MohammadSadegh KhajueeZadeh

MohammadSadegh KhajueeZadeh

Auto-generated profile, based on publicly available information

MohammadSadegh KhajueeZadeh

Electrical Engineering Department, Sharif University of Technology, Tehran, Iran

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 August 2023 in IEEE Access
Verified
Journal Article
Open access
RTReza Takarli
Reza Takarli
AAAli Amini
Ali Amini
MKMohammadsadegh Khajueezadeh
Mohammadsadegh Khajueezadeh
MZMohammad Shadnam Zarbil
Mohammad Shadnam Zarbil
AVAbolfazl Vahedi
Abolfazl Vahedi
Jorma KyyräJorma Kyyrä
Jorma Kyyrä
Finding efficient and satisfactory energy storage systems (ESSs) is one of the main concerns in the industry. Flywheel energy storage system (FESS) is one of the most satisfactory energy storage which has lots of advantages such as high efficiency, long lifetime, scalability, high power density, fast dynamic, deep charging, and discharging capability. The above features are necessary for electric vehicles (EVs), railways, renewable energy systems, and microgrids. Also, electrical machines, power electronics converters, and control systems are the cores of energy transfer in FESS. Therefore, they have a critical role in determining efficiency, power rating, power factor, cost, angular velocity, and volume of FESS. So, in this study, the FESS configuration, including the flywheel (rotor), electrical machine, power electronics converter, control system, and bearing are reviewed, individually and comprehensively. Additionally, the mentioned components have been categorized to be a guide for future research. The investigated electrical machines are compared by Finite Element Analysis (FEA). Subsequently, our laboratory’s measurement results are reviewed experimentally showing the progress in the field of FESS, such as designing robust control algorithms and an Interior Permanent Magnet-Synchronous Reluctance Machine (IPM-SynRM) to use in FESS.

3 October 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MKM. S. Khajueezadeh
M. S. Khajueezadeh
SFSajjad Feizhoseini
Sajjad Feizhoseini
ZNZ. Nasiri-Gheidari
Z. Nasiri-Gheidari
MBMehdi Behzad
Mehdi Behzad
Since any error in the rotor angle caused by the resolver affects the entire PMSM control drive system, it is necessary to investigate its effect on mechanical vibrations. Torsional vibration is accordingly considered in the following study. Thereby, firstly, the effect of resolver errors on the harmonic content of motor current and subsequently Torque Ripple (TR) was investigated. Then, dynamical modeling is done for the generator-motor-resolver set to get the mechanical Frequency Response (FR) resulting from the resolver errors. Based on the above modeling, the Dynamic Equations (DEQ) of the system were derived, and the mechanical characteristics of the set, including natural frequency values and mode shapes, were extracted. Thereafter TR was employed in the DEQs, and the mechanical FR caused by the resolver error was obtained. Eventually, comparing mechanical FR with electrical FR was done according to diagnosis superiority. All analyzes were done using experimentally verified models.

11 July 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MKM. S. KhajueeZadeh
M. S. KhajueeZadeh
MEM. Emadaleslami
M. Emadaleslami
FTF. Tootoonchian
F. Tootoonchian
ADA. Daniar
A. Daniar
MGM. C. Gardner
M. C. Gardner
BAB. Akin
B. Akin
Accurate position feedback from a resolver is highly critical for high-performance field-oriented control (FOC) drives, and eccentricity in resolvers negatively affects the drive performance. The current unbalance intensity (CUI) of permanent magnet synchronous motors (PMSM) is a known criterion to evaluate drive stability and can be caused by position feedback error. In this paper, the eccentric resolver operation is comprehensively investigated, and the corresponding CUI is analytically evaluated. Accordingly, the error limit is defined for an acceptable operation under eccentricity without derating the motor control. For this purpose, the relationship between the (a) resolver’s physical geometry, (b) magnitude and the angle of the stator current, and (c) resolver accuracy are presented through surrogate modeling. Using the proposed analytical current model, the resolver geometry is updated in order to improve the eccentricity tolerance and accuracy and lower the CUI. An optimized rotor design is built, and its accuracy and effect on CUI mitigation are experimentally verified.

15 July 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MKMohammadSadegh KhajueeZadeh
MohammadSadegh KhajueeZadeh
HSHamid Saneie
Hamid Saneie
ZNZahra Nasiri-Gheidari
Zahra Nasiri-Gheidari
Resolver is an electromagnetic position sensor typically used in the closed-loop control of permanent magnet synchronous motors (PMSMs). In terms of structure and principle of operation, resolvers are very similar to electrical machines. In this regard, different numerical and analytical models have been developed for the performance prediction of a resolver, with a compromise between computational burden and accuracy. Therefore, a fast and accurate hybrid model of the resolver is presented in this article, which can be used for resolvers with different structures. Additionally, this model can easily be implemented in software such as MATLAB/SIMULINK. The performance of different variable reluctance (VR) and wound rotor (WR) resolvers calculated from the model and finite element analysis (FEA) is compared to show the value of the proposed model. The model is also used to improve the position determination accuracy of a VR resolver. Finally, a prototype of the optimized resolver is used for experimental tests to confirm the validity of the analysis.

24 July 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MEMahdi Emadaleslami
Mahdi Emadaleslami
MKMohammadSadegh KhajueeZadeh
MohammadSadegh KhajueeZadeh
FTFarid Tootoonchian
Farid Tootoonchian
Static eccentricity in the resolver, with higher probability and severity occurrence, gradually injects instability into the drive system; thus, its exact location diagnosis is mandatory. Whereas most existing investigations rely on frequency analysis of signal voltages for resolver fault diagnosis, artificial intelligence (AI) is at the center of attention for electric motors fault diagnosis. Yet, sufficient data collection brings some challenges for AI. Therefore, intrigued by the idea of few-shot learning to overcome the data scarcity challenge, a Convolutional Neural Siamese network is employed with limited data to diagnose the static eccentricity location under each stator tooth via raw signal voltages, which is ordinarily employed for rotor angle extraction. Accordingly, a Siamese network learns to yield the probability of signal pairs being similar by distance unit. A lab-built Time-Stepping Finite Element Analysis (TS-FEA) and a resolver test-bench dataset under different training sizes, noise existence, and new unseen locations challenges are employed to assess the employed Siamese network. Comparing the employed Siamese network with One Dimension-Convolutional Neural Network (1D-CNN) shows its proficiency and superiority.

15 December 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MKMohammadSadegh KhajueeZadeh
MohammadSadegh KhajueeZadeh
FZFateme Zare
Fateme Zare
ZNZahra Nasiri-Gheidari
Zahra Nasiri-Gheidari
The existence of resolvers in the Two Degree of Freedom (2DOF) control algorithm is mandatory due to their improved performance in harsh environments. However, resolver’s errors significantly influence the control system’s stability. Therefore, it is required to comprehensively investigate the resolver’s reliability under fault conditions. In this regard, an employed assessment model is presented. Subsequently, the failure modes in the 2DOF and One Degree of Freedom (1DOF) resolvers’ configurations are investigated thoroughly. Among the methods used to assess reliability, the Markov model is chosen for the reliability analyses. After meeting all of the above, the faulty conditions are injected into the resolvers’ configurations by using Finite Elements Analysis (FEA). The measurement of resolvers’ accuracy under the above conditions is done. Accordingly, the reliability metrics are chosen appropriately to define the reliability state of the resolver. Comparing the reliability is done numerically between a 2DOF integrated resolver and two 1DOF resolvers. Finally, examinations are done practically to show the accuracy status of the resolvers under faulty conditions. The outcomes can be used as a guide to optimally choose the resolvers’ configuration in 2DOF controls.