Yi-Chyun Chiang

Yi-Chyun Chiang

Auto-generated profile, based on publicly available information

Yi-Chyun Chiang

Department of Electronic Engineering, Chang Gung University, Tao-yuan 333, Taiwan, R.O.C.

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2020 in IEEE Access
Verified
Journal Article
Open access
GSGuan-Ren Su
Guan-Ren Su
ELEric S. Li
Eric S. Li
TKTing-Wei Kuo
Ting-Wei Kuo
HJHuayan Jin
Huayan Jin
YCYi-Chyun Chiang
Yi-Chyun Chiang
KCKuo-Sheng Chin
Kuo-Sheng Chin
A wide-beam microstrip patch antenna and antenna array ranging from 77 to 81 GHz are presented in this study for millimeter-wave applications. A substrate-integrated-waveguide probe-fed patch was developed. For beamwidth enhancement, two I-shaped parasitic elements were placed next to the main patch to establish a three-element subarray. The current directions of the parasitic elements were opposite to that of the main patch, leading to beamwidth enhancement in the E-plane radiation pattern. The proposed I-shaped parasitic element has the advantages of coplanar structure, compact size, and easy adjustment of the induced current. An array-factor method was employed to analyze the effect of the parasitic elements on the beamwidth of the main patch. Three amplitude distributions of the subarray were compared. The distribution of –0.1:1:–0.1 was proved to present the most beamwidth, which can be realized easily by the proposed I-shaped parasitic elements. To achieve both wide beamwidth and high gain, a 1 × 8 patch antenna array with the I-shaped parasitic elements was proposed. The measured results showed that the design can offer a gain of 10.74 dBi and a wide beamwidth of 138° at 79 GHz.

8 January 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
DTDongyang Tang
Dongyang Tang
JWJing Wang
Jing Wang
WHWeibo Hu
Weibo Hu
ZPZhengyu Peng
Zhengyu Peng
YCYi-Chyun Chiang
Yi-Chyun Chiang
Changzhi LiChangzhi Li
Changzhi Li
One challenge of designing a dc-coupled biomedical radar sensor is dealing with the dc offset voltage presented in its receiver. The undesired dc offset is mainly caused by clutter reflection and hardware imperfection. It may saturate the baseband amplifier and limit the maximum dynamic range that a biomedical radar sensor can achieve. AC-coupling the signal can eliminate dc offset but it will also distort the signal, and thus may not be acceptable for high precision applications. In this paper, a dc-coupled biomedical radar sensor is proposed incorporating an analog dc offset cancelation circuit with fast start-up feature. It can automatically remove any dc offset in the baseband signal and emulates an ac-coupling system. It can also be easily reconfigured into a dc-tracking mode when application requires. When entering this mode, the initial dc offset will be removed, whereas future dc change can be recorded. The proposed solution only uses analog components without requiring any digital signal processing nor software programing. Therefore, compared with the existing digitized dc offset calibration techniques, the proposed method has the advantage of low cost, easy implementation, short delay, and high resolution. The experiment results demonstrated that a wide range of dc offset can be successfully removed from the biomedical radar sensor, and its dynamic range can be maximized. The reconfiguration of the dc-tracking mode has also been tested and verified. Furthermore, the proposed dc offset cancelation circuit has the potential to be easily adopted by other systems that also face the dc offset problem.

6 December 2017 in IEEE Microwave and Wireless Components Letters
Verified
Journal Article
Closed access
ZYZhi-Ping Yang
Zhi-Ping Yang
YCYi-Chyun Chiang
Yi-Chyun Chiang
A new type of vital signal radar with adaptive dc compensation circuits that can automatically eliminate the dc offsets caused by clutter signals without software controlled units is presented. The theoretical analysis of the dc compensation circuits, which are connected to the outputs of a direct conversion mixer will be described. A 2.5-GHz experimental prototype was fabricated on a printed circuit board substrate to verify the proposed adaptively compensated radar. All circuits are realized by commercially available devices. Measurements show very good agreement with theoretical prediction. The radar can be used with only a single antenna connected to the proposed module and have successfully detected clearly heartbeat and respiration signals at any distance within the detectable range by incorporating phase-shifting technique.

1 May 2018
Verified
Conference Paper
Closed access
DTDongyang Tang
Dongyang Tang
JWJing Wang
Jing Wang
ZPZhengyu Peng
Zhengyu Peng
YCYi-Chyun Chiang
Yi-Chyun Chiang
Changzhi LiChangzhi Li
Changzhi Li
A common problem of biomedical radar sensors is the DC offset at the output of radar receiver front-end. In this paper, a DC-coupled Doppler radar sensor system with an analog DC offset calibration circuit is proposed. The calibration circuit can track the change of DC offset continuously, and automatically remove the offset on the fly or in a controlled manner. The proposed calibration circuit uses pure analog components and does not require any digital signal processing (DSP) or software configuration. Compared to existing digitized solutions, the proposed analog calibration technique has the advantage of low cost, low complexity, extremely small delay, and very high resolution. Experiment demonstrates that input signals with a wide range of input DC offset can be processed. Hence the dynamic range of the baseband variable gain amplifier (VGA) can be maximized. Furthermore, the proposed DC offset calibration architecture can be easily adopted by other systems which also face DC offset problem.

1 January 2011 in Progress In Electromagnetics Research
Verified
Journal Article
Open access
PDF file
ZYZeu-Yuan Yeh
Zeu-Yuan Yeh
YCYi-Chyun Chiang
Yi-Chyun Chiang
This work presents a new type of CPW balun consisting of 3 dB coupled-line sections, which are one eighth wavelength long, and a short redundant transmission line for the applications of the modern wireless communication systems. A set of design equations that can determine the values of the elements of balun is proposed. A new type of coupler constructed with a structure similar to the conventional step impedance resonator is developed to further reduce the size of the balun. An experimental prototype operated at 1.0 GHz was designed and fabricated to verify the proposed design method. The measurement results show quite good correspondences with the theoretical predictions and the EM simulations.

1 August 2005 in Solid-State Electronics
Verified
Journal Article
Closed access
HCHsien-Chin Chiu
Hsien-Chin Chiu
YCYi-Chyun Chiang
Yi-Chyun Chiang
CWChan-Shin Wu
Chan-Shin Wu