21 December 2020 in Nuclear Fusion
Future fusion reactors require a safe, steady state divertor operation. The required detached operation is, in tokamaks with metal walls, usually achieved by seeding of impurities, such as nitrogen. With strong seeding levels, the dominant radiation is emitted from a small, poloidally localized volume inside the confined region, in the vicinity of the X-point. The location of the radiating volume is observed to vary relative to the X-point depending on seeding and power levels, i.e. depending on the degree of detachment. At the ASDEX Upgrade tokamak, the position of the radiator relative to the X-point can be controlled in real time by a modulation of the nitrogen puff level. At a certain height of the radiator above the X-point, an ELM-suppressed regime is observed with minimal reduction of confinement. While the control of the X-point radiator already allows operation in full detachment at a dissipated power fraction of around 95 %, which is required for a future reactor and was previously never achieved in a controlled way, such an ELM-suppressed regime additionally eliminates the challenge of the transient, intolerably high heat fluxes by ELMs. Both requirements are met in the presented regime while maintaining a high energy confinement at high density.
13 December 2021 in Plasma Physics and Controlled Fusion
The favorable confinement properties of negative-triangularity (NT) tokamak configurations were discovered in the TCV tokamak in the late 1990s and were documented over the two following decades, through investigations of predominantly electron-heated plasmas in limited topologies. The most recent experimental campaign in TCV has marked a leap forward, characterized by the development of a variety of diverted NT shapes that are robustly stable with basic Ohmic heating. The application of auxiliary heating, directed now at both electrons and ions (using electron-cyclotron resonance heating as well as neutral-beam injection), has enabled the achievement of record performances for L-mode plasmas, with normalized β values reaching 2.8 transiently (as well as 2 in steady state, but reverting to a limited configuration) and with comparable ion and electron temperatures. The systematic confinement enhancement with NT is confirmed in these experiments. The L-mode existence space is broader than at positive triangularity, with only sporadic transitions to H-mode observed up to 1.4 MW heating power regardless of the magnetic-field-gradient direction relative to the X-point. These experiments are planned to be continued with even higher power following a heating-source upgrade.
17 February 2021 in Nature Communications
In magnetic confinement thermonuclear fusion the exhaust of heat and particles from the core remains a major challenge. Heat and particles leaving the core are transported via open magnetic field lines to a region of the reactor wall, called the divertor. Unabated, the heat and particle fluxes may become intolerable and damage the divertor. Controlled ‘plasma detachment’, a regime characterized by both a large reduction in plasma pressure and temperature at the divertor target, is required to reduce fluxes onto the divertor. Here we report a systematic approach towards achieving this critical need through feedback control of impurity emission front locations and its experimental demonstration. Our approach comprises a combination of real-time plasma diagnostic utilization, dynamic characterization of the plasma in proximity to the divertor, and efficient, reliable offline feedback controller design.
1 May 2018 in Review of Scientific Instruments
This paper presents the current wall-embedded Langmuir probe system installed on the Tokamak à Configuration Variable (TCV), as well as the analysis tool chain used to interpret the current-voltage characteristic obtained when the probes are operated in swept-bias conditions. The analysis is based on a four-parameter fit combined with a minimum temperature approach. In order to reduce the effect of plasma fluctuations and measurement noise, several current-voltage characteristics are usually averaged before proceeding to the fitting. The impact of this procedure on the results is investigated, as well as the possible role of finite resistances in the circuitry, which could lead to an overestimation of the temperature. We study the application of the procedure in a specific regime, the plasma detachment, where results from other diagnostics indicate that the electron temperature derived from the Langmuir probes might be overestimated. To address this issue, we explore other fitting models and, in particular, an extension of the asymmetric double probe fit, which features effects of sheath expansion. We show that these models yield lower temperatures (up to approximately 60%) than the standard analysis in detached conditions, particularly for a temperature peak observed near the plasma strike point, but a discrepancy with other measurements remains. We explore a possible explanation for this observation, the presence of a fast electron population, and assess how robust the different methods are in such conditions.
30 October 2019 in Nuclear Fusion
17 October 2019 in Nuclear Fusion