JTJindong Tan
Jindong Tan
This paper proposes a numerical model to predict actuation frequencies (strain-cycling frequencies) for 1-D SMA actuators. The numerical model is designed by comprehensively considering the factors that significantly affect an SMA actuator's strain-cycling frequency, i.e. heat convection methods, constant or non-constant bias loads, and Joule heating methods. For computing strain cycles of SMA actuators, we develop a computation framework that effectively integrates an SMA constitutive model, a phase transformation kinetic model, stress-strain models for different types of bias stress, and a heat transfer model of SMA wires. The strain and temperature rates are formulated by nonlinear ordinary differential equations. The strain and temperature cycles can be accurately approximated by numerical iterative methods. Experimental verification was conducted to investigate the effectiveness of the proposed model. By initially identifying the SMA characteristic parameters, we employed the Latin hypercube sampling method to generate 30 sets of design parameters for comparing the predicted and measured actuation frequencies. In addition, we investigated how the uncertainty of pre-measured SMA characteristic parameters affect the numerical prediction of actuation frequency by conducting sensitivity analysis. The experiments demonstrate 0.7%~9.03% and 2.65%~17.57% differences between predicted and measured actuation frequencies for constant bias loads and spring bias loads respectively.

29 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
NLNing Li
Ning Li
HLHui Liu
Hui Liu
RAReza Yazdanpanah Abdolmalaki
Reza Yazdanpanah Abdolmalaki
GMGregory J. Mancini
Gregory J. Mancini
JTJindong Tan
Jindong Tan
Fully insertable robotic imaging devices represent a promising future of minimally invasive laparoscopic vision. Emerging research efforts in this field have resulted in several proof-of-concept prototypes. One common drawback of these designs derives from their clumsy tethering wires which not only cause operational interference but also reduce camera mobility. In this paper, a tetherless insertable surgical camera (s-CAM) robot with non-contact transabdominal actuation is presented for single-incision laparoscopic vision. Wireless video transmission and control communication using onboard power help eliminate cumbersome tethering wires. Furthermore, magnetic based camera actuation gets rid of intrinsic physical constraints of mechanical driving mechanisms, thereby improving camera mobility and reducing operational interference. In addition, a custom Bluetooth low energy (BLE) application profile and a real-time operating system (RTOS) based multitask programming framework are also proposed to facilitate embedded software design for insertable medical devices. Initial ex vivo test results of the s-CAM design have demonstrated technical feasibility of a tetherless insertable laparoscopic camera. Effective imaging is confirmed at as low as 500 lx illumination. Wireless laparoscopic vision is accessible within a distance of more than 10 m. Transabdominal BLE communication is stable at over −52 dBm and shows its potential for wireless control of insertable medical devices. RTOS based sfotware event response is bounded within 1 ms while the CPU usage is at 3∼5%. The device is able to work for 50 min with its onboard power. For the mobility, the robot can translate against the interior abdominal wall to reach full abdomen quadrants, tilt between −180∘ and +180∘, and pan in the range of 0∘∼360∘. The s-CAM has brought robotic laparoscopic imaging one step further toward less invasiveness and more dexterity.

18 April 2024 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
HLHui Liu
Hui Liu
NLNing Li
Ning Li
SLShuai Li
Shuai Li
GMGregory J. Mancini
Gregory J. Mancini
JTJindong Tan
Jindong Tan
In single-incision laparoscopic surgery (SILS), magnetic anchoring and guidance system (MAGS) is a promising technique to prevent clutter in the surgical workspace and provide a larger vision field. Existing camera designs mainly rely on a rigid structure and sliding motion, which may cause stress concentration and tissue damage on curved abdominal walls. Meanwhile, the insertion procedure is also challenging. In this paper, we proposed a wireless MAGS consisting of soft material and wheel structure design. The camera can passively bend and adapt to the curved tissue surface to relieve stress concentration. The wheel structure transfers the sliding motion to rolling motion when the camera tilts and translates, avoiding tissue rupture due to dry friction and facilitating smooth motion. The experiments show the novel laparoscope has dexterous locomotion and bendability with 20∘ in bending angle and 16.4mm in displacement. The maximum stress is reduced by 64% compared with rigid designs. An easy and safe insertion procedure based on soft property is also introduced, which takes less than 2 minutes on average without the assistance of additional instruments.

1 May 2010 in Gastroenterology
Verified
Journal Article
Open access
HLHui Liu
Hui Liu
CSCristina Semino-Mora
Cristina Semino-Mora
NSNina Salama
Nina Salama
TBThomas Borén
Thomas Borén
ADAndré Dubois
André Dubois