang
SMSheng-Lan Ma
Sheng-Lan Ma
DHDi Huang
Di Huang
ZWZhi-Hong Wu
Zhi-Hong Wu
XGXiao Guo
Xiao Guo
Prestress loss evaluation in prestressed strands is essential for prestressed structures. However, the sensors installed outside the duct can only measure the total prestress loss. The sensors attached on strands inside the duct also have several problems, such as inadequate durability in an aggressive environment and vulnerability to damage during tensioning. This paper proposes a new installation method for long-gauge fiber Bragg grating (LFBG) sensors to prevent accidental damage. Then the itemized prestress losses were determined in each stage of the pre-tensioning and post-tensioning according to the LFBG measurements. We verified the applicability of the LFBG sensors for prestress monitoring and the accuracy of the proposed prestress loss calculation method during pre-tensioning and post-tensioning. In the pre-tensioning case, the calculated prestress losses had less deviation from the true losses than those obtained from foil-strain gauges, and the durability of the LFBG sensors was better than foil-strain gauges, whereas in post-tensioning case, the calculated prestress losses were close to those derived from theoretical predictions. Finally, we monitored prestress variation in the strand for 90 days. The itemized prestress losses at each stages of post-tensioning were obtained by the proposed calculation method to show the prospect of the LFBG sensors in practical evaluation.

23 December 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CWChen Wu
Chen Wu
CYChao Yang
Chao Yang
SMShenglan Ma
Shenglan Ma
XXXiaoliang Xu
Xiaoliang Xu
Steel sleeve grouting connections are widely used in prefabricated concrete structures. It is well known that insufficient grouting increases the chance of structural failure. As such, it is critical to monitor the density and compactness of grouting sleeve during the construction process, which however remains significant challenges as it is deeply buried in the beam and column. In this study, a lead zirconate titanate (PZT)-based sleeve grouting compactness detection method was systematically investigated. Five grouting sleeves samples with different degrees of compactness were prepared and four PZT transducers were surface-bonded on opposite sides of the outer wall of each sleeve. Two acts as actuators to generate stress wave signals, and the other two operate as sensors to receive the signals. The wavelet packet energy and Hilbert–Huang transform methods were applied to process the stress wave signals, and with the chosen characteristic parameters, the correction model of the grouting compactness was established. Experimental results show that the wavelet packet total energy values and the Hilbert energy peak values are related to the grouting compactness, indicating the feasibility of using PZT sensors to detect the compactness of grouting sleeves.

1 March 2006 in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
Verified
Journal Article
Closed access
LZL.B. Zhou
L.B. Zhou
WLW.J. Li
W.J. Li
SMS. Ma
S. Ma
XDX.C. Dong
X.C. Dong
LYL.X. Yu
L.X. Yu
QGQ.X. Gao
Q.X. Gao

26 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
CWChen Wu
Chen Wu
HXHong Xiang
Hong Xiang
SJShaofei Jiang
Shaofei Jiang
SMShenglan Ma
Shenglan Ma
The uniaxial piezoelectric sensor was developed to overcome the problem of reflecting the output charge of the piezoelectric element as a combination of vectors in the three stress directions. The work performance of the uniaxial piezoelectric sensor under varying load patterns and load rates was investigated. The sensor was embedded in concrete to monitor stress, and its elastic modulus was used as the intermediate bridge to establish the correlation between the embedded sensor and the external sensor. Furthermore, a correction factor for the charge transformation strain was suggested to overcome the mismatching of the sensor’s medium and the concrete. Considering related circumstances, a new stress monitoring method based on a uniaxial piezoelectric sensor was proposed, which can achieve stress whole-process monitoring in concrete and confining stress monitoring in the reinforced concrete column. The results reveal that through the proposed method, the output charge curve of the sensor has a substantial overlap with the stress waveform and high fitting linearity. The work performance of the sensor was stable, and its sensitivity was not affected by loading rate and load pattern. The sensor was embedded in concrete and can coordinate with the concrete deformation. The correction factor of strain obtained by the sensor embedded in concrete was 1.07. The relationship between the charge produced by the embedded sensor and its external calibration sensitivity may be used to implement the whole process of stress monitoring in concrete.

16 August 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SJShaofei Jiang
Shaofei Jiang
SLShenghang Lian
Shenghang Lian
JZJian Zhao
Jian Zhao
XLXiang Li
Xiang Li
SMShenglan Ma
Shenglan Ma
A variety of forms of connection in precast reinforced concrete (PC) have been proposed, but the impact of the connection forms on the shear wall remains to be studied. In this paper, through quasi-static experiments and numerical simulations, the influences of a new form of bolted connection on the mechanical behaviors of the PC shear wall are investigated. The results show that the strain of the connector is less than the yield strain and the failure does not occur in the connector; the mechanical behaviors of this connection form of the PC shear wall are equivalent to those of the cast-in-place reinforced concrete (RC) shear wall. Meanwhile, reasonable suggestions are put forward for the design of the connector from the pretightening force, bolt number, and axial compression ratio. This implies that this form of bolted connection has little influence on the mechanical behaviors of the PC shear wall and design suggestions can be used in practical projects.