Aidan Dominic Roche

Aidan Dominic Roche

Auto-generated profile, based on publicly available information

Aidan Dominic Roche

College of Medicine and Veterinary Medicine, The Queen's Medical Research Institute, The University of Edinburgh, Edinburgh, United Kingdom

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 January 2014 in Current Surgery Reports
Verified
Journal Article
Closed access
PDF file
ARAidan D. Roche
Aidan D. Roche
HRHubertus Rehbaum
Hubertus Rehbaum
DFDario Farina
Dario Farina
OAOskar C. Aszmann
Oskar C. Aszmann

1 May 2015 in The Lancet
Verified
Journal Article
Closed access
OAOskar C. Aszmann
Oskar C. Aszmann
ARAidan D Roche
Aidan D Roche
SSStefan Salminger
Stefan Salminger
TPTatjana Paternostro-Sluga
Tatjana Paternostro-Sluga
MHMalvina Herceg
Malvina Herceg
DFDario Farina
Dario Farina

17 July 2019 in Science Robotics
Verified
Journal Article
Closed access
PDF file
SSS. Salminger
S. Salminger
Agnes SturmaAgnes Sturma
Agnes Sturma
CHC. Hofer
C. Hofer
MEM. Evangelista
M. Evangelista
MPM. Perrin
M. Perrin
OAOskar C. Aszmann
Oskar C. Aszmann
The use of implantable myoelectric sensors showed substantial improvements in prosthetic function of above-elbow amputees.

9 July 2015 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
SASebastian Amsuess
Sebastian Amsuess
IVIvan Vujaklija
Ivan Vujaklija
PGPeter Goebel
Peter Goebel
ARAidan D. Roche
Aidan D. Roche
BGBernhard Graimann
Bernhard Graimann
DFDario Farina
Dario Farina
Pattern recognition and regression methods applied to the surface EMG have been used for estimating the user intended motor tasks across multiple degrees of freedom (DOF), for prosthetic control. While these methods are effective in several conditions, they are still characterized by some shortcomings. In this study we propose a methodology that combines these two approaches for mutually alleviating their limitations. This resulted in a control method capable of context-dependent movement estimation that switched automatically between sequential (one DOF at a time) or simultaneous (multiple DOF) prosthesis control, based on an online estimation of signal dimensionality. The proposed method was evaluated in scenarios close to real-life situations, with the control of a physical prosthesis in applied tasks of varying difficulties. Test prostheses were individually manufactured for both able-bodied and transradial amputee subjects. With these prostheses, two amputees performed the Southampton Hand Assessment Procedure test with scores of 58 and 71 points. The five able-bodied individuals performed standardized tests, such as the box&block and clothes pin test, reducing the completion times by up to 30%, with respect to using a state-of-the-art pure sequential control algorithm. Apart from facilitating fast simultaneous movements, the proposed control scheme was also more intuitive to use, since human movements are predominated by simultaneous activations across joints. The proposed method thus represents a significant step towards intelligent, intuitive and natural control of upper limb prostheses.

2 September 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SSStefan Salminger
Stefan Salminger
ASAgnes Sturma
Agnes Sturma
ARAidan D. Roche
Aidan D. Roche
LHLaura A. Hruby
Laura A. Hruby
TPTatjana Paternostro-Sluga
Tatjana Paternostro-Sluga
OAOskar C. Aszmann
Oskar C. Aszmann
Hand-transplantation and improvements in the field of prostheses opened new frontiers in restoring hand function in below-elbow amputees. Both concepts aim at restoring reliable hand function, however, the indications, advantages and limitations for each treatment must be carefully considered depending on level and extent of amputation. Here we report our findings of a multi-center cohort study comparing hand function and quality-of-life of people with transplanted versus prosthetic hands. Hand function in amputees with either transplant or prostheses was tested with Action Research Arm Test (ARAT), Southampton Hand Assessment Procedure (SHAP) and the Disabilities of the Arm, Shoulder and Hand measure (DASH). Quality-of-life was compared with the Short-Form 36 (SF-36). Transplanted patients (n = 5) achieved a mean ARAT score of 40.86 ± 8.07 and an average SHAP score of 75.00 ± 11.06. Prosthetic patients (n = 7) achieved a mean ARAT score of 39.00 ± 3.61 and an average SHAP score of 75.43 ± 10.81. There was no significant difference between transplanted and prosthetic hands in ARAT, SHAP or DASH. While quality-of-life metrics were equivocal for four scales of the SF-36, transplanted patients reported significantly higher scores in “role-physical” (p = 0.006), “vitality” (p = 0.008), “role-emotional” (p = 0.035) and “mental-health” (p = 0.003). The indications for hand transplantation or prosthetic fitting in below-elbow amputees require careful consideration. As functional outcomes were not significantly different between groups, patient’s best interests and the route of least harm should guide treatment. Due to the immunosuppressive side-effects, the indication for allotransplantation must still be restrictive, the best being bilateral amputees.

22 February 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
TKTamás Kapelner
Tamás Kapelner
NJNing Jiang
Ning Jiang
AHAleš Holobar
Aleš Holobar
IVIvan Vujaklija
Ivan Vujaklija
ARAidan D. Roche
Aidan D. Roche
OAOskar C. Aszmann
Oskar C. Aszmann
Targeted muscle reinnervation (TMR) is a surgical procedure used to redirect nerves originally controlling muscles of the amputated limb into remaining muscles above the amputation, to treat phantom limb pain and facilitate prosthetic control. While this procedure effectively establishes robust prosthetic control, there is little knowledge on the behavior and characteristics of the reinnervated motor units. In this study we compared the m. pectoralis of five TMR patients to nine able-bodied controls with respect to motor unit action potential (MUAP) characteristics. We recorded and decomposed high-density surface EMG signals into individual spike trains of motor unit action potentials. In the TMR patients the MUAP surface area normalized to the electrode grid surface (0.25 ± 0.17 and 0.81 ± 0.46, p < 0.001) and the MUAP duration (10.92 ± 3.89 ms and 14.03 ± 3.91 ms, p < 0.01) were smaller for the TMR group than for the controls. The mean MUAP amplitude (0.19 ± 0.11 mV and 0.14 ± 0.06 mV, p = 0.07) was not significantly different between the two groups. Finally, we observed that MUAP surface representation in TMR generally overlapped, and the surface occupied by motor units corresponding to only one motor task was on average smaller than 12% of the electrode surface. These results suggest that smaller MUAP surface areas in TMR patients do not necessarily facilitate prosthetic control due to a high degree of overlap between these areas, and a neural information—based control could lead to improved performance. Based on the results we also infer that the size of the motor units after reinnervation is influenced by the size of the innervating motor neuron.