Limited physical access to target organs of patients inside an MRI scanner is a major obstruction to real-time MRI-guided interventions. Traditional teleoperation technologies are incompatible with the MRI environment and although several solutions have been explored, a versatile system that provides high-fidelity haptic feedback and access deep inside the bore remains a challenge. We present a passive and nearly frictionless MRI-compatible hydraulic teleoperator designed for in-bore liver biopsies. We describe the design components, characterize the system transparency, and evaluate the performance with a user study in a laboratory and a clinical setting. The results demonstrate <5% difference between input and output forces during realistic manipulation. A user study with participants conducting mock needle biopsy tasks indicates that a remote operator performs equally well when using the device as when holding a biopsy needle directly in hand. Additionally, MRI compatibility tests show no reduction in signal-to-noise ratio in the presence of the device.
14 July 2021 in IEEE Transactions on Medical Robotics and Bionics
We present a hydrostatic teleoperator that provides physicians remote access inside the MRI bore and enables real-time MRI guided interventions such as liver biopsies. The device consists of a custom six-axis arm and a needle insertion end effector. The manipulator is passive and backdrivable with a near one-to-one mapping of motions and forces between the input and output. The six-axis arm translates and orients the needle during insertion and passively reflects respiratory motion while maintaining contact with the skin surface. Arm joints employ novel rotary rolling-diaphragms that provide stiff and low-friction rotational motion without the need for cables, belts, or gear mechanisms found in other solutions. We perform experiments to characterize the device’s force and position tracking and demonstrate its functionality with path following tasks. Our results find a system roll-off frequency at 20Hz and that teleoperation tasks are performed comparably to holding the output directly. We motivate the need for force transparency in MRI guided biopsies with a user study in which five radiologists perform phantom membrane puncture biopsies using the needle insertion mechanism. The results indicate a 50% reduction in scans and a 14.5% decrease in membrane overshoot when force feedback is present.
23 January 2019 in IEEE Robotics and Automation Letters
We present a new rolling diaphragm actuator for transmitting forces in a teleoperated system. The initial application is for MR-guided biopsy procedures, providing accurate transmission of motions and forces between the fingertips of a physician and a biopsy needle being inserted into tissue. Desirable actuator qualities include low hysteresis, high axial stiffness, and long travel. The actuator uses an anisotropic laser-patterned fabric embedded in a soft silicone sleeve for a combination of low stretch in the axial direction and sufficient stretch in the radial direction so that a taper is not required; hence the actuator can have almost any length. We present results for a prototype input/output system with 6 cm stroke, 1 cm diameter and a minimum force of 0.3N to initiate motion. We compare its performance to a system using commercial rolling diaphragm actuators and show that the new system provides an improved combination of long stroke, high stiffness, and accurate transmission of fingertip forces.
Tactile sensing can improve end-effector control and grasp quality, especially for free-flying robots where target approach and alignment present particular challenges. However, many current tactile sensing technologies are not suitable for the harsh environment of space. We present a tactile sensor that measures normal and biaxial shear strains in the pads of a gripper using a single optical fiber with Bragg grating (FBG) sensors. Compared to conventional wired solutions, the encapsulated optical fibers are immune to electromagnetic interference — critical in the harsh environment of space. Sampling is possible at over 1 kHz to detect dynamic events. We mount sensor pads on a custom two-fingered gripper with independent control of the distal and proximal phalanges, allowing for grip readjustment based on sensing data. Calibrated sensor data for forces match those from a commercial multiaxial load cell with an average 96.2% RMS for all taxels. We demonstrate the gripper on tasks motivated by the Astrobee free-flying robots in the International Space Station (ISS): gripping corners, detecting misaligned grasps, and improving load sharing over the contact areas in pinch grasps.
Annuloplasty ring choice and design are critical to the long-term efficacy of mitral valve (MV) repair. DynaRing is a selectively compliant annuloplasty ring composed of varying stiffness elastomer segments, a shape-set nitinol core, and a cross diameter filament. The ring provides sufficient stiffness to stabilize a diseased annulus while allowing physiological annular dynamics. Moreover, adjusting elastomer properties provides a mechanism for effectively tuning key MV metrics to specific patients. We evaluate the ring embedded in porcine valves with an ex-vivo left heart simulator and perform a 150 million cycle fatigue test via a custom oscillatory system. We present a patient-specific design approach for determining ring parameters using a finite element model optimization and patient MRI data. Ex-vivo experiment results demonstrate that motion of DynaRing closely matches literature values for healthy annuli. Findings from the patient-specific optimization establish DynaRing's ability to adjust the anterior–posterior and intercommissural diameters and saddle height by up to 8.8%, 5.6%, 19.8%, respectively, and match a wide range of patient data.