Ronald Mooiweer

Ronald Mooiweer

Auto-generated profile, based on publicly available information

Ronald Mooiweer

Biomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences King's College London London UK

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 December 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
RMRonald Mooiweer
Ronald Mooiweer
RNRadhouene Neji
Radhouene Neji
SMSarah McElroy
Sarah McElroy
MNMuhummad Sohaib Nazir
Muhummad Sohaib Nazir
RRReza Razavi
Reza Razavi
SRSébastien Roujol
Sébastien Roujol
Purpose: To develop and evaluate a fast respiratory navigator (fastNAV) for cardiac MR perfusion imaging with subject‐specific prospective slice tracking.Methods: A fastNAV was developed for dynamic contrast‐enhanced cardiac MR perfusion imaging by combining spatially nonselective saturation with slice‐selective tip‐up and slice‐selective excitation pulses. The excitation slice was angulated from the tip‐up slice in the transverse plane to overlap only in the right hemidiaphragm for suppression of signal outside the right hemidiaphragm. A calibration scan was developed to enable the estimation of subject‐specific tracking factors. Perfusion imaging using subject‐specific fastNAV‐based slice tracking was then compared to a conventional sequence (ie, without slice tracking) in 10 patients under free‐breathing conditions. Respiratory motion in perfusion images was quantitatively assessed by measuring the average overlap of the left ventricle across images (avDice, 0:no overlap/1:perfect overlap) and the average displacement of the center of mass of the left ventricle (avCoM). Image quality was subjectively assessed using a 4‐point scoring system (1: poor, 4: excellent).Results: The fastNAV calibration was successfully performed in all subjects (average tracking factor of 0.46 ± 0.13, R = 0.94 ± 0.03). Prospective motion correction using fastNAV led to higher avDice (0.94 ± 0.02 vs. 0.90 ± 0.03, P < .001) and reduced avCoM (4.03 ± 0.84 vs. 5.22 ± 1.22, P < .001). There were no statistically significant differences between the 2 sequences in terms of image quality (both sequences: median = 3 and interquartile range = 3‐4, P = 1).Conclusion: fastNAV enables fast and robust right hemidiaphragm motion tracking in a perfusion sequence. In combination with subject‐specific slice tracking, fastNAV reduces the effect of respiratory motion during free‐breathing cardiac MR perfusion imaging.

7 September 2023 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
RSRohini Vidya Shankar
Rohini Vidya Shankar
LHLi Huang
Li Huang
RNRadhouene Neji
Radhouene Neji
GKGrzegorz Kowalik
Grzegorz Kowalik
ANAlexander Paul Neofytou
Alexander Paul Neofytou
SRSébastien Roujol
Sébastien Roujol
Purpose: MR‐guided cardiac catheterization procedures currently use passive tracking approaches to follow a gadolinium‐filled catheter balloon during catheter navigation. This requires frequent manual tracking and repositioning of the imaging slice during navigation. In this study, a novel framework for automatic real‐time catheter tracking during MR‐guided cardiac catheterization is presented.Methods: The proposed framework includes two imaging modes (Calibration and Runtime). The sequence starts in Calibration mode, in which the 3D catheter coordinates are determined using a stack of 10–20 contiguous saturated slices combined with real‐time image processing. The sequence then automatically switches to Runtime mode, where three contiguous slices (acquired with partial saturation), initially centered on the catheter balloon using the Calibration feedback, are acquired continuously. The 3D catheter balloon coordinates are estimated in real time from each Runtime slice stack using image processing. Each Runtime stack is repositioned to maintain the catheter balloon in the central slice based on the prior Runtime feedback. The sequence switches back to Calibration mode if the catheter is not detected. This framework was evaluated in a heart phantom and 3 patients undergoing MR‐guided cardiac catheterization. Catheter detection accuracy and rate of catheter visibility were evaluated.Results: The automatic detection accuracy for the catheter balloon during the Calibration/Runtime mode was 100%/95% in phantom and 100%/97 ± 3% in patients. During Runtime, the catheter was visible in 82% and 98 ± 2% of the real‐time measurements in the phantom and patients, respectively.Conclusion: The proposed framework enabled real‐time continuous automatic tracking of a gadolinium‐filled catheter balloon during MR‐guided cardiac catheterization.

10 February 2023 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
ANAlexander Paul Neofytou
Alexander Paul Neofytou
RNRadhouene Neji
Radhouene Neji
GKGrzegorz Tomasz Kowalik
Grzegorz Tomasz Kowalik
RMRonald Mooiweer
Ronald Mooiweer
JWJames Wong
James Wong
SRSébastien Roujol
Sébastien Roujol
Purpose: To develop a motion‐robust reconstruction technique for free‐breathing cine imaging with multiple averages.Method: Retrospective motion correction through multiple average k‐space data elimination (REMAKE) was developed using iterative removal of k‐space segments (from individual k‐space samples) that contribute most to motion corruption while combining any remaining segments across multiple signal averages. A variant of REMAKE, termed REMAKE+, was developed to address any losses in SNR due to k‐space information removal. With REMAKE+, multiple reconstructions using different initial conditions were performed, co‐registered, and averaged. Both techniques were validated against clinical “standard” signal averaging reconstruction in a static phantom (with simulated motion) and 15 patients undergoing free‐breathing cine imaging with multiple averages. Quantitative analysis of myocardial sharpness, blood/myocardial SNR, myocardial‐blood contrast‐to‐noise ratio (CNR), as well as subjective assessment of image quality and rate of diagnostic quality images were performed.Results: In phantom, motion artifacts using “standard” (RMS error [RMSE]: 2.2 ± 0.5) were substantially reduced using REMAKE/REMAKE+ (RMSE: 1.5 ± 0.4/1.0 ± 0.4, p < 0.01). In patients, REMAKE/REMAKE+ led to higher myocardial sharpness (0.79 ± 0.09/0.79 ± 0.1 vs. 0.74 ± 0.12 for “standard”, p = 0.004/0.04), higher image quality (1.8 ± 0.2/1.9 ± 0.2 vs. 1.6 ± 0.4 for “standard”, p = 0.02/0.008), and a higher rate of diagnostic quality images (99%/100% vs. 94% for “standard”). Blood/myocardial SNR for “standard” (94 ± 30/33 ± 10) was higher vs. REMAKE (80 ± 25/28 ± 8, p = 0.002/0.005) and tended to be lower vs. REMAKE+ (105 ± 33/36 ± 12, p = 0.02/0.06). Myocardial‐blood CNR for “standard” (61 ± 22) was higher vs. REMAKE (53 ± 19, p = 0.003) and lower vs. REMAKE+ (69 ± 24, p = 0.007).Conclusions: Compared to “standard” signal averaging reconstruction, REMAKE and REMAKE+ provide improved myocardial sharpness, image quality, and rate of diagnostic quality images.