This paper presents the results of the study of the composite based on magnesium hydride with the addition of nanosized nickel powder, obtained by the method of an electric explosion of wires. The obtained MgH2-EEWNi (20 wt.%) composite with the core-shell configuration demonstrated the development of a defect structure, which makes it possible to significantly reduce the hydrogen desorption temperature from 418 °C for pure magnesium hydride to 229 °C for hydride with the addition of nickel powder. In situ studies of the evolution of the defect structure using positron annihilation methods and diffraction methods made it possible to draw conclusions about the influence of the Mg2NiH0.3 and Mg2NiH4 phases on the sorption and desorption properties of the composite. The results obtained in this work can be used in the field of hydrogen energy in mobile or stationary hydrogen storage systems.
The current work is devoted to developing a system for the complex research of metal–hydrogen systems, including in an in situ mode. The system consists of a controlled gas reactor with a unique reaction chamber, a radioisotope positron source, and a positron annihilation spectroscopy complex. The use of the system enables in situ investigation of the defect structure of solids in hydrogen sorption–desorption processes at temperatures up to 900 °C and pressures up to 50 bar. Experimental investigations of magnesium and magnesium hydride during thermal annealing were carried out to approve the possibilities of the developed complex. It was shown that one cycle of magnesium hydrogenation–dehydrogenation resulted in the accumulation of irreversible hydrogen-induced defects. The defect structure investigation of the magnesium–hydrogen system by positron annihilation techniques was supplemented with a comprehensive study by scanning electron microscopy, X-ray diffraction analysis, and hydrogen sorption–desorption studies.
This work aims to investigate the 64Cu isotope applicability for positron annihilation experiments in in situ mode. We determined appropriate characteristics of this isotope for defect studies and implemented them under aggressive conditions (i.e., elevated temperature, hydrogen environment) in situ to determine the sensitivity of this approach to thermal vacancies and hydrogen-induced defects investigation. Titanium samples were used as test materials. The source was obtained by the activation of copper foil in the thermal neutron flux of a research nuclear reactor. Main spectrometric characteristics (e.g., the total number of counts, fraction of good signals, peak-to-noise ratio) of this source, as well as line-shaped parameters of the Doppler broadening spectrum (DBS), were studied experimentally. These characteristics for 64Cu (in contrast to positron sources with longer half-life) were shown to vary strongly with time, owing to the rapidly changing activity. These changes are predictable and should be considered in the analysis of experimental data to reveal information about the defect structure. The investigation of samples with a controlled density of defects revealed the suitability of 64Cu positron source with an activity of 2–40 MBq for defects studies by DBS. However, greater isotope activity could also be applied. The results of testing this source at high temperatures and in hydrogen atmosphere showed its suitability to thermal vacancies and hydrogen-induced defects studies in situ. The greatest changes in the defect structure of titanium alloy during high-temperature hydrogen saturation occurred at the cooling stage, when the formation of hydrides began, and were associated with an increase in the dislocation density.
22 November 2024 in Journal of Engineering Physics and Thermophysics
The narrow fraction of the cenospheres of coal fly ash (30−50 μm; glass phase ∼ 90 wt. %) was used for the preparation of β‐emitting 177Lu‐bearing aluminosilicate microspheres. Two methods of chemical modification to encapsulate 177Lu3+ in the cenosphere’s aluminosilicate matrix were used, such as the formation of (i) microporous or (ii) meso/macroporous structure in the cenosphere shell followed by 175+176Lu3+ sorption. Conversion of Lu‐loaded microspheres into poorly soluble forms was performed via the thermal treatment at 900–1200°C and then 176Lu was transformed to 177Lu by neutron activation procedure in a nuclear reactor. The 176Lu‐bearing products were studied by PXRD, SEM, and EDX spectroscopy methods. It was established that the acid treatment of cenospheres resulting in a meso/macroporous structure in the cenosphere shell is the optimal nondestructive method to produce a microsphere precursor for Lu incorporation. The neutron activation of 176Lu‐bearing microspheres resulted in 177Lu‐microspheres that provide the specific radioactivity of 4.5 GBq/100 mg. The Lu leaching rate from 177Lu‐microspheres in a blood simulator determined according to the State Standard (GOST) R 52126‐2003 was about 10−6−10−7 g/cm2⋅day.